Shimadzu Combustion ION Chromatography System
Shimadzu Combustion ION Chromatography System — Chromatographs.
The Combustion Ion Chromatography System couples a Shimadzu Nexera IC ion chromatograph with a Nittoseiko Analytech AQF-5000H Automatic Quick Furnace to measure halogen and sulfur content in liquid or solid samples. It supports the Adsorbable Organic Fluorine (AOF) method and can be equipped with an optional ES-500 external liquid selector for six standard solutions. This integrated configuration is intended for automated combustion IC analysis in a laboratory setting.
Direct drop-in replacements
Full specifications
| Type | Combustion Ion Chromatography System |
| Ion chromatograph mfr | Nexera IC |
| Automatic quick furnace mfr | AQF-5000H |
| Sample types mfr | liquid or solid |
| Analytes mfr | halogen and sulfur content |
| AOF analysis mfr | Adsorbable Organic Fluorine (AOF) method |
| Optional external liquid selector mfr | ES-500 |
| Number of standard solutions switchable (ES-500) (ES-500 optional) mfr | six (ES-500 optional) |
Description
Construction and configuration
- The system is a two-module assembly: a Nexera IC ion chromatograph for separation and detection, and an AQF-5000H Automatic Quick Furnace for combustion of liquid or solid samples.
- The AQF-5000H furnace is the sample-introduction front end; the Nexera IC handles the chromatographic separation and quantification of halogens and sulfur.
- An optional ES-500 external liquid selector extends automation by allowing selection among six standard solutions.
Analytical scope
- The system is configured for the determination of halogen and sulfur content.
- It supports the Adsorbable Organic Fluorine (AOF) method, making it suitable for AOF analysis in addition to total halogen and sulfur measurements.
- Sample types accepted are liquid or solid, with combustion occurring in the AQF-5000H prior to IC analysis.
Operation and integration
- The two instruments operate as a coupled system; combustion products from the furnace are transferred to the ion chromatograph for separation and detection.
- The ES-500, when present, adds automated standard-solution selection, reducing manual intervention for calibration and quality-control runs.
- No further installation, control, or maintenance details are available from the supplied document digest.
Integration & Operating Notes
The system accepts liquid or solid samples, but the combustion step in the AQF-5000H and the subsequent IC separation impose matrix constraints. Verify that sample composition and analyte concentration fall within the working range of both modules before routine analysis.
The ES-500 external liquid selector is an optional accessory that provides switching among six standard solutions. If automated calibration and QC are required, the ES-500 must be specified at the time of order; it is not part of the base configuration.
Because the system comprises two independent instruments (Nexera IC and AQF-5000H), maintenance intervals and consumables are defined separately for each module. Refer to the respective instruction manuals for the ion chromatograph and the automatic quick furnace.
Selection & Integration Q&A
Choose this system when halogen or sulfur content must be determined in solid or liquid samples that require combustion prior to IC analysis. A standalone IC cannot handle solid matrices or total halogen/sulfur measurements without the AQF-5000H furnace.
The two modules are supplied as a coupled system; combustion products from the AQF-5000H are transferred to the Nexera IC for separation. Installation and connection details are covered in the respective instruction manuals; no additional interface specifications are provided in the supplied digest.
The system accepts liquid or solid samples and is configured for the determination of halogen and sulfur content. It also supports the Adsorbable Organic Fluorine (AOF) method for AOF analysis.
The ES-500 external liquid selector enables automated switching among six standard solutions. It is an optional accessory and is not included in the base delivery; it must be ordered separately.