COMBI RD 1002 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum COMBI RD vacuum pump unit series datasheet covering three variants: COMBI RD 1002 (HiLobe 1302 booster + DuoVane 135 backing pump), COMBI RD 1604 (HiLobe 2104 + DuoVane 135), COMBI RD 2054 (HiLobe 2704 + DuoVane 300). Also lists accessories, spare parts and options.
Section-by-Section Technical Breakdown
Describes the COMBI RD vacuum pump unit as reliable, high-performance and flexible. Reliability comes from process monitoring via integrated sensors and an intelligent user interface; performance from high pumping speed at low ultimate pressures, fast pump-down and high energy efficiency. Flexibility comes from combinations of oil-lubricated two-stage rotary vane backing pumps and vacuum boosters.
- High uptime and increased safety thanks to process monitoring via integrated sensors
- Intelligent user interface on the vacuum booster
- High pumping speed at low ultimate pressures, fast pump-down times, high energy efficiency
- Various design options and combinations of backing pumps and boosters available
Lists available accessories and options for the COMBI RD series, including control and monitoring units, filters, separators, gas-ballast kit and mounting feet options.
- Control unit for booster and backing pump
- Oil mist separator; OFC (chemical oil filter); OFM (mechanical oil filter)
- Gas-ballast valve kit
- Operations monitoring unit
- SAS (dust separator); KAS (condensate separator)
- Feet options: height-adjustable machine foot, castor wheels, floor mounting
Performance and interface data table for the three COMBI RD models, including pumping speed, ultimate pressure (with/without gas ballast), power consumption, voltage, noise level, weight, and flange connections.
- COMBI RD 1002: 975 m³/h pumping speed at 1 hPa; ultimate pressure 5·10⁻⁴ hPa (9·10⁻⁴ hPa with gas ballast); 6.5 kW max; 500 kg
- COMBI RD 1604: 1644 m³/h at 1 hPa; ultimate pressure 9·10⁻⁴ hPa (2·10⁻³ hPa with gas ballast); 11 kW max; 650 kg
- COMBI RD 2054: 2037 m³/h at 1 hPa; ultimate pressure 9·10⁻⁴ hPa (2·10⁻³ hPa with gas ballast); 11 kW max; 790 kg
- All models: 400 V AC (±10%), 50 Hz; noise level ≤75 dB(A) per ISO 2151 at 1 hPa
- Gas inlet/outlet: RD 1002 DN 100 ISO-F/PN 16 / DN 63 ISO-F; RD 1604 DN 100 ISO-F/PN 16 / DN 100 ISO-F; RD 2054 DN 160 ISO-F/PN 16 / DN 100 ISO-F
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| COMBI RD 1002 delivers 975 m³/h pumping speed at 1 hPa with ultimate pressure 5·10⁻⁴ hPa (mbar) p.2 ↗ | Suitable for the smallest duty of the series; best ultimate pressure of the range, useful for processes needing low base pressure without gas ballast | COMBI RD 1002 |
| COMBI RD 1604 delivers 1644 m³/h at 1 hPa; COMBI RD 2054 delivers 2037 m³/h at 1 hPa p.2 ↗ | Roughly doubles RD 1002 capacity; select based on required pump-down time and chamber volume | COMBI RD 1604 / 2054 |
| Ultimate pressure degrades with gas ballast: RD 1002 from 5·10⁻⁴ to 9·10⁻⁴ hPa; RD 1604/2054 from 9·10⁻⁴ to 2·10⁻³ hPa p.2 ↗ | Use the gas-ballast valve kit only when condensate/vapor handling is required; expect a factor ~2 worse base pressure | whole series |
| Max power consumption is 6.5 kW (RD 1002) and 11 kW (RD 1604 and RD 2054) p.2 ↗ | Size electrical supply and breakers accordingly; note RD 1604 and RD 2054 share the same power rating despite different pumping speeds | whole series |
| Input voltage is 400 V AC ±10% at 50 Hz for all models p.2 ↗ | Requires a three-phase 400 V/50 Hz supply; ±10% tolerance defines acceptable grid variation | whole series |
| Noise level ≤75 dB(A) (ISO 2151) at 1 hPa for all models p.2 ↗ | Workplace noise planning can assume ≤75 dB(A) under the stated condition; typically still warrants hearing protection assessment | whole series |
| Approximate weights: 500 kg (RD 1002), 650 kg (RD 1604), 790 kg (RD 2054) p.2 ↗ | Plan lifting equipment, floor loading and mounting feet (height-adjustable feet, castors, or floor mounting) accordingly | whole series |
| Gas inlet/outlet flanges: RD 1002 DN 100 ISO-F/PN 16 in, DN 63 ISO-F out; RD 1604 DN 100 ISO-F/PN 16 in, DN 100 ISO-F out; RD 2054 DN 160 ISO-F/PN 16 in, DN 100 ISO-F out p.2 ↗ | Match inlet piping and pressure-rated (PN 16) connections to the specific model; RD 2054 needs DN 160 inlet hardware | model-specific |
| Backing pumps used: DuoVane 135 (RD 1002 and RD 1604) and DuoVane 300 (RD 2054); boosters: HiLobe 1302/2104/2704 respectively p.2 ↗ | Spare parts and service kits must match the specific booster/backing pump combination, not just the COMBI RD model number | model-specific |
| Optional accessories include OFC chemical oil filter and OFM mechanical oil filter p.1 ↗ | Choose OFC for chemically contaminated processes, OFM for particulate/purely mechanical duty | whole series |
| SAS dust separator and KAS condensate separator are available as options p.1 ↗ | Fit SAS for dusty processes and KAS when condensate is expected at the exhaust to protect the backing pump | whole series |
| An operations monitoring unit and a control unit for booster and backing pump are offered as options p.1 ↗ | For unmanned or safety-critical installations, integrate these to exploit the unit's sensor-based process monitoring | whole series |