The NAT 30/65 is a tabletop forced-convection chamber furnace with a 30-litre chamber (320 × 320 × 300 mm) and a maximum working temperature of 650 °C, electrically heated from a single-phase supply. Within the NAT series it is the 650 °C modification with the smallest chamber, distinguished from the 850 °C siblings (NAT 15/85, NAT 30/85, NAT 50/85) by its lower ceiling temperature. It is intended for uniform low-to-medium temperature heat treatment of small batches in laboratory and process environments.

Full specifications

Core Performance & Functional Specifications
Chamber volume 30 l
Chamber volume 30 l
Chamber volume 30 l
Electrical connection 1-phase
Electrical connection 1-phase
Electrical connection 1-phase
Heating mfr 3,0
Heat-up time3 mfr 80
Inner dimensions (W × D × H) mfr 320 × 320 × 300 mm
Outer dimensions (W × D × H) mfr 810 × 620 × 620 mm
Dimensions, Weight & Mechanical Design
Weight 90 kg
Weight 90 kg
Weight 90 kg
Operating Conditions, Environment & Protection
Max temperature 650 °C
Max temperature 650 °C
Max temperature 650 °C

Description

Construction and series positioning

Thermal behaviour

Control and operation

Integration & Operating Notes

Process Limits
Do not exceed 650 °C even briefly

The maximum temperature of this modification is 650 °C. The 850 °C siblings in the same series have a different thermal design; operating the NAT 30/65 above its rated ceiling risks damage to the heating elements and chamber insulation and invalidates any uniformity data.

Factory Specification Sheet
Control & I/O
Controller and documentation options are ordered separately

Controller series 500 functions, process data storage and MyNabertherm app connectivity are described in a separate controller document and are not part of the base furnace facts. Specify the controller, instrumentation type and any recorder explicitly on the order.

Nabertherm Prozesssteuerung (controller) document

Selection & Integration Q&A

When should I choose the NAT 30/65 instead of the NAT 30/85 or NAT 15/85?

Choose the NAT 30/65 when 650 °C is sufficient and a 30-litre chamber fits the load. The NAT 30/85 offers the same chamber volume at 850 °C; the NAT 15/85 is the smaller 850 °C unit. The NAT 50/85 is for larger loads at 850 °C.

What supply and control hardware must be provided around the NAT 30/65?

A single-phase supply sized from the nameplate, plus a controller from the Nabertherm series 500 range if process data storage or app connectivity is required. The controller and any recorder are separate items; the furnace facts do not define a built-in control interface.

What is included in base delivery and what must be ordered separately?

The supplied facts list only the furnace itself: 30-litre chamber, 650 °C maximum, single-phase connection, 90 kg. Controllers, recorders, the MyNabertherm app link and any instrumentation for temperature uniformity are documented separately and are not confirmed as part of the base delivery.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF