Operating Instructions — VLR 1000 HV central vacuum unit (BA 1880-EN, ed. 1.1 14.06.2021, EN)
Technical Reference Summary
Covered Models & Document Scope
This document (BA 1880-EN, Edition 1.1, 14.06.2021) covers the C-VLR 1000 HV+ central vacuum unit, a claw vacuum pump C-VLR 1000 VSD with control circuit for setpoint pressure. It applies to the VLR 1000 HV+ central vacuum unit and references the VLR 1000 vacuum pump, frequency converter, solenoid valve, and control unit. The XD variant (increased water vapour compatibility) is mentioned in the abbreviations and intended use, but no separate ordering codes or options are detailed.
Section-by-Section Technical Breakdown
This section describes the central vacuum unit components, control unit, control box, fields of application, and data plates. It includes the product overview figure, component list, data plate details, and application limits.
- Components include vacuum connection, exhaust air connection, cooling air inlet/outlet, oil filling point, oil sight glasses, oil discharge points, condensate drain, exhaust silencer, absolute pressure sensor, solenoid valve, frequency converter, control box, Emergency Stop switch, touchscreen (HMI), vacuum pump VLR 1000, non-return valve, inlet flange.
- Control unit maintains setpoint pressure by reducing speed to minimum, then switching off drive if setpoint not reached for a certain time; restarts when setpoint exceeded.
- Fields of application: evacuation of closed systems or continuous vacuum within inlet pressure range 200–700 mbar (abs).
- Maximum suction capacity 950 m³/h at 50 Hz; maximum permissible back pressure +50 mbar.
- Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits; contact manufacturer.
This section covers preparation of installation, installation conditions, pipe connection, oil level check, and electrical connection. It includes requirements for clearance, cooling air, back pressure, and pipe forces.
- Machine must be set up horizontally (max. inclination 5° in all directions).
- Ambient temperature min. +5 °C, max. +40 °C.
- Cooling air inlets/outlets at least 30 cm from adjacent walls; maintenance clearance at least 40 cm around compressor.
- Maximum permissible back pressure: +50 mbar; no blocking devices in air outlet line.
- Only screw in pipes by hand; use flexible connections if necessary.
- Long connecting lines >3 m can cause reverse rotation; do not dismount or change integrated non-return valve.
- Output reduction noticeable when installed at more than 1000 m above sea level.
This section covers installation check, initial commissioning, operation via touchscreen (navigation, password, PID, process display, general settings, timer, software update, condensate discharge), decommissioning, storing, and recommissioning.
- Operation includes navigation and status line, password (user management), PID commissioning, process main display, general settings, timer, software update, discharge condensate (after-run).
- Decommissioning and storing procedures are described.
- Recommissioning after storage is covered.
This section covers ensuring operational safety, maintenance table, preparing maintenance works, oil change/oil check, cleaning of vacuum pump, air filtering, motor and coupling, integrated frequency converter, control unit and safety-relevant IAC devices, repair and service, and spare parts.
- Maintenance table and intervals are provided.
- Oil level check and oil change procedures.
- Cleaning of vacuum pump and air filtering.
- Motor, coupling/fan, and integrated frequency converter maintenance.
- Control unit and safety-relevant IAC devices.
- Repair and service only by authorized workshops using original spare parts.
This section contains a table of malfunctions with causes and remedies. It covers symptoms such as machine switched off by motor protection switch, pump does not start, insufficient suction capacity, final pressure not reached, pump gets too hot, strange noise, pump switches off, display remains dark, and utilisation continuously at 100% or 25%.
- Never put the vacuum pump in operation again after automatic shut-off without finding and remedying the reason.
- Table includes malfunction, cause, elimination, and note columns.
- Contact customer service if malfunctions cannot be localised or eliminated.
This section provides technical data for the central vacuum unit. The specific data is referenced to chapter 10 on page 45, but the extracted text does not include the detailed table.
- Technical data is located in chapter 10 on page 45.
- Data plate information includes model, year of construction, serial number, article number, motor output, suction capacity, final pressure, frequency range, speed range, operating mode.
This section provides a maintenance overview. The specific content is referenced to chapter 11 on page 46, but the extracted text does not include the detailed table.
