Shimadzu EPMA-1720
Shimadzu ·Made in Japan · In Active Production

Shimadzu EPMA-1720

Shimadzu EPMA-1720 — Elemental analyzers.

The EPMA-1720 is a wavelength-dispersive electron probe microanalyzer with a 52.5° X-ray take-off angle and up to five 4-inch spectrometers, delivering >30% higher sensitivity than prior configurations. It uses a thermionic electron source (CeB6 in the HT variant) and is intended for quantitative elemental mapping and phase analysis of solid geological, metallurgical, and materials samples.

Full specifications

Core Performance & Functional Specifications
X-ray take-off angle (EPMA-1720 Series) mfr 52.5 ° (EPMA-1720 Series)
Number of spectrometers (EPMA-1720, 4-inch spectrometers) mfr up to five (EPMA-1720, 4-inch spectrometers)
Spectrometer crystal size mfr 4 inch (EPMA-1720)
Sensitivity increase (EPMA-1720 Series) mfr more than 30 % (EPMA-1720 Series)
Electron source (EPMA-1720HT) mfr CeB6 (EPMA-1720HT)
Electrical, Power & Drive Specifications
Sample current (example setting) mfr 10 nA (example setting)

Description

Construction and series positioning

Behavior under load and in operation

Installation, connection, and control

Integration & Operating Notes

Process Limits
Fixed 52.5° take-off angle constrains spectrometer geometry

All wavelength-dispersive measurements are made at a single 52.5° take-off angle; analysts cannot vary this geometry to optimize for light elements or thin films, so method development must use standards and correction models matched to this fixed configuration.

Factory Specification Sheet, EPMA-1720 Series

Selection & Integration Q&A

When should I choose the EPMA-1720 instead of the EPMA-1720HT variant?

Choose the base EPMA-1720 when a conventional thermionic source is acceptable and CeB6 brightness/lifetime is not required. Select the EPMA-1720HT when the CeB6 cathode's higher brightness and longer service interval justify the variant; both share the 52.5° take-off angle and up to five 4-inch spectrometers.

What adjacent system requirements must be confirmed before ordering the EPMA-1720?

Confirm vacuum-pumping capacity and floor space for up to five 4-inch spectrometers, and obtain the page-30 specification sheet for electrical supply and control-interface details, since the supplied brochure digest does not list them.

What duty-cycle or environmental limits apply to the EPMA-1720?

The supplied facts do not state duty-cycle, ambient temperature, humidity, or cooling requirements; these are referenced to page 30 of the brochure, which was not provided. Confirm them with Shimadzu before committing to continuous mapping campaigns.

What maintenance and consumables are needed beyond the base delivery?

The EPMA-1720HT requires periodic CeB6 cathode replacement; the base EPMA-1720 uses a different thermionic source. Spectrometer crystals, electron-source filaments, and vacuum consumables are not listed in the supplied facts and must be quoted separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Element Mapping of Volcanic Rock from Mt. Asama - Electron Probe Microanalyzer
Datasheet ·3,9 МБ ·3 pp.
View PDF
PDF
c143-e012
Datasheet ·6,5 МБ ·32 pp.
View PDF