Waters Fraction Manager - Analytical
Waters Fraction Manager - Analytical — Chromatographs with Flow rate 2.2 milliliter/minute, Max pressure 2.07 megapascal.
The Fraction Manager - Analytical is a benchtop fraction collector for analytical HPLC, with a 13.6 µL internal delay volume and a 0.1–5.0 mL/min flow range. It operates at up to 300 psi and maintains the fraction compartment from 4.0 to 40.0 °C, settable in 0.1 °C increments. It is used to collect precise fractions from analytical-scale separations under controlled temperature.
Full specifications
| Flow rate | 2.2 mL/min |
| Max pressure | 300 psi |
| Column temperature | 40.0 °C |
| Operating HPLC flow range mfr | 0.1 to 5.0 mL/min with high flow needle |
| pH operating range mfr | pH 2–12 |
| Internal delay volume mfr | 13.6 μL* |
| Needle move time mfr | 0.7 s Vessel to vessel with needle above vessel; |
| Carryover mfr | <0.15% with rinse enabled |
| Fraction compartment temperature mfr | Range 4.0–40.0 °C, settable in 0.1 °C increments |
| Integrated leak management mfr | Leak sensor as standard, and safe leak handling |
| Operating temperature mfr | Range 4–40 °C |
| Storage temperature mfr | -40 °C–60 °C |
| External control mfr | Empower® or MassLynx® Software with FractionLynx |
| External communications mfr | Ethernet interfacing via RJ45 connection to host |
| Event inputs/outputs mfr | Inject start, auxiliary output |
| Height | 27 cm |
| Weight | 20 kg |
| Width | 34 cm |
| Depth mfr | 71 cm (28 inches) |
| Voltage mfr | 90 to 264 VAC |
| Frequency mfr | 47 to 63 Hz |
| Primary wetted material mfr | MP35N, PEEK, Teflon, DLC, and Tefzel |
| Audible noise mfr | <60 db |
| Humidity mfr | 20% to 80% non-condensing |
Description
Construction and positioning
- Benchtop unit measuring 34 cm wide, 27 cm high, and 71 cm deep, weighing 20 kg. - Wetted flow path materials: MP35N, PEEK, Teflon, DLC, and Tefzel. - Integrated leak sensor as standard, with safe leak handling. ### Behavior under load and in different media
- Operating HPLC flow range: 0.1 to 5.0 mL/min with high-flow needle. - Maximum pressure: 300 psi (2.07 bar). - pH operating range: 2–12. - Internal delay volume: 13.6 µL. - Needle move time: 0.7 s vessel-to-vessel with needle above vessel; 1.1 s vessel-to-vessel with needle into bottom of vessel. - Carryover: <0.15% with rinse enabled. - Fraction compartment temperature: 4.0–40.0 °C, settable in 0.1 °C increments; maintains 19.0 °C below ambient with a tolerance range between -2.0 °C and 4.0 °C. ### Installation, connection, and control
- External control via Empower or MassLynx software with FractionLynx Application Manager. - Ethernet interfacing via RJ45 connection to host PC. - Event inputs/outputs: inject start, auxiliary output. - Voltage: 90 to 264 VAC; frequency: 47 to 63 Hz. - Operating temperature: 4–40 °C; humidity: 20% to 80% non-condensing; storage temperature: -40 °C to 60 °C. - Audible noise: <60 dB.
Integration & Operating Notes
The fraction manager is rated for a maximum pressure of 300 psi (2.07 bar). Exceeding this limit may damage the internal flow path or cause leaks. Ensure the HPLC system upstream does not generate pressures above this value at the fraction manager inlet.
The wetted materials (MP35N, PEEK, Teflon, DLC, Tefzel) are compatible with pH 2–12. Operating outside this range can cause corrosion or degradation, leading to leaks or sample contamination.
The power supply operates from 90 to 264 VAC at 47 to 63 Hz, so no voltage selection is required. Ensure the protective earth connection is reliable and that the supply can deliver the required current.
The event input for inject start must be wired to the autosampler or system controller to trigger fraction collection at the correct time. Without this signal, fractions may be offset, reducing recovery.
Carryover is specified as <0.15% only when the rinse function is enabled. Ensure the rinse solvent is appropriate for the application and that the rinse cycle is included in the method.
The fraction compartment can maintain 19.0 °C below ambient, but the ambient must be within 4–40 °C and humidity 20–80% non-condensing. Avoid direct sunlight and drafts to ensure temperature stability.
Selection & Integration Q&A
Choose this model for analytical HPLC flows of 0.1–5.0 mL/min and pressures up to 300 psi. For higher flow rates or pressures, a preparative-scale collector is required.
It requires an Ethernet connection to a host PC running Empower or MassLynx with FractionLynx, and an inject start signal from the autosampler. The flow path must not exceed 300 psi or pH 2–12.
Operate between 4 and 40 °C and 20–80% non-condensing humidity. The fraction compartment can be set from 4.0 to 40.0 °C but can only cool to 19.0 °C below ambient.
Dimensional Drawings & Technical Documentation
Dimensional drawings
Click drawing to inspect vector dimensions