Waters SFC Prep 350 System

Waters SFC Prep 350 System — Chromatographs with Flow rate 350 milliliter/minute, Max pressure 32 megapascal.

The Waters SFC Prep 350 System is a preparative supercritical fluid chromatography (SFC) instrument configured with a P-350 CO2 pump (35–350 mL/min) and a P-200X co-solvent pump (20–200 mL/min), operating up to 320 bar. It is distinguished within the series by its high flow rate and 2 mL standard injection loop, enabling milligram-to-gram scale purifications. The system is used for fraction collection in pharmaceutical and natural product purification processes.

Flow rate
350 milliliter/minute
Max pressure
32 megapascal

Full specifications

Core Performance & Functional Specifications
Flow rate 350 mL/min
Max pressure 320 bar
Column temperature 25 °C
Injection volume 2 mL
Co-solvent percentage range mfr 5% to 55%
Recommended column size mfr 3 and 5 cm I.D.
Fraction capacity mfr 5+1
Flow rate range for CO2 pump (P-350) mfr 35 to 350 mL/min
Flow rate range for co-solvent pump (P-200X) mfr 20 to 200 mL/min
Wavelength range mfr 190 to 700 nm
UV lamp mfr Deuterium
Visible lamp mfr Tungsten/halogen
Flow cell mfr Preparative standard
Pathlength mfr Preparative 0.5 mm
Separators mfr Six 1 L separators for collecting five fractions
Dimensions, Weight & Mechanical Design
Height 135 cm
Weight 195 kg
Width 107 cm
Maximum pressure (Mass Flow Meter) mfr 100 bar (1450 psi)
Electrical, Power & Drive Specifications
Voltage mfr 110 to 220 VAC
Frequency mfr 50 to 60 Hz
Materials, Media & Process Compatibility
Liquid CO2 inlet pressure mfr 55 to 100 bar (797 to 1450 psi)
Liquid CO2 inlet temperature mfr 5 to 25 °C
Cell material of construction mfr Sapphire PEEK, 316 stainless-steel
Operating Conditions, Environment & Protection
Cooling of CO2 pump mfr Circulating coolant

Description

Construction and positioning

The SFC Prep 350 System is a preparative-scale SFC instrument built around a P-350 CO2 pump and a P-200X co-solvent pump, with a maximum pressure rating of 320 bar. It is positioned as the highest-flow model in the series, delivering up to 350 mL/min of CO2, compared to lower-flow siblings. The system includes a preparative UV detector with a 0.5 mm pathlength, 2.0 µL flow cell, and a fraction collection module with six 1 L separators (five fractions plus one waste). ### Behavior under load and media

Integration & Operating Notes

Process Limits
CO2 inlet pressure must stay within 55–100 bar

Operating the CO2 pump outside the specified inlet pressure range (55–100 bar) can cause cavitation or pump damage. Ensure the CO2 supply is regulated to maintain liquid phase and is cooled to 5–25 °C before entering the pump.

Factory Specification Sheet
Cooling & Media
CO2 pump requires circulating coolant for stable operation

The CO2 pump is cooled by a circulating coolant to prevent vapor lock and maintain consistent flow. The coolant supply must be connected and maintained at a temperature that keeps the pump head below the CO2 vaporization point under all operating pressures.

Factory Specification Sheet
Maintenance
Regular replacement of pump seals and check valves is required

The CO2 and co-solvent pumps contain wear parts (seals, check valves) that must be replaced at intervals specified in the service manual to prevent leaks and flow inconsistencies. Use only Waters-approved spare parts to maintain performance and safety.

Instruction Manual, Section 6 Maintenance

Selection & Integration Q&A

When should I choose the SFC Prep 350 System over other models in the series?

Choose the 350 when your purification requires flow rates up to 350 mL/min and pressures up to 320 bar, typical for gram-scale separations. Lower-flow models are better for analytical or small-scale prep where sample mass is limited.

What are the requirements for the CO2 supply and cooling when integrating this system?

The CO2 must be supplied as a liquid at 55–100 bar and 5–25 °C, and the pump requires a circulating coolant to maintain temperature. Ensure proper pressure regulation and cooling to avoid pump cavitation and inconsistent flow.