| Temperature range |
-40...180 °C
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Temperature uniformity dependent on set |
0.1...1.8 ± K
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Temperature fluctuation dependent on set |
0.1...0.5 ± K
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Cooling down time from 180°C to -40°C |
120 min
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Temperature range with humidity |
10...95 °C
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Humidity range |
10...98 % RH
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Max. heat compensation at 25°C and 90% RH |
1,000 W
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Rated voltage |
400 V
p.3 ↗ |
MKF720-400V |
| Rated voltage |
480 V
p.3 ↗ |
MKF720-480V-C |
| Power frequency |
50 Hz
p.3 ↗ |
MKF720-400V |
| Power frequency |
60 Hz
p.3 ↗ |
MKF720-480V-C |
| Nominal power |
11 kW
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Unit fuse |
32,0 A
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Phase (nominal voltage) |
3~/N/PE
p.3 ↗ |
MKF720-400V |
| Phase (nominal voltage) |
3~
p.3 ↗ |
MKF720-480V-C |
| Interior volume |
734 L
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Net weight of the unit (empty) |
590 kg
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Load per rack |
40 kg
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Permitted load |
160 kg
p.3 ↗ |
MKF720-400V and MKF720-480V-C |
| Sound-pressure level |
65 dB(A)
p.4 ↗ |
MKF720-400V |
| Sound-pressure level |
67 dB(A)
p.4 ↗ |
MKF720-480V-C |
| Energy consumption at 25°C and 60% RH |
3,000 Wh/h
p.4 ↗ |
MKF720-400V and MKF720-480V-C |
| Number of shelves (std./max.) |
1/11
p.4 ↗ |
MKF720-400V and MKF720-480V-C |
| Width net |
1,580 mm
p.4 ↗ |
MKF720-400V and MKF720-480V-C |
| Height net |
2,005 mm
p.4 ↗ |
MKF720-400V and MKF720-480V-C |