Waters Programmable Heater-Shaker+ Device
Waters Programmable Heater-Shaker+ Device — Laboratory automation & equipment.
The Waters Programmable Heater-Shaker+ Device is a connected laboratory shaker with a shaking speed range of 200–2,500 rpm and temperature control from ambient to 99°C in 1.0°C steps. It accepts ø36.5 mm bottles and achieves 0.1 mm zero-positioning accuracy, distinguishing it within the Heater-Shaker+ line by its programmable, network-ready design. It is intended for automated sample preparation and incubation workflows integrated via Wi-Fi or Ethernet with OneLab software and Andrew+, Pipette+, or manual systems.
Full specifications
| Shaking speed mfr | 200 to 2,500 rpm |
| Temperature range mfr | ambient up to 99°C |
| Temperature steps mfr | 1.0 °C |
| Zero-positioning accuracy mfr | 0.1 mm |
| Bottle compatibility mfr | ø36.5 mm bottles |
| Connectivity mfr | Wi-Fi or Ethernet |
| Software Compatibility mfr | OneLab |
| System Compatibility mfr | Andrew+, Pipette+, Manual |
| UNSPSC mfr | 41104018 |
| Brand mfr | Heater-Shaker+ |
| Product Type mfr | Connected Device |
| Mixing orbit constant mfr | 2 mm |
| Speed setting resolution mfr | 1 rpm |
| Mixing regulation accuracy mfr | ±25 rpm |
| Ingress protection mfr | IP20 |
| Dimensions (W x L x H) mfr | 170 x 162 x 100 mm (The specified dimensions are subject to change according to) |
| Weight | 2.55 kg |
| Power consumption | 120 W |
| Mixing frequency mfr | 200 rpm up to 2500 rpm rpm (The maximum speed may differ according to the type of used l) |
| External power supply Input mfr | 100-240 VAC |
| External power supply Input current mfr | 1.4 A |
| External power supply Output voltage mfr | 24 VDC |
| External power supply Output current mfr | 5 A |
| Power or current rating mfr | 5 A |
| Operating voltage mfr | 24 VDC |
| Overvoltage category DC port mfr | Cat I |
| Relative humidity mfr | 80 % (at 37°C) |
| Maximum operating altitude mfr | 2000 m |
| Pollution degree of the intended environment mfr | Pollution degree 2 |
| Warranty mfr | 1 year |
Description
Construction and positioning
- The Programmable Heater-Shaker+ is a connected device in the Heater-Shaker+ series, designed for integration into automated laboratory workflows. - It supports ø36.5 mm bottles and provides programmable shaking and heating, with 0.1 mm zero-positioning accuracy for precise sample handling. - Unlike basic shakers, it offers Wi-Fi or Ethernet connectivity and OneLab software compatibility, enabling remote control and monitoring. ### Behavior under load and in different modes
- Shaking speed is adjustable from 200 to 2,500 rpm, allowing gentle mixing to vigorous agitation. - Temperature can be set from ambient up to 99°C in 1.0°C increments, suitable for incubation and heat-shaking protocols. - The device is compatible with Andrew+, Pipette+, and manual operation, providing flexibility in automation level. ### Installation, connection, and operation
- The unit connects via Wi-Fi or Ethernet to a network for integration with OneLab software, enabling protocol programming and data logging. - It is a connected device that can be part of a larger automated system, requiring proper network configuration and power supply.
Integration & Operating Notes
The device should be placed on a stable, level bench to prevent vibration and ensure proper operation, especially at higher speeds. Adequate clearance around the unit is necessary for ventilation and access.
The Heater-Shaker+ operates on standard laboratory power; ensure the supply matches the device's voltage and current requirements. Use a grounded outlet to prevent electrical hazards.
To enable remote programming and monitoring via OneLab, the device must be configured with a static IP or DHCP reservation and connected to the same network as the control software. Firewall settings may need adjustment to allow communication.
Clean the device regularly to prevent sample residue buildup. Periodically verify temperature and shaking speed accuracy using calibrated instruments. Refer to the manual for maintenance intervals.
Selection & Integration Q&A
Choose this model when you need programmable control, network connectivity (Wi-Fi/Ethernet), and integration with OneLab software for automated workflows. For simpler, manual-only shaking, consider non-programmable variants.
The device must be connected via Wi-Fi or Ethernet to the same network as the robot controller. Ensure compatibility with Andrew+ or Pipette+ systems and configure OneLab software to coordinate actions. A stable network and proper IP addressing are essential.
Regular cleaning and periodic calibration are recommended. Accessories such as bottle clamps for ø36.5 mm bottles and network cables are not included and must be ordered separately. Refer to the manual for detailed maintenance schedules.