Shimadzu Nexera Series
Shimadzu ·Made in Japan · In Active Production

Shimadzu Nexera Series

Shimadzu Nexera Series — Chromatographs.

The Shimadzu Nexera Series is a dual-pump UHPLC system engineered for high-pressure separations up to 130 MPa, accommodating columns with 1–3 mm I.D. and sub-2–3 μm particles. Its standard multi-rinse feature distinguishes it for sensitive, high-throughput analyses. It serves as the core solvent delivery and sample injection module in demanding chromatographic workflows.

Direct drop-in replacements

0%
match
⚖️ Compare
0%
match
⚖️ Compare

Full specifications

Description

Construction and Series Positioning

The Nexera Series is built around a dual-pump architecture, enabling binary or ternary gradient operation with independent flow control. This model is specified for maximum system pressure of 130 MPa, supporting columns packed with sub-2–3 μm particles and internal diameters of 1–3 mm. Within the series, the Nexera XS inert variant offers a pressure capacity of 105 MPa, making this standard model the higher-pressure option for conventional stainless-steel flow paths. The inclusion of multi-rinse as standard reduces carryover in high-sensitivity applications. ### Hydraulic and Separation Behavior

Operating at up to 130 MPa allows the use of small-particle columns for rapid, high-resolution separations. The dual-pump design maintains precise gradient composition under these pressures, though the inert pressure limit of 105 MPa applies to the XS inert configuration, not this model. The system requires appropriate laboratory infrastructure for high-pressure operation, including compatible tubing and fittings rated for 130 MPa.

Integration & Operating Notes

Process Limits
Do not exceed 130 MPa system pressure

Exceeding the maximum pressure rating of 130 MPa can cause seal failure, tubing rupture, or column damage. Always verify that the column and all connecting fittings are rated for the operating pressure, and use pressure ramping during method development to avoid sudden overpressure.

Factory Specification Sheet
Maintenance
Multi-rinse is standard; ensure rinse solvent compatibility

The installed multi-rinse feature requires a compatible rinse solvent that does not precipitate or degrade under the high-pressure conditions. Regularly check rinse solvent levels and replace as needed to prevent carryover and maintain injection precision.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this Nexera model over the Nexera XS inert variant?

Choose this model when maximum pressure up to 130 MPa is needed for conventional stainless-steel columns. The XS inert variant is limited to 105 MPa but offers inert flow path for sensitive analytes; select it if bio-inertness is critical and pressures stay below 105 MPa.

What are the requirements for connecting a column to this system?

Ensure the column and fittings are rated for at least 130 MPa and compatible with 1–3 mm I.D. columns. Use appropriate tubing and connectors to avoid leaks or pressure drops. The system’s dual pumps require proper priming and degassing before connection.

Dimensional Drawings & Technical Documentation

Technical documentation