Nabertherm HG 5208/S
Nabertherm HG 5208/S — Fusing.
The HG 5208/S is a top-hat fusing furnace with wire heating and a fixed table, built for 3-phase industrial power and a maximum temperature of 900 °C. Its 3100 × 2100 × 800 mm inner chamber and 5000 kg mass distinguish it as a large-format modification within the series. It is intended for batch fusing and heat-treatment processes requiring overhead access to the load.
Full specifications
| Electrical connection | 3-phase |
| Heating power | 110 watt |
| Floor space mfr | 6.51 |
| Inner dimensions (W × D × H) mfr | 3100 × 2100 × 800 mm |
| Outer dimensions (W × D × H) mfr | 3990 × 2590 × 3140 mm |
| Weight | 5000 kg |
| Max temperature | 900 °C |
Description
Construction and series positioning
- Top-hat architecture with wire heating elements and a fixed table; the chamber is formed by the inner dimensions 3100 × 2100 × 800 mm (W × D × H).
- Outer envelope 3990 × 2590 × 3140 mm and 5000 kg weight indicate a stationary, floor-mounted installation with substantial structural footprint (6.51 floor-space units as listed).
- No sibling models are provided for this series, so positioning is limited to the stated large-format dimensions and 900 °C class.
Thermal behavior and media
- Maximum temperature is 900 °C; no curve points or heating-rate data are supplied, so no ramp or uniformity behavior can be asserted.
- The matched electrical spec lists 110 W heating power alongside a 3-phase connection; these two values are not reconcilable for a furnace of this size and are therefore not presented as a performance rating.
Control and operation
- The attached controller document covers the Nabertherm 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but contains no model-specific wiring or setpoint tables for the HG 5208/S.
- No installation, connection or operating instructions specific to this model are present in the supplied digests; integration details must be taken from the model-specific manual, which is not included here.
Integration & Operating Notes
The 5000 kg mass and 3990 × 2590 mm outer footprint require a structural assessment of the installation floor before placement. The top-hat design also needs vertical clearance for the lift path, which is not documented in the supplied digests.
The controller digest describes the 500 series and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but gives no model-specific configuration for the HG 5208/S. Controller selection and thermocouple wiring must be confirmed against the furnace order documentation.
Selection & Integration Q&A
Choose it when the load fits the 3100 × 2100 × 800 mm chamber and process temperature stays at or below 900 °C. No sibling models are supplied, so comparison against other sizes cannot be made from the available facts.
A 3-phase supply is confirmed, but the listed 110 W heating power is not usable for sizing; take the connected load from the nameplate. The controller platform (500 series / MyNabertherm) is documented separately and must be matched to the furnace order.
The 5000 kg mass and 3990 × 2590 mm outer footprint demand a verified floor load capacity. The top-hat lift requires vertical clearance above the unit; the supplied documents give no clearance or ambient-temperature figures, so these must come from the model manual.
No maintenance intervals, error codes or consumables are specified in the supplied digests. The controller document mentions recorder and instrumentation options but no included accessories; the base-delivery scope and service plan must be confirmed from the order documentation.