Nabertherm NA 1500/45
Nabertherm NA 1500/45 — Forced Convection.
The NA 1500/45 is a forced-convection chamber furnace with a 1500-litre chamber (1000 × 1500 × 1000 mm) and a maximum temperature of 450 °C, electrically heated via a 3-phase connection. Its 3600 circulation and 36 heating values distinguish it within the series, where the N 1500/85HA offers higher temperature and the NA 4000/45 larger volume. It is intended for uniform heat treatment of large loads in industrial processes.
Full specifications
| Chamber volume | 1500 l |
| Chamber volume | 1500 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Circulation mfr | 3600 |
| Heating mfr | 36 |
| Inner dimensions (W × D × H) mfr | 1000 × 1500 × 1000 mm |
| Outer dimensions (W × D × H) mfr | 2015 × 2650 × 1700 mm |
| Max temperature | 450 °C |
| Max temperature | 450 °C |
Description
Construction and positioning
- The NA 1500/45 is a forced-convection chamber furnace from Nabertherm's series of electrically heated units from 1000 litres upward. Its chamber measures 1000 × 1500 × 1000 mm (W × D × H), giving a volume of 1500 litres, and the outer dimensions are 2015 × 2650 × 1700 mm.
- Within the series, the NA 1500/45 is the 1500-litre model with a 450 °C maximum temperature. The sibling N 1500/85HA shares the 1500-litre class but reaches 850 °C, while the NA 4000/45 offers a larger 4000-litre chamber at the same 450 °C limit. The NA 1500/45 therefore sits between them in size and is suited to processes that require forced air circulation at moderate temperatures.
Behavior and media
- The furnace is electrically heated and connected to a 3-phase supply. The extra specifications list a circulation value of 3600 and a heating value of 36; these are factory figures without units and are not interpreted here as ratings. No performance curves or temperature-uniformity data are provided in the verified facts, so load-dependent behavior cannot be quantified from this sheet.
- The maximum operating temperature is 450 °C. Operation above this limit is not supported by the verified data.
Installation, control and operation
- The attached document digests do not contain model-specific installation or control details for the NA 1500/45. The controller document covers Nabertherm's standard 500-series controllers and the MyNabertherm app, including process data storage and AMS2750F instrumentation types, but does not name this furnace model. No wiring diagrams, connection schedules or operating sequences for the NA 1500/45 are available in the supplied facts.
Integration & Operating Notes
The furnace is specified for a 3-phase electrical connection. The verified facts do not state voltage, current or power, so the site supply and protective devices must be confirmed against the nameplate and Nabertherm's project documentation before installation.
The maximum temperature is 450 °C. Operating above this limit is outside the verified specification and may damage the furnace or invalidate process results. Temperature control setpoints and over-temperature protection should be configured accordingly.
Nabertherm's controller documentation covers the 500-series and MyNabertherm app, including process data storage and AMS2750F instrumentation types, but does not specify which controller is fitted to the NA 1500/45. Confirm the delivered control configuration and any recorder options with the order documentation.
Selection & Integration Q&A
Choose the NA 1500/45 for a 1500-litre load at up to 450 °C with forced convection. The N 1500/85HA is the 1500-litre alternative when higher temperature is needed; the NA 4000/45 is the larger 4000-litre chamber at the same 450 °C limit.
A 3-phase electrical supply is required; voltage, current and power are not stated in the verified facts and must be taken from the nameplate and project documentation. The controller is not specified in the supplied documents, so the control cabinet and any process-data recording must be confirmed with Nabertherm.
The supplied documents contain no maintenance intervals, error codes or accessory lists for the NA 1500/45. Consumables, cables and controller options are not described in the verified facts and should be requested from Nabertherm as part of the order specification.