The SciVario® twin is a benchtop bioreactor control system that operates two independent glass or single-use bioreactors in parallel, with a working volume range of 60 mL to 40 L. This cell-culture configuration is supplied with a 2.5 L vessel (order no. 76DR03C) and is distinguished within the series by its dedicated cell-culture vessel kit. It serves as the control and drive platform for parallel small- and bench-scale cultivation runs.
Full specifications
Description
Construction and positioning
- The SciVario twin is a benchtop control system, not a standalone vessel: it drives and controls two bioreactors simultaneously, each of which may be glass or single-use.
- The series spans working volumes from 60 mL to 40 L and offers drive variants FI30, MD30, MD40, TB200 and TB200 high; the cell-culture configuration documented here is supplied with a 2.5 L vessel (order no. 76DR03C).
- A modular bay-drawer architecture houses the control and drive hardware, allowing the unit to be configured per reactor type.
- Sibling configurations in the same series use 3.5 L vessels; the 2.5 L cell-culture kit is the defining element of this modification.
Behavior and operating envelope
- Because the platform covers 60 mL to 40 L working volume, the applicable volume for any run is set by the installed vessel and drive variant, not by the control unit alone.
- Parallel operation of two reactors means two independent process trains share one benchtop footprint; each reactor's parameters are controlled separately.
- No digitized performance curves or rated setpoint ranges were supplied for this configuration, so temperature, agitation and gas-mixing performance cannot be stated here.
Installation, connection and control
- The unit is benchtop-mounted and requires the vessel kit (listed with individual order numbers) to be assembled onto the selected drive variant before operation.
- Drive variant selection (FI30, MD30, MD40, TB200, TB200 high) must match the vessel and application; the control system is common across variants.
- Detailed electrical ratings, interface protocols and control-loop specifications were not included in the supplied document digests and are therefore not stated.
Integration & Operating Notes
The 60 mL – 40 L range is a platform envelope spanning all vessel and drive combinations. For this cell-culture configuration the installed 2.5 L vessel defines the actual working volume; running outside the installed vessel's rated fill invalidates mixing and aeration assumptions.
Parallel control of two bioreactors means the bench must accommodate two vessel assemblies plus the control unit and its bay drawers. Plan bench depth and access for vessel handling on both sides before specifying the installation.
The 2.5 L cell-culture vessel kit is itemized with its own order numbers and is not implied by the control-unit order alone. Confirm the complete kit list against the technical data document before placing the order to avoid missing components at installation.
Five drive variants (FI30, MD30, MD40, TB200, TB200 high) exist across the series. The selected drive determines the mechanical interface to the vessel, so it should be fixed before control and I/O configuration is finalized.
Selection & Integration Q&A
Pick the 2.5 L kit (order no. 76DR03C) when cell-culture runs need the smaller working volume; the 3.5 L vessel variant suits larger bench-scale batches. Both use the same twin control platform, so the choice is vessel volume and kit contents, not controller capability.
The vessel kit is itemized with individual order numbers and is not part of the base control unit. Specify the 2.5 L cell-culture vessel kit and the matching drive variant (FI30, MD30, MD40, TB200 or TB200 high) together with the control system.
The platform supports parallel control of two bioreactors, glass or single-use, within a 60 mL – 40 L working volume range. Each reactor's vessel and drive must be specified individually, and the bench must fit two vessel assemblies plus the control unit.
The technical data document lists the 2.5 L vessel kit contents with individual order numbers, indicating kit components are ordered separately from the control unit. Verify the full kit list before ordering; cables and accessories beyond the listed kit are not confirmed in the supplied documents.