Nabertherm VL 01/12 LB
Nabertherm VL 01/12 LB — Dental firing & pressing furnaces.
The VL 01/12 LB is a single-phase vacuum firing furnace with a 70 mm work space and 1200 °C maximum temperature, built for dental ceramic firing. Its 1.8 kW nominal power and 10-minute heating time distinguish it within the series as a compact, fast-ramp unit. It integrates into dental labs as a standalone programmable station controlled by the D580 controller.
Full specifications
| Electrical connection | 1-phase |
| Nominal power | 1.8 kW |
| Work space dimensionsin mm mfr | 70 |
| Work space dimensionsin mm mfr | 70 |
| Heating time mfr | 10 min |
| Outer dimensions (W × D × H) mfr | 360 × 605 mm |
| Weight | 22 kg |
| Charging areain mm mfr | 70 |
| Max temperature | 1200 °C |
Description
Construction and series positioning
- The VL 01/12 LB is a lifting-table vacuum firing furnace: the work space is 70 mm in each dimension, and the charging area is also 70 mm.
- Outer dimensions are 360 × 605 mm (W × D × H), and the unit weighs 22 kg.
- No sibling models are listed in the verified facts, so positioning within the series cannot be stated beyond the model code itself.
Thermal and electrical behavior
- Maximum temperature is 1200 °C; nominal power is 1.8 kW on a 1-phase electrical connection.
- Heating time is given as 10 min; no curve points are available to describe load-dependent ramp behavior.
- No vacuum level, atmosphere, or cooling-rate data is present in the verified facts, so media behavior cannot be characterized.
Control and operation
- The attached controller digest covers the D580 controller for vacuum firing and vacuum pressing furnaces in dental ceramics, Wi-Fi-capable and compatible with the MyNabertherm App.
- The process-control digest covers Nabertherm controller series 500 and the MyNabertherm app, including process data storage and temperature uniformity/AMS2750F instrumentation types.
- No installation, connection, or operating specifics for this furnace model are present in the document digests.
Integration & Operating Notes
The furnace is a 1-phase unit rated 1.8 kW; the branch circuit and protective device must be selected for this load. No voltage or current value is stated in the verified facts, so the actual supply voltage must be confirmed before installation.
The controller digest identifies the D580 as Wi-Fi-capable and compatible with the MyNabertherm App for vacuum firing and vacuum pressing furnaces in dental ceramics. Network availability and app pairing should be planned if remote process monitoring is required.
Both the work space dimensions and the charging area are 70 mm, so dental ceramic parts and any firing trays must fit within this envelope. Oversized charges will not seat on the lifting table and can disturb the firing position.
The maximum temperature is 1200 °C. Firing programs for dental ceramics must be written so that setpoints and any overshoot remain at or below this limit; no separate safety-temperature margin is stated in the verified facts.
The attached document digests contain no service schedule, error-code list, or consumable replacement interval for this furnace. Maintenance planning must therefore be based on the separate operating manual, which is not part of the verified facts.
Selection & Integration Q&A
Choose it when the firing chamber must fit within a 70 mm work space and charging area and the process stays at or below 1200 °C. No sibling models are listed in the verified facts, so a direct comparison with other series members cannot be made from this data.
It is a 1-phase, 1.8 kW unit; the exact voltage and current are not stated in the verified facts and must be confirmed before wiring. Control is via the D580 controller, which is Wi-Fi-capable and works with the MyNabertherm App.
The verified document digests contain no maintenance schedule, error codes, or accessory list for this model. Cables, firing trays, and consumables are therefore not confirmed as included or excluded; the separate operating manual must be consulted.