Nabertherm KTR 4500 LS
Nabertherm ·Made in Germany · In Active Production

Nabertherm KTR 4500 LS

Nabertherm KTR 4500 LS — Heating Cabinets Chamber Ovens.

The KTR 4500 LS is a 4500-litre chamber oven with safety technology per EN 1539, rated to 260 °C and built for solvent-laden loads. Its 1500 × 1500 × 2000 mm chamber and 520-unit exhaust flow distinguish this LS modification from standard KTR ovens. It serves as a process oven for drying and heat treatment where solvent concentration must be controlled.

Full specifications

Core Performance & Functional Specifications
Chamber volume 4500 l
Heating power 54 watt
Exhaust air volumetric flow rate mfr 520
Inner dimensions (W × D × H) mfr 1500 × 1500 × 2000 mm
Outer dimensions (W × D × H) mfr 2445 × 1930 × 3510 mm
Operating Conditions, Environment & Protection
Max temperature 260 °C

Description

Construction and series positioning

The KTR 4500 LS belongs to the Nabertherm KTR chamber oven line, which the fiber-optics catalog section lists up to 260 °C. The LS suffix denotes safety technology per EN 1539, a configuration intended for loads that release flammable solvents. The chamber measures 1500 × 1500 × 2000 mm (W × D × H), giving 4500 l of usable volume; the outer envelope is 2445 × 1930 × 3510 mm. No sibling models are listed in the verified facts, so sizing comparisons within the series cannot be made from this data set.

Thermal and process behavior

Maximum temperature is 260 °C. The matched heating-power entry reads 54 watt, which is not physically consistent with a 4500-l chamber and is therefore omitted from this overview rather than reconciled. No digitized curve points were supplied, so heat-up and uniformity behavior cannot be characterized. The safety concept is quantified by the solvent tables: the maximum permissible solvent mass falls as temperature rises, from 557 g at the lowest listed temperature step down through 266, 161, 105, 85, 82 and 71 g at the highest. These figures define the allowable load per batch and must be read against the actual process temperature, not the oven maximum.

Air and exhaust path

An exhaust air volumetric flow rate of 520 is listed without a unit in the source; the value is reproduced as given. This exhaust capacity is the basis for diluting solvent vapor below hazardous concentration and works together with the solvent mass limits above. No inlet-air or purge-pressure data are present in the verified facts.

Control and documentation

The attached document digests cover Nabertherm controller series 500 and the MyNabertherm app, process-data storage, and AMS2750F instrumentation types, but they contain no actionable engineering facts and no model-specific wiring or commissioning data. Installation, connection and control specifics for the KTR 4500 LS therefore cannot be stated from the verified material and must be taken from the model-specific operating manual.

Integration & Operating Notes

Process Limits
Solvent charge must be reduced as process temperature rises

The permissible solvent mass per batch drops from 557 g at the lowest listed temperature to 71 g at the highest. Exceeding the value for the actual setpoint creates an explosive atmosphere inside the 4500-l chamber; the limit is set by the EN 1539 safety concept, not by product quality.

Factory Specification Sheet, solvent mass table
Process Limits
Exhaust flow of 520 must be maintained during solvent processing

The listed exhaust air volumetric flow rate of 520 (unit as printed in the source) is the dilution basis for the solvent limits. If the exhaust path is restricted or the duct is undersized, vapor concentration rises even when the batch solvent mass is within the table, so the exhaust duct and any connected extraction system must be sized to sustain this flow.

Factory Specification Sheet, exhaust air volumetric flow rate
Electrical
Heating power cannot be taken from the supplied spec table

The matched heating-power entry of 54 watt is inconsistent with a 4500-l chamber at 260 °C and is omitted. Electrical supply rating, connection type and protective devices must be read from the model-specific nameplate and operating manual before the supply circuit is designed; do not size cabling from the verified facts in this card.

Factory Specification Sheet, heating power entry (inconsistent, omitted
Control & I/O
Controller documentation supplied does not cover this model

The attached controller digest describes series 500 functions, MyNabertherm app connectivity, process-data storage and AMS2750F instrumentation types, but contains no actionable facts and no KTR 4500 LS wiring or commissioning data. Control architecture, sensor type and interface assignment must be confirmed against the oven's own manual and wiring diagram.

Prozesssteuerung englisch, document digest

Selection & Integration Q&A

When should the KTR 4500 LS be chosen instead of a standard KTR chamber oven without LS?

Choose the LS version when the load releases flammable solvents and the process must comply with EN 1539; the solvent mass table and 520 exhaust flow are the safety basis. A non-LS KTR is appropriate only for solvent-free drying and heat treatment at up to 260 °C.

What must be verified on the exhaust and extraction side before commissioning this oven?

The exhaust air volumetric flow rate is listed as 520 (unit as printed). The connected extraction duct must sustain this flow, since the permissible solvent masses (557 g down to 71 g depending on temperature) assume that dilution. Undersized ducting invalidates the safety margin.

What maintenance and consumable items are not defined by the supplied documentation?

The verified facts list no maintenance intervals, spare parts, cables or accessories, and the controller digest contains no actionable service data. Service schedules, exhaust filter media and controller options must be taken from the model-specific operating manual, not from this card.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF