Technical Data Sheet — 2BH1900 IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH1 900: side channel blowers with IE3 motors, sizes 1-4, 3~ 50/60 Hz, IP55, insulation class F, UL/CSA approved; variants by voltage range and connection (Δ/Y) with order codes 2BH1900-1AK.., -1AQ..

Technical Data

Parameter Value Condition
Rated voltage 190-210 V p.2 ↗ 2BH1900-1AK01, size 1, 50 Hz, Δ
Rated current 30,8 A p.2 ↗ 2BH1900-1AK01, size 1, 50 Hz, Δ
Power consumption at pump shaft 8,6 kW p.2 ↗ 2BH1900-1AK01, size 1, 50 Hz
Max vacuum -190 mbar p.2 ↗ 2BH1900-1AK01, size 1, 50 Hz
Max pressure 180 mbar p.2 ↗ 2BH1900-1AK01, size 1, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1900-1AK01, size 1, 50 Hz
Weight 183 kg p.2 ↗ 2BH1900-1AK01, size 1
Rated voltage 190-210 / 380-420 V p.2 ↗ 2BH1900-1AK01, size 1, 60 Hz, Δ/Y
Rated current 35,2 / 17,6 A p.2 ↗ 2BH1900-1AK01, size 1, 60 Hz, Δ/Y
Power consumption at pump shaft 9,9 kW p.2 ↗ 2BH1900-1AK01, size 1, 60 Hz
Max vacuum -150 mbar p.2 ↗ 2BH1900-1AK01, size 1, 60 Hz
Max pressure 140 mbar p.2 ↗ 2BH1900-1AK01, size 1, 60 Hz
Sound pressure level 75 dB(A) p.2 ↗ 2BH1900-1AK01, size 1, 60 Hz
Rated voltage 220-240 / 380-420 V p.2 ↗ 2BH1900-1AK06, size 1, 50 Hz, Δ/Y
Rated current 26,8 / 15,5 A p.2 ↗ 2BH1900-1AK06, size 1, 50 Hz, Δ/Y
Power consumption at pump shaft 8,6 kW p.2 ↗ 2BH1900-1AK06, size 1, 50 Hz
Max vacuum -190 mbar p.2 ↗ 2BH1900-1AK06, size 1, 50 Hz
Max pressure 180 mbar p.2 ↗ 2BH1900-1AK06, size 1, 50 Hz
Sound pressure level 71 dB(A) p.2 ↗ 2BH1900-1AK06, size 1, 50 Hz
Weight 183 kg p.2 ↗ 2BH1900-1AK06, size 1
Rated voltage 475-525 V p.2 ↗ 2BH1900-1AQ03, size 1, 50 Hz, Y
Rated current 12,4 A p.2 ↗ 2BH1900-1AQ03, size 1, 50 Hz, Y
Power consumption at pump shaft 8,6 kW p.2 ↗ 2BH1900-1AQ03, size 1, 50 Hz
Max vacuum -190 mbar p.2 ↗ 2BH1900-1AQ03, size 1, 50 Hz
Max pressure 180 mbar p.2 ↗ 2BH1900-1AQ03, size 1, 50 Hz

Operating Limits

  • Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 15 °C p.1 ↗
  • Reference atmospheric pressure for performance curves: 1013 mbar p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH190 Series 2BH1, size 900
8-9 p.2 ↗ 1A Motor variant group (AK/AQ voltage range family)
field 3 p.2 ↗ □ Mains frequency / voltage option: 50 Hz or 60 Hz
field 4 p.2 ↗ □ Voltage code: K = 475-525 V Y (50 Hz) / 550-600 V Y (60 Hz); Q = 475-525 V Δ (50 Hz) / 550-600 V Δ (60 Hz); 5 = 400 V Δ / 690 V Y (50 Hz) / 460 V Δ (60 Hz); 7 = 400 V Δ / 690 V Y (50 Hz) / 460 V Δ (60 Hz)

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH1900-1AK01 p.2 ↗ 2BH1900-1AK01 size 1, 50/60 Hz, 190-210 V Δ / 380-420 V Y IE3
2BH1900-1AK11 p.2 ↗ 2BH1900-1AK11 size 2, 50/60 Hz, 190-210 V Δ / 380-420 V Y IE3
2BH1900-1AK21 p.2 ↗ 2BH1900-1AK21 size 3, 50/60 Hz, 190-210 V Δ / 380-420 V Y IE3
2BH1900-1AK31 p.2 ↗ 2BH1900-1AK31 size 4, 50/60 Hz, 190-210 V Δ / 380-420 V Y IE3
2BH1900-1AK06 p.2 ↗ 2BH1900-1AK06 size 1, 50/60 Hz, 220-240 V Δ / 380-420 V Y IE3
2BH1900-1AK16 p.2 ↗ 2BH1900-1AK16 size 2, 50/60 Hz, 220-240 V Δ / 380-420 V Y IE3
2BH1900-1AK26 p.2 ↗ 2BH1900-1AK26 size 3, 50/60 Hz, 220-240 V Δ / 380-420 V Y IE3
2BH1900-1AK36 p.2 ↗ 2BH1900-1AK36 size 4, 50/60 Hz, 220-240 V Δ / 380-420 V Y IE3
2BH1900-1AQ03 p.2 ↗ 2BH1900-1AQ03 size 1, 50/60 Hz, 475-525 V Y / 550-600 V Y IE3
2BH1900-1AQ07 p.2 ↗ 2BH1900-1AQ07 size 1, 50/60 Hz, 380-420 V Δ / 660-725 V Y IE3