Waters Alliance HPLC System
Waters Alliance HPLC System — Chromatographs with Flow rate 10 milliliter/minute, Max pressure 34.47 megapascal.
The Alliance HPLC System is a quaternary, low-pressure-gradient HPLC platform with vacuum degassing and Auto-Blend technology for up to four mobile phases. It delivers flow rates to 10 mL/min against 5000 psi (34.5 MPa) and supports injection volumes from 0.1 to 100 µL standard, with an optional 2 mL loop. It serves as the separation and delivery core in analytical HPLC workflows, compatible with a broad range of detectors and controlled via Empower or MassLynx software.
Full specifications
| Flow rate | 10 mL/min |
| Max pressure | 5000 psi |
| Column temperature | 4–40 °C |
| Injection volume | 100 μL |
| Mobile phases mfr | Up to 4 with Auto-Blend Technology |
| Sample carryover mfr | ≤0.0025% (Caffeine) under specified conditions |
| Sample compartment mfr | 4–40 °C |
| Pump options mfr | Quaternary |
| Solvent conditioning mfr | Vacuum Degas |
| Column capacity mfr | Standard up to 3 columns |
| Maximum sample capacity mfr | 120 |
| Detector options mfr | Tunable UV, Photo Diode Aray, Fluorescence, Char |
| External control mfr | Empower Software, MassLynx Software |
| Injection volume range mfr | 0.1 to 100 μL standard, up to 2 mL optional |
| Height | 571 cm |
| Width | 457 cm |
| Depth mfr | 57.1 cm (22.5 in.) or 64.8 cm (25.5 in.) with sa |
| Width with column heater mfr | 58.4 cm (23.0 in.) |
| Front panel display mfr | Easy to use control panel |
Description
Construction and positioning
- Integrated quaternary pump with vacuum degasser and Auto-Blend proportioning valve for up to four solvents. - Standard column capacity: up to three columns; column heater widens the footprint to 58.4 cm. - Sample compartment temperature control from 4 to 40 °C; sample capacity up to 120 vials. - Detector-agnostic design: supports tunable UV, PDA, fluorescence, charged aerosol, refractive index, evaporative light scattering, electrochemical, conductivity, and mass spectrometry detectors. ### Behavior under load and in different modes
- Flow rate up to 10 mL/min at pressures up to 5000 psi (34.5 MPa); suitable for standard-bore and some narrow-bore columns. - Injection volume range 0.1–100 µL standard; optional 2 mL loop for larger-volume injections. - Sample carryover ≤0.0025% (caffeine) under specified conditions, minimizing cross-contamination in high-throughput sequences. - Quaternary low-pressure gradient formation via Auto-Blend; vacuum degassing protects against bubble formation at elevated flow rates. ### Installation, connection, and control
- External control via Empower or MassLynx software; front panel provides local control. - Detector and column heater modules integrate into the system stack; ensure sufficient bench space for the chosen configuration (depth 57.1 cm or 64.8 cm with sample heater/cooler).
Integration & Operating Notes
Operating above 5000 psi (34.5 MPa) risks seal damage, column failure, and invalid results. The pump and plumbing are rated for this maximum; ensure method pressures remain below this limit, especially with small-particle columns or high flow rates.
The column heater/cooler maintains 4–40 °C. Exceeding this range may cause inaccurate temperature control, affecting retention times and separation. Verify that the setpoint and ambient conditions allow the module to hold the required temperature.
Empower or MassLynx software is required for automated sample injection, gradient programming, and data acquisition. The front panel supports manual control but not full automation. Ensure the control software is installed and licensed before attempting automated runs.
The system depth is 57.1 cm (22.5 in.) without the sample heater/cooler and 64.8 cm (25.5 in.) with it. Ensure the bench or stack accommodates the deeper configuration and allows adequate ventilation and access for service.
Selection & Integration Q&A
Choose the Alliance when method development or multi-solvent applications require quaternary low-pressure gradients with up to four mobile phases and Auto-Blend. For routine isocratic assays, a simpler binary or isocratic pump may suffice and reduce complexity.
The Alliance supports a wide range of detectors including UV, PDA, fluorescence, CAD, RI, ELSD, electrochemical, conductivity, and MS. Ensure your chosen detector is compatible with the system's flow path and that Empower or MassLynx software is available for control and data handling.
The base system typically includes the pump, autosampler, column heater, and necessary tubing, but detectors, columns, and software licenses are usually ordered separately. Consumables such as pump seals, degasser membranes, and sample vials are not included and should be stocked per the maintenance schedule.