Shimadzu Tescan Amber X 2

Shimadzu Tescan Amber X 2 — Microscopes.

The Tescan Amber X 2 is a plasma FIB-SEM (PFIB) that combines a BrightBeam field-free UHR SEM column with a Mistral Xe+ plasma ion source for site-specific sample preparation and 3D tomography. It supports EDS, EBSD, and ToF-SIMS detectors and enables TEM lamella preparation via TEM AutoPrep Pro. The system is controlled by Tescan Essence software and is suited for multi-modal materials characterization in a single instrument.

Full specifications

Description

Construction and positioning

Integration & Operating Notes

Mounting
Site planning must account for vibration and EMI isolation

High-resolution SEM and FIB columns are sensitive to mechanical vibration and electromagnetic interference; the installation site should be evaluated for floor vibration and stray fields, and the instrument may require a dedicated anti-vibration foundation or active isolation system as specified in the site preparation manual.

Site Preparation Guide (not provided in digests
Electrical
Stable power with low harmonic distortion is required

The system includes high-voltage supplies for the SEM and plasma FIB, and sensitive detectors; power quality should meet the manufacturer's specifications for voltage stability, harmonic distortion, and grounding to avoid image artifacts or equipment damage.

Electrical Requirements (not provided in digests
Control & I/O
Essence software integrates column and detector control

All acquisition and processing functions are controlled through Tescan Essence software, which coordinates the SEM and FIB columns, stage, and detectors; users should verify compatibility with existing data management and network infrastructure.

Software Overview (not provided in digests
Process Limits
Xe+ plasma source requires specific gas supply and purity

The Mistral plasma FIB uses xenon gas; the supply must be of high purity and delivered at the pressure and flow rate specified by the manufacturer to maintain stable plasma and prevent contamination of the ion column.

Gas Supply Requirements (not provided in digests
Maintenance
Regular column maintenance ensures consistent performance

The SEM and FIB columns require periodic alignment, aperture cleaning, and detector calibration as outlined in the maintenance schedule; consumables such as apertures, filaments (if applicable), and gas filters should be stocked according to the recommended service intervals.

Maintenance Manual (not provided in digests

Selection & Integration Q&A

When should I choose the Amber X 2 over a conventional Ga-FIB-SEM system?

Choose the Amber X 2 when you need large-volume 3D tomography (up to 1 mm) or reduced ion implantation damage, thanks to its Xe+ plasma FIB. For ultra-high-resolution milling of small features, a Ga-FIB may be more suitable.

What detectors and analytical techniques are integrated into the Amber X 2?

The system supports EDS for elemental analysis, EBSD for crystallography, and ToF-SIMS for surface chemistry, all within the same chamber, enabling multi-modal characterization without sample transfer.

What are the site requirements for installing the Amber X 2?

The instrument requires a stable, vibration-isolated floor, low electromagnetic interference, and a high-purity xenon supply for the plasma FIB. Electrical power must meet voltage and grounding specifications to ensure stable operation.

What maintenance and consumables are required for the Amber X 2?

Regular maintenance includes column alignment, aperture cleaning, and detector calibration. Consumables such as apertures, gas filters, and possibly filaments should be stocked per the manufacturer's schedule. Specific intervals are detailed in the maintenance manual.