Shimadzu Xdimensus 300
Shimadzu Xdimensus 300 — Spectrometers.
The Shimadzu Xdimensus 300 is a dimensional X-ray CT system with a 225 kV, 135 W generator and flat-panel detector, configured for non-destructive internal and external metrology of resin and light-metal parts up to ø300 mm × 210 mm and 10 kg. It achieves a sphere-distance error of ±(3.8 + L/50) µm and probing error PS/PF = 5.0 µm, making it suited to first-article inspection and dimensional verification where internal features are inaccessible.
Full specifications
| Sphere distance measurement error (XDimensus 300; example 5.8 μm for L = 100 mm) mfr | (3.8 + L/50)* μm (XDimensus 300; example 5.8 μm for L = 100 mm) |
| Measurable sample diameter mfr | ø300 mm (XDimensus 300) |
| Measurable sample height mfr | H 210 mm (XDimensus 300) |
| Cabinet width mfr | 2,195 mm (XDimensus 300) |
| Cabinet depth mfr | 1,561 mm (XDimensus 300) |
| Cabinet height mfr | 1,971 mm (XDimensus 300) |
| Installation space width mfr | 4000 mm (XDimensus 300) |
| Installation space depth mfr | 3500 mm (XDimensus 300) |
| Max. tube voltage mfr | 225 kV (XDimensus 300) |
Description
Construction and positioning
- The system comprises a shielded CT cabinet (W 2,195 × D 1,561 × H 1,971 mm, approx. 4,000 kg), a separate air-conditioning unit (W 832 × D 961 × H 1,529 mm, approx. 200 kg), and a specialized control desk (W 1,200 × D 700 × H 1,270 mm, approx. 50 kg). - The X-ray generator is rated 135 W with a maximum tube voltage of 225 kV; the detector is a flat-panel type with 16-bit (65,536) gray levels. - Maximum CT scan region is ø300 mm × H 210 mm, and maximum sample size and weight are 300 mm and 10.0 kg, respectively. The target object class is resins and light metals. ### Measurement behavior
- CT data acquisition time ranges from 20 to 60 minutes, with a maximum CT image size of 2048 × 2048 pixels. - Dimensional performance is specified as sphere-distance error ±(3.8 + L/50) µm and probing error PS/PF = 5.0 µm, indicating that accuracy degrades with distance L according to the linear term. - No digitized curve points or mode-specific performance data are available; behavior under different media or load conditions is not characterized in the supplied facts. ### Installation and operation
- Power requirements are split: main unit single-phase AC 200 V ±10%, 4 kVA; air-conditioning unit three-phase AC 200 V ±10%, 2.6 kVA; control computer single-phase AC 100 V ±10%, 1.5 kVA. A Type-D ground with 100 Ω max resistance is required. - An air source of 0.6–1 MPa at 60 SLPM minimum is required. External leakage dose is 1 µSv/h max.
Integration & Operating Notes
The main unit requires single-phase 200 V (4 kVA), the air-conditioning unit requires three-phase 200 V (2.6 kVA), and the control computer requires single-phase 100 V (1.5 kVA). Each must be supplied from an appropriate branch circuit; sharing a feed or omitting the three-phase supply will prevent normal operation.
The maximum CT scan region is ø300 mm × H 210 mm, and the maximum sample size and weight are 300 mm and 10.0 kg. Exceeding these limits risks collision with the source-detector geometry or inaccurate reconstruction; fixturing must keep the sample within the scan envelope.
The system requires an air source delivering 0.6 MPa to 1 MPa at a minimum flow of 60 SLPM. This air is used by the air-conditioning unit and possibly for pneumatic functions; a stable, dry supply must be available at the installation site.
A dedicated Type-D ground with ground resistance not exceeding 100 Ω is specified. This is required for electrical safety and to minimize noise in the low-current detector electronics; the ground must be verified before commissioning.
Selection & Integration Q&A
Provide single-phase 200 V 4 kVA for the main unit, three-phase 200 V 2.6 kVA for the air-conditioning unit, and single-phase 100 V 1.5 kVA for the control computer, plus a Type-D ground (100 Ω max) and air at 0.6–1 MPa, 60 SLPM min.
The shield box weighs approx. 4,000 kg and the air-conditioning unit approx. 200 kg; the floor must support these loads. External leakage dose is 1 µSv/h max, so radiation shielding is integral to the cabinet and no additional enclosure is specified.