Waters ACQUITY Premier System with Multi-Dimensional Technology
Waters ACQUITY Premier System with Multi-Dimensional Technology — Chromatographs with Flow rate 2 milliliter/minute, Max pressure 103.4 megapascal.
The ACQUITY Premier System with Multi-Dimensional Technology is a high-pressure liquid chromatograph configured for automated multi-dimensional separations, integrating binary or quaternary solvent delivery with a 15,000 psi-capable pump and dual column compartments. It supports flow rates from 0.001 to 2.000 mL/min and injection volumes from 0.1 to 10.0 µL as standard, with optional extension loops up to 1000 µL. The system is intended for method development and complex sample analysis requiring orthogonal separation dimensions within a single instrument footprint.
Full specifications
| Flow rate | 2.0 mL/min |
| Max pressure | 15000 psi |
| Column temperature | 90.0 °C |
| Injection volume | 10.0 μL |
| Number of solvents mfr | Up to four, in any combination of two: Al or A2 |
| Solvent conditioning mfr | Five vacuum degasser, one allocated for injector |
| Operating flow rate range mfr | 0.001 to 2.000 mL/min, in 0.001 mL increments (f |
| Maximum operating pressure mfr | 15,000 psi up to 1 mL/min, 9000 psi up to 2 mL/m |
| Injection volume range mfr | 0.1 to 10.0 μL as standard; Up to 1000.0 μL with |
| Sample compartment temp. mfr | 4.0 to 40.0 °C, settable in 0.1 °C increment |
| Column compartment(s) temperature range mfr | 4.0 to 90.0 °C, settable in 0.1 °C increments |
| Operating temperature range mfr | 4.0 to 40.0 °C (39.2 to 104.0 °F) |
| Height | 1034 mm |
| Width | 838 mm |
| Depth mfr | 86.4 cm (34 in.) |
| Voltage mfr | 100 to 240 VAC |
| Frequency mfr | 50 to 60 Hz |
| Operating humidity range mfr | 20% to 80%, non-condensing |
| Acoustic noise mfr | <62 dBA |
Description
Construction and Architecture
- The system combines a high-pressure pump, autosampler with temperature-controlled sample compartment (4.0–40.0 °C), and two independently temperature-controlled column compartments (4.0–90.0 °C) in a single chassis measuring 1034 mm (H) × 838 mm (W) × 864 mm (D). - Solvent delivery supports up to four solvents in any combination of two: A1 or A2 and B1 or B2, with five vacuum degassers—one dedicated to injector purge solvent. - The multi-dimensional configuration enables automated switching between two separation modes without manual intervention, distinguishing it from standard single-dimension ACQUITY systems. ### Behavior Under Load and in Different Modes
- Maximum operating pressure is 15,000 psi up to 1 mL/min and 9000 psi up to 2 mL/min per pump, with a total system limit of 15,000 psi. This pressure envelope supports sub-2 µm particle columns at analytical flow rates. - Flow rate is settable from 0.001 to 2.000 mL/min in 0.001 mL increments (firmware v1.71 and later), allowing precise control for narrow-bore and micro-bore applications. - Injection volume ranges from 0.1 to 10.0 µL as standard; optional extension loops extend the upper limit to 1000.0 µL for large-volume injections. - Column and sample compartments maintain set temperatures within 0.1 °C increments, ensuring retention-time reproducibility across runs. ### Installation, Connection, and Control
- The system operates on 100–240 VAC, 50–60 Hz, and produces acoustic noise below 62 dBA. - Operating environment must be maintained between 4.0 and 40.0 °C and 20% to 80% relative humidity, non-condensing.
Integration & Operating Notes
The pump's maximum pressure is 15,000 psi only up to 1 mL/min; between 1 and 2 mL/min the limit drops to 9000 psi per pump, and the combined system pressure must never exceed 15,000 psi. Exceeding these limits risks seal failure and invalid results.
Operation outside this range can affect detector baseline stability, column thermostat performance, and electronics reliability. Ensure laboratory HVAC maintains these conditions continuously, especially when the system is used unattended overnight.
Selection & Integration Q&A
Choose this model when your method requires automated orthogonal separations—e.g., heart-cutting or comprehensive 2D-LC—within one instrument. A standard single-dimension system suffices for routine assays without multi-dimensional capability, and it avoids the added complexity of dual-column switching.
Ambient must remain 4–40 °C and 20–80% RH non-condensing. The system is designed for continuous operation, but pump seals and degasser membranes are wear items; no duty-cycle restriction is stated, yet preventive maintenance should be planned based on solvent use and pressure history.