Waters Waters Fraction Collector IV
Waters Waters Fraction Collector IV — Laboratory automation & equipment.
The Waters Fraction Collector IV is a benchtop fraction collector with a 0.5–300 mL/min flow range and a 300 mm width, designed for laboratory automation. It accommodates up to 162 test tubes (12–18 mm O.D.), 162 scintillation vials (17 mm O.D.), 60 scintillation vials (30 mm O.D.), or six 96-well microtiter plates, with a 0.2 s nozzle travel time between adjacent tubes. Ethernet communication and a 100–240 V AC input enable integration into automated purification and analysis workflows.
Full specifications
| Flow rate range mfr | 0.5 mL/min to 300 mL/min |
| Scintillation vial (17 mm O.D.) mfr | Max. 162 |
| Scintillation vial (30 mm O.D.) mfr | Max. 60 |
| Microtiter plate mfr | 6×96 well plate |
| Preparative funnel mfr | 6×32-position rack |
| Microcentrifuge tube rack mfr | Up to three racks, 162 positions |
| Waters 3767 rack mfr | Max. 1 |
| Nozzle travel time mfr | 0.2 s (adjacent test tube movement time) |
| Electrical characteristics mfr | AC 100 V – 240 V, 50 Hz/60 Hz |
| Communication mfr | Ethernet communication |
| External dimensions mfr | Width: 300 mm, Depth: 600 mm, Height: 544 mm |
| Temp. range mfr | 4 to 40°C (39 to 104°F) |
| Weight | 14.1 kg |
| Standard test tube rack mfr | 12.0-18.0 mm O.D. rack, max. 162 |
Description
Construction and positioning
- Benchtop unit with external dimensions 300 mm (W) × 600 mm (D) × 544 mm (H) and weight 14.1 kg. - Accepts multiple rack types: standard test tube rack (12.0–18.0 mm O.D., max. 162 positions), scintillation vial racks (17 mm O.D., max. 162; 30 mm O.D., max. 60), microtiter plate (6×96 well), preparative funnel (6×32-position rack), microcentrifuge tube rack (up to three racks, 162 positions), and Waters 3767 rack (max. 1). ### Behavior under load and in different modes
- Flow rate range: 0.5 mL/min to 300 mL/min. - Nozzle travel time: 0.2 s for adjacent test tube movement, enabling rapid fraction collection. - No digitized curve points or additional performance data are provided; operation is limited to the specified flow range and rack configurations. ### Installation, connection, and operation
- Electrical: AC 100–240 V, 50/60 Hz. - Communication: Ethernet. - Operating temperature range: 4 to 40°C (39 to 104°F).
Integration & Operating Notes
The unit accepts 100–240 V AC at 50 or 60 Hz, allowing direct connection to standard laboratory mains without a step-down transformer. Ensure the supply circuit can handle the instrument's current draw (not specified) and is properly grounded.
Operating below 0.5 mL/min or above 300 mL/min may result in inaccurate fraction collection or instrument malfunction. Verify that the pump or upstream flow is calibrated to remain within this range during collection.
Selection & Integration Q&A
The collector requires a pump capable of delivering 0.5–300 mL/min and an Ethernet connection for control. Ensure the pump output is compatible with the collection vessel format and that the control software supports Ethernet communication.