- Maintenance overview is located in chapter 11 on page 46.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ambient temperature for operation: 0 to 40 °C; inlet temperature: 5 to 40 °C. p.9 ↗ | Ensure installation environment stays within these limits; contact manufacturer for temperatures outside this range. | C-VLR 1000 HV+ |
| Maximum permissible back pressure on outlet side: +50 mbar. p.18 ↗ | Do not install blocking devices in the air outlet line; ensure exhaust line does not exceed this back pressure. | C-VLR 1000 HV+ |
| Maximum suction capacity with unrestricted suction: 950 m³/h at 50 Hz. p.18 ↗ | Use this value for sizing system capacity at 50 Hz operation. | C-VLR 1000 HV+ |
| Inlet pressure range for continuous vacuum: 200–700 mbar (abs). p.18 ↗ | Operate within this range for continuous vacuum applications. | C-VLR 1000 HV+ |
| Machine must be set up horizontally with max. inclination 5° in all directions. p.19 ↗ | Ensure floor is plane and even; secure against tipping. | C-VLR 1000 HV+ |
| Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; maintenance clearance at least 40 cm around compressor. p.19 ↗ | Provide sufficient space for cooling and maintenance access. | C-VLR 1000 HV+ |
| Storage temperature: -20 °C to +70 °C; relative air humidity max. 80%; do not store for more than 6 months. p.14 ↗ | Follow storage conditions to prevent damage; refer to info sheet I 150 for longer storage. | C-VLR 1000 HV+ |
| Max. inclination during transport: 10° in all directions. p.13 ↗ | Secure machine during transport and avoid exceeding this inclination. | C-VLR 1000 HV+ |
| Long connecting lines of more than 3 m can cause reverse rotation of the machine. p.20 ↗ | Do not dismount or change the integrated non-return valve; check it regularly for proper functioning. | C-VLR 1000 HV+ |
| Output reduction noticeable when installed at more than 1000 m above sea level. p.20 ↗ | Contact manufacturer for high-altitude installations. | C-VLR 1000 HV+ |
| Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits. p.18 ↗ | Contact manufacturer for such operating conditions. | C-VLR 1000 HV+ |
| Emergency Stop switch stops all rotating parts immediately; control unit remains active. No own Emergency Off; must be implemented by user. p.12 ↗ | Integrate central vacuum unit into user's safety concept for Emergency Off. | C-VLR 1000 HV+ |
| Data plate includes model C-VLR 1000 (29), ID: 102781F001, final pressure 200 mbar(abs.), suction capacity 475/950 m³/h, speed 1497/2945 1/min, motor power 9.25/18.50 kW at 25/50 Hz. p.17 ↗ | Use data plate for verification of specific unit specifications. | C-VLR 1000 HV+ |
| Only screw in pipes by hand; use flexible connections if necessary to avoid excessive forces and torques. p.20 ↗ | Prevent damage to machine from pipe forces. | C-VLR 1000 HV+ |
| User must install appropriate filters before the vacuum connection to clean inlet air. p.20 ↗ | Prevent particles from damaging internal components and reducing performance. | C-VLR 1000 HV+ |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| The machine is switched off by the motor protection switch p.42 ↗ | Mains voltage / Frequency does not correspond with the motor data | Check by qualified electrician | Chapter 5.5 |
| The machine is switched off by the motor protection switch p.42 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Chapter 5.5 |
| The machine is switched off by the motor protection switch p.42 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Chapter 5.5 |
| The machine is switched off by the motor protection switch p.42 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1) | |
| The machine is switched off by the motor protection switch p.42 ↗ | Wrong direction of rotation of the motor. | Check the rotation direction. | Elmo Rietschle Service |
| Pump does not start p.42 ↗ | The Emergency Stop switch has been actuated | Unlock the Emergency Stop switch | Chapter 6.2 |
| Pump does not start p.42 ↗ | Release switch not switched on | Switch on release switch | |
| Pump does not start p.42 ↗ | Malfunction of the frequency converter | Check the status LED on the frequency converter. If necessary, disconnect the converter from the power supply for 30 s | Operating instructions of the frequency converter |
| Pump does not start p.42 ↗ | Pressure below setpoint value | Wait until pressure has reached the minimum pressure and restarts automatically. If necessary, ventilate system. | Chapter 4.2 |
| Suction capacity is insufficient p.42 ↗ | Micro filter is dirty | Clean / replace the micro filter | Chapter 7.6 |
| Suction capacity is insufficient p.42 ↗ | The inlet pipe is too long or too narrow | Check the hose and/or the pipe | Chapter 5.3 |
| Suction capacity is insufficient p.42 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | – |
| Suction capacity is insufficient p.42 ↗ | Pressure sensor wrongly scaled | Re-scale pressure sensor | Elmo Rietschle Service |
| Suction capacity is insufficient (continued) p.43 ↗ | Solenoid valve opens too early | Adapt limit value of solenoid valve (it is too near to the setpoint value). | Chapter 6.3.3 |
| Suction capacity is insufficient (continued) p.43 ↗ | Wrong direction of rotation of the motor. | Check the rotation direction. | Elmo Rietschle Service |
| Suction capacity is insufficient and pump runs at maximum speed p.43 ↗ | Too high demand. | Reduce number of consumers or check system for leaks | – |
| Final pressure (max. vacuum) is not reached p.43 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | – |
| Pump gets too hot p.43 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Pump gets too hot p.43 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.2 |
| Pump gets too hot p.43 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.5 |
| The machine makes a strange noise p.43 ↗ | Deposits on the rotary piston | Clean the working space and the rotary piston | Elmo Rietschle Service |
| Pump switches off p.43 ↗ | Pump starts too fast and reports error | Check run-up time, depends on demand | – |
| Pump switches off p.43 ↗ | Pump gets too hot | Check number of starts/stops | Chapter 4.4 |
| Pump switches off p.43 ↗ | Maximum pressure exceeded | Wait until pressure has reached the maximum value and restarts automatically. | – |
| Display remains dark p.43 ↗ | Power supply of display disconnected | Check voltage of display | Chapter 5.5 |
| Display remains dark p.43 ↗ | Power supply of display disconnected | Check the fuse in the control box and replace, if necessary | Chapter 5.5 |
| Display remains dark p.43 ↗ | Power supply of display disconnected | Check the switch-mode power supply in the control box | – |
| Display remains dark p.43 ↗ | Display defective | Replace display | Elmo Rietschle Service |
| Utilisation continuously at 100% p.43 ↗ | Pump capacity too low | Install a pump with higher capacity | Elmo Rietschle Service |
| Utilisation continuously at 100% p.43 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | – |
| Utilisation continuously at 25% p.43 ↗ | Pump capacity too high | Install a pump with lower capacity | Elmo Rietschle Service |