Nabertherm LH 60/13
Nabertherm LH 60/13 — Radiation Heating.
The LH 60/13 is a 60-litre chamber furnace with brick insulation, rated to 1300 °C and powered by a 3-phase connection. Its 400 × 400 × 400 mm chamber distinguishes it from the 120-litre LH 120/12 and the 1400 °C LF 60/14 siblings. It serves as a general-purpose radiation-heating unit for batch heat treatment in laboratory and production settings.
Nabertherm Chamber Furnaces with Brick Insulation or Fiber Insulation | Nabertherm Series — Model Comparison & Selection
Full specifications
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Chamber volume | 60 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Connected mfr | 11 |
| Inner dimensions (W × D × H) mfr | 400 × 400 × 400 mm |
| Outer dimensions (W × D × H) mfr | 790 × 1180 × 1370 mm |
| Weight | 300 kg |
| Weight | 300 kg |
| Weight | 300 kg |
| Weight | 300 kg |
| Max temperature | 1300 °C |
| Max temperature | 1300 °C |
| Max temperature | 1300 °C |
| Max temperature | 1300 °C |
Description
Construction and series positioning
- The LH 60/13 is a chamber furnace with brick insulation, the 60-litre member of the LH series. Its chamber measures 400 × 400 × 400 mm (W × D × H), giving a cubic working volume of 60 l.
- Within the series, the LH 120/12 offers a larger 120-litre chamber but a lower 1200 °C maximum, while the LF 60/14 shares the 60-litre size but uses fiber insulation and reaches 1400 °C. The LH 60/13 therefore occupies the middle ground: brick insulation for thermal stability and a 1300 °C ceiling.
- The outer enclosure measures 790 × 1180 × 1370 mm (W × D × H) and the unit weighs 300 kg, indicating a floor-standing or bench-mounted installation with substantial mass.
Heating and electrical behavior
- Heating is by radiation from the chamber walls; the maximum working temperature is 1300 °C. The electrical connection is 3-phase, with a connected load listed as 11 (unit not stated in the source; verify against the nameplate before sizing supply conductors).
- No digitized curve points or cooling-rate data are available for this model, so thermal response under load cannot be quantified from the supplied facts.
Control and operation
- The attached controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process data storage and temperature uniformity instrumentation per AMS2750F. These controller functions are available as part of the broader product system, but the base furnace delivery configuration is not specified in the provided digests.
- No model-specific installation, connection, or operating instructions were found in the attached PDF digests; the documents cover other product lines (dental, foundry, fiber optics glass) and general controller functions.
Integration & Operating Notes
The extra specification lists 'Connected' as 11 with no unit. This value could be kW or amperes per phase; the supply cable, breaker, and disconnect must be sized only after verifying the unit on the nameplate or factory wiring diagram. A 3-phase feed is required.
The maximum temperature is 1300 °C. Exceeding this limit risks damage to the brick insulation and heating elements. No separate control thermocouple or over-temperature protection specification is provided in the facts; the controller documentation covers general 500-series functions but not a model-specific limit device.
The Prozesssteuerung document describes 500-series controllers and the MyNabertherm app, including process data storage and AMS2750F instrumentation types. These functions are not confirmed as included in the base LH 60/13 delivery; specify the desired controller and recorder options at order.
Selection & Integration Q&A
Choose the LH 60/13 for a 60-litre chamber at up to 1300 °C with brick insulation. The LH 120/12 gives double the volume but only 1200 °C; the LF 60/14 gives the same 60 litres but 1400 °C with fiber insulation. Pick LH 60/13 when 1300 °C is sufficient and brick thermal mass is preferred.
A 3-phase supply is required. The connected load is listed as '11' without a unit, so the actual kW or full-load amperes must be read from the nameplate before selecting cable gauge, fuses, and a local disconnect. Do not assume the value is kW or amperes until verified.
The supplied facts do not list a maintenance schedule, spare parts, or included accessories. Controller options (500 series, MyNabertherm app, recorders) are documented separately and may not be part of the base furnace. Heating elements and thermocouples are consumables; their replacement intervals are not specified here and must be obtained from Nabertherm service documentation.