Technical Data Sheet — G-BH7 2BH7420 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH7 420: side channel blower with integrated frequency converter (G-BH7 e series). Covers 2BH7420 variants at 100 Hz (400 V) and 87 Hz (380 V), plus 50 Hz operation via frequency converter (2BH7420-0AK26-1, -0AK36-1, -0AK66-1) and matching frequency converters 2FC4xxx-1□□00.

Technical Data

Parameter Value Condition
Rated frequency 100 Hz p.2 ↗ 2BH7420-0A321-1
Rated voltage 400 V p.2 ↗ 2BH7420-0A321-1
Rated motor current 6,5 A p.2 ↗ 2BH7420-0A321-1
Rated motor power 3,5 kW p.2 ↗ 2BH7420-0A321-1
Max. differential pressure (vacuum) -270 mbar p.2 ↗ 2BH7420-0A321-1
Max. differential pressure (pressure) 200 mbar p.2 ↗ 2BH7420-0A321-1
Sound pressure level 77 dB(A) p.2 ↗ 2BH7420-0A321-1
Weight 45 kg p.2 ↗ 2BH7420-0A321-1
Rated frequency 100 Hz p.2 ↗ 2BH7420-0A331-1
Rated voltage 400 V p.2 ↗ 2BH7420-0A331-1
Rated motor current 9,5 A p.2 ↗ 2BH7420-0A331-1
Rated motor power 5,0 kW p.2 ↗ 2BH7420-0A331-1
Max. differential pressure (vacuum) -550 mbar p.2 ↗ 2BH7420-0A331-1
Max. differential pressure (pressure) 450 mbar p.2 ↗ 2BH7420-0A331-1
Sound pressure level 77 dB(A) p.2 ↗ 2BH7420-0A331-1
Weight 50 kg p.2 ↗ 2BH7420-0A331-1
Rated frequency 100 Hz p.2 ↗ 2BH7420-0A361-1
Rated voltage 400 V p.2 ↗ 2BH7420-0A361-1
Rated motor current 12,7 A p.2 ↗ 2BH7420-0A361-1
Rated motor power 6,9 kW p.2 ↗ 2BH7420-0A361-1
Max. differential pressure (vacuum) -580 mbar p.2 ↗ 2BH7420-0A361-1
Max. differential pressure (pressure) 800 mbar p.2 ↗ 2BH7420-0A361-1
Sound pressure level 80 dB(A) p.2 ↗ 2BH7420-0A361-1
Weight 57 kg p.2 ↗ 2BH7420-0A361-1

Operating Limits

  • Suction and ambient temperature for stated total pressure differences: up to 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH7420 Blower type/size designation
8-9 p.2 ↗ 0A Series/variant field
converter field p.2 ↗ 2FC4xxx-1□□00 Frequency converter model; □□ = power class code (A–K)
converter suffix p.2 ↗ Z = U53 Option: PN 2 AIN / 2 AOUT / 4 DIGIN / 1 DIGOUT / 2 RELAYS / SERCOS3 interface, delivered installed

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH7420-0A321-1 p.2 ↗ 2BH7420-0A321-1 C 100 Hz, 400 V 3.5 kW, 45 kg
2BH7420-0A331-1 p.2 ↗ 2BH7420-0A331-1 D 100 Hz, 400 V 5.0 kW, 50 kg
2BH7420-0A361-1 p.2 ↗ 2BH7420-0A361-1 E 100 Hz, 400 V 6.9 kW, 57 kg
2BH7420-0AK26-1 p.2 ↗ 2BH7420-0AK26-1 C 50 Hz via frequency converter 3.5 kW, 40 kg
2BH7420-0AK36-1 p.2 ↗ 2BH7420-0AK36-1 D 50 Hz via frequency converter 5.0 kW, 45 kg
2BH7420-0AK66-1 p.2 ↗ 2BH7420-0AK66-1 E 50 Hz via frequency converter 6.9 kW, 49 kg