Waters ACQUITY UPLC M-Class System w/ 2D Technology
Waters ACQUITY UPLC M-Class System w/ 2D Technology — Chromatographs with Flow rate 2×10⁻⁷ milliliter/minute, Max pressure 103.4 megapascal.
The ACQUITY UPLC M-Class System with 2D Technology is a binary, non-ferrous flow-path chromatograph configured for two-dimensional separations at pressures up to 15,000 psi (1,034 bar). It accommodates a single column from 75 µm to 4.6 mm ID and up to 250 mm length, with injection volumes down to 0.1 µL and flow rates as low as 0.2 nL/min. It serves as the primary separation engine in micro- to narrow-bore UPLC workflows requiring orthogonal second-dimension analysis.
Full specifications
| Flow rate | 0.2 nL/min |
| Max pressure | 15000 psi |
| Injection volume | 0.1 µL |
| Sample flow path mfr | Non-ferrous |
| Sample compartment mfr | 4–40 ̊C |
| Pump options mfr | Binary |
| Column capacity mfr | Single column, 75 μm to 4.6 mm internal diameter |
| Maximum sample capacity mfr | Up to 21 plates (with Sample Organizer) |
| Detector options mfr | PDA Detector, TUV Detector, Mass Spectrometers |
| External control mfr | MassLynx Software |
| Height | 697 cm |
| Width | 343 cm |
| Depth mfr | 71.2 cm (28.0 in.) |
| pH range mfr | 2 to 10 |
Description
Construction and positioning
- Binary pump architecture with a non-ferrous sample flow path, suitable for biological and metal-sensitive analytes. - Single-column capacity spanning 75 µm to 4.6 mm ID and up to 250 mm length, covering micro-bore through analytical-scale separations. - Detector compatibility includes PDA, TUV, and mass spectrometers, with external control via MassLynx software. ### Behavior under load and in different modes
- Maximum operating pressure is 15,000 psi (1,034 bar), supporting sub-2 µm particle columns and long gradients at micro-flow rates. - Flow rate extends down to 0.2 nL/min, enabling capillary and nano-scale separations when paired with appropriate columns and injection volumes. - Injection volume as low as 0.1 µL supports trace-level and limited-sample applications. - pH range of 2 to 10 accommodates a broad set of mobile-phase chemistries; sample compartment is thermostatted from 4 to 40 °C. ### Installation, connection, and operation
- External control is exclusively through MassLynx software; no standalone control panel is described. - The system requires connection to a compatible detector (PDA, TUV, or MS) and, for 2D operation, a second dimension pump and valve configuration as part of the 2D Technology package. - Sample capacity can be expanded to up to 21 plates with the optional Sample Organizer, which is not part of the base delivery. - No digitized curve points or PDF digests were provided, so detailed installation and maintenance procedures cannot be summarized here.
Integration & Operating Notes
Operating above the rated maximum pressure risks seal failure, column damage, and invalid results. Ensure method gradients and column backpressure calculations stay below this limit, especially with sub-2 µm particles and high flow rates.
The non-ferrous flow path tolerates pH 2–10; outside this range, corrosion or analyte adsorption may occur. Verify buffer and sample pH before analysis, and flush the system after using extreme pH conditions.
The instrument has no standalone control interface; all methods, sequences, and 2D valve switching are managed through MassLynx. Ensure the controlling workstation is available and configured before startup, and that the software version supports the 2D Technology configuration.
Base delivery does not include the Sample Organizer required to reach the maximum sample capacity of 21 plates. Order it separately if high-throughput or long unattended sequences are needed, and account for its additional bench space and connections.
Selection & Integration Q&A
Choose 2D when your application requires orthogonal separation of complex mixtures that cannot be resolved in a single dimension. A standard M-Class system is sufficient for routine micro- to narrow-bore UPLC separations without a second dimension.
The system is compatible with PDA, TUV, or mass spectrometers and is controlled externally via MassLynx software. Ensure the detector and MassLynx version support the 2D Technology configuration and the intended flow rates.