Waters ACQUITY Arc MDLC System
Waters ACQUITY Arc MDLC System — Chromatographs with Flow rate 5 milliliter/minute, Max pressure 65.5 megapascal.
The ACQUITY Arc MDLC System is a multi-dimensional liquid chromatography (MDLC) instrument with three fluidic paths (Path 1, Path 2, waste) enabling automated method development and complex sample analysis. It delivers flow rates up to 5.0 mL/min and pressures up to 9500 psi, with a total system bandspread of ≤30 µL and dwell volumes of ≤1450 µL (Path 1) and ≤1150 µL (Path 2). Designed for laboratory use, it operates in a 4–40 °C environment and supports column temperatures from 4 to 90 °C (CM-A) or 20 to 65 °C (30 cm CH).
Full specifications
| Flow rate | 5.0 mL/min |
| Max pressure | 9500 psi |
| Column temperature | 90.0 °C |
| Injection volume | 50.0 μL |
| Total system bandspread, 4s mfr | ≤30 μL (default configuration) |
| Dwell volume (total system) mfr | Path 1≤1450 μL; Path 2≤1150 μL |
| Gradient delay volume mfr | Path 1≤1050 μL; Path 2≤750 μL |
| Cycle time mfr | ≤30 seconds inject-to-inject |
| Number of fluidic paths mfr | Three (Path 1, Path 2, and waste) |
| Flow accuracy mfr | +/- 1.0% at 0.5, 3.0, and 5.0 mL/min |
| Flow precision mfr | ≤0.075% RSD or +/-0.020 min SD |
| Sample compartment temperature mfr | 4.0–40.0 °C |
| Column compartment temperature (CM-A) mfr | 4.0 to 90.0 °C |
| Column compartment temperature (30 cm CH) mfr | 20.0 (or 5.0 °C above ambient) to 65.0 °C |
| Operating temperature range mfr | 4.0 to 40.0 °C |
| Power requirements mfr | 100 to 240 VAC |
| Height | 571 mm |
| Weight | 59.1 kg |
| Width | 574 mm |
| Depth mfr | 62.8 cm (24.7 in.) |
| Power consumption | 50 W |
| Line frequency mfr | 50 to 60 Hz |
| pH range mfr | 1 to 12.5 |
| Operating humidity range mfr | 20% to 80%, non-condensing |
| Acoustic noise [total system] mfr | ≤65 dBA |
Description
Construction and Positioning
- The ACQUITY Arc MDLC System is a multi-path chromatograph with three fluidic paths: Path 1, Path 2, and waste. This configuration allows automated switching between two independent flow paths, facilitating multi-dimensional separations or method development without manual re-plumbing. - The system includes a sample compartment with temperature control (4.0–40.0 °C) and a column compartment (CM-A) capable of 4.0–90.0 °C, or a 30 cm CH column heater with a range of 20.0 (or 5.0 °C above ambient) to 65.0 °C. The total system bandspread is ≤30 µL in the default configuration, ensuring minimal dispersion for sharp peaks. - Physical dimensions: 571 mm height, 574 mm width, 62.8 cm depth, and 59.1 kg weight. Power consumption is 50 W, with a universal 100–240 VAC, 50–60 Hz supply. ### Behavior Under Load and in Different Modes
- The system supports flow rates up to 5.0 mL/min with flow accuracy of ±1.0% at 0.5, 3.0, and 5.0 mL/min, and flow precision of ≤0.075% RSD or ±0.020 min SD. Maximum operating pressure is 9500 psi (65.5 MPa), suitable for UHPLC and HPLC columns. - Dwell volume (total system) is ≤1450 µL for Path 1 and ≤1150 µL for Path 2; gradient delay volume is ≤1050 µL (Path 1) and ≤750 µL (Path 2). These low volumes enable rapid gradient methods and minimize delay effects. - Injection volume up to 50.0 µL and cycle time ≤30 seconds inject-to-inject support high-throughput analyses. The system operates with mobile phases in the pH range 1 to 12.5, accommodating a wide variety of buffers and solvents. ### Installation, Connection, and Control
- The system requires a 100–240 VAC, 50–60 Hz power source and consumes 50 W. It operates in ambient temperatures of 4.0 to 40.0 °C and humidity of 20% to 80%, non-condensing. Acoustic noise is ≤65 dBA. - Fluidic connections: three paths (Path 1, Path 2, waste) allow integration with detectors, fraction collectors, or mass spectrometers. The system is controlled via Waters Empower software (not detailed in provided facts).
Integration & Operating Notes
Operating above 9500 psi (65.5 MPa) may cause seal failure, tubing rupture, or column damage. The pressure limit applies to all fluidic paths and must be monitored via the system controller. Ensure method pressures are set with a safety margin, especially when using small-particle columns.
Using mobile phases outside the pH range of 1 to 12.5 can degrade seals, check valves, and column hardware. This range applies to the entire flow path; verify buffer compatibility and flush the system with neutral solvent after using extreme pH to prolong component life.
Operating outside the 4.0–40.0 °C ambient range may affect flow precision, detector baseline, and column thermostat performance. Ensure the laboratory HVAC maintains this range and avoid placing the system near heat sources or in direct sunlight.
Relative humidity above 80% or condensation can cause electrical shorts, corrosion, and optical fogging. Install the system in a controlled environment with humidity between 20% and 80%, non-condensing. Use dehumidifiers if necessary.
Selection & Integration Q&A
Choose the MDLC System when you need automated multi-dimensional separations or method development with two independent flow paths (Path 1 and Path 2). A single-path system is sufficient for routine single-method analyses and offers simpler plumbing and lower cost.
Yes, the system supports mobile phases from pH 1 to 12.5. This range is compatible with many buffers, but avoid extremes to prolong seal life. Flush with neutral solvent after use and monitor for increased pressure.
The base system includes the instrument only. You must separately order columns, tubing, fittings, solvent bottles, and consumables like seals and filters. A Waters Empower software license and a qualified computer are also required for control and data analysis.