Waters LC Prep 150 System for Sample Purification
Waters LC Prep 150 System for Sample Purification — Chromatographs with Flow rate 150 milliliter/minute, Max pressure 34.5 megapascal.
The Waters LC Prep 150 System is a preparative HPLC platform configured for sample purification, featuring a 150 mL/min pump, 345 bar (5000 psi) maximum operating pressure, and a 10 mL sample loop. It supports columns from 10 to 50 mm I.D. and offers up to four solvents with 11 gradient curves, distinguishing it as a dedicated purification instrument within the Waters preparative series. Its primary purpose is to deliver reproducible, scalable separations for milligram-to-gram scale purification in pharmaceutical and biochemical workflows.
Full specifications
| Flow rate | 150 mL/min |
| Max pressure | 345 bar |
| Injection volume | 10000 μL |
| Operating pressure range mfr | 5000 psi (345 bar) |
| Supported column dimensions mfr | 10, 19, 30, and 50 mm I.D. |
| Software mfr | ChromScope |
| Dwell volume mfr | ≤350 μL; <6.5 mL |
| Flow accuracy mfr | ±1.0% of required flow or 10 μL/min, whichever i |
| Composition accuracy mfr | ±1.0% of required flow or 5% to 95%, and from 1 |
| Composition precision mfr | Retention time variation <0.3% RSD or 0.1 min SD |
| Number of solvents mfr | Up to four: A1 or A2, B1 or B2 |
| Gradient composition curves mfr | Eleven (11) gradient curves including linear (1) |
| Compressibility compensation mfr | Automatic and continuous |
| Pump seal wash mfr | Integral, active, programmable |
| Priming mfr | Self-prime from solvent container on floor with |
| Collection capacity mfr | Standard test tube 12.0-18.0 O.D. rack Max. 162; |
| Injector mfr | 3725i continuous flow design (MBB) |
| Injectors mfr | 7725i analytical continuous flow design (MMB); 3 |
| Sample loop volume mfr | 10 mL sample loop |
| Sample capacity mfr | Two 12-vial trays for 10 mL vials |
| Syringe size mfr | 2.5 mL |
| Height | 64 cm |
| Weight | 60 kg |
| Width | 71 cm |
| Voltage mfr | 100 to 240 VAC |
| Wetted material mfr | 316 stainless steel, UHMWPE, sapphire, ruby, Tef |
Description
Construction and Positioning
- The LC Prep 150 is a benchtop preparative HPLC system with a 316 stainless steel, PEEK, and Tefzel flow path, designed for solvent compatibility and corrosion resistance. - It is equipped with a 3725i continuous flow injector (MBB) and a 10 mL sample loop, enabling large-volume injections up to 10,000 µL. - The system supports column inner diameters of 10, 19, 30, and 50 mm, making it adaptable to method development and scale-up. - Compared to analytical siblings, this modification prioritizes flow rate (150 mL/min) and pressure (345 bar) over high-resolution analytical performance, targeting purification rather than analysis. ### Behavior Under Load and in Different Media
- The pump delivers flow rates up to 150 mL/min with ±1.0% accuracy, and composition accuracy of ±1.0% across 5–95% and 1–150 mL, ensuring reproducible gradients. - Automatic and continuous compressibility compensation maintains stable flow under varying backpressures up to 345 bar. - Eleven gradient curves (linear, step, concave, convex) allow precise control of elution profiles for different sample types. - The integral, active, programmable pump seal wash extends seal life when using aggressive solvents or high-salt buffers. ### Installation, Connection, and Operation
- The system operates on 100–240 VAC and requires a benchtop footprint of 71 cm width and 64 cm height, weighing 60 kg. - It includes a 2.5 mL syringe for manual injections and supports two 12-vial trays for 10 mL vials, with optional racks for test tubes, scintillation vials, microtiter plates, and prep funnels. - Control is via ChromScope software, which manages gradient composition, injection sequences, and fraction collection. - Self-priming from solvent containers on the floor with dry lines simplifies setup and reduces downtime.
Integration & Operating Notes
Operating above the maximum pressure rating can damage pump seals, column hardware, and tubing. The pressure limit applies to the entire flow path, including the injector and column. Ensure the column and connections are rated for at least 345 bar, and monitor pressure during method development to avoid overpressure trips.
The integral pump seal wash is programmable and active, but it requires periodic replenishment of wash solvent and verification of flow. Neglecting the seal wash can lead to premature seal wear, especially when using buffers or aggressive solvents. Follow the recommended maintenance schedule in the user manual.
Selection & Integration Q&A
Choose the LC Prep 150 when you need flow rates up to 150 mL/min and pressures up to 345 bar for milligram-to-gram purification. Its 10–50 mm column compatibility and 10 mL injection volume suit scale-up from analytical methods. For lower flow rates or higher resolution, consider analytical siblings.
The system integrates with fraction collectors via ChromScope software, which controls collection based on time or peak detection. Ensure the collector supports the flow rates and volumes used. Detector connections require analog or digital I/O compatible with the system's communication ports.
The base system includes the pump, injector, and software, but consumables such as columns, solvent filters, and sample loops are not included. Fraction collection racks for test tubes, scintillation vials, and microtiter plates are optional. Regular maintenance kits for pump seals and check valves are available separately.