Data Sheet Model MKT 115
Technical Reference Summary
Covered Models & Document Scope
Cámara climática dinámica BINDER MKT 115 para cambios rápidos de temperatura con rango de baja temperatura ampliado, volumen interior de 115 L. Dos variantes: MKT115-400V (estándar, 400 V 3~/N/PE 50 Hz, Art.-N.º 9020-0385) y MKT115-480V-C (con convertidor de tensión y frecuencia, 480 V 3~ 60 Hz, Art.-N.º 9020-0363).
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Temperature range | -70...180 °C p.2 ↗ | MKT115-400V |
| Temperature range | -70...180 °C p.2 ↗ | MKT115-480V-C |
| Temperature uniformity dependent on set value | 0.2...1.8 ± K p.2 ↗ | MKT115-400V |
| Temperature fluctuation dependent on set value | 0.1...0.6 ± K p.2 ↗ | MKT115-400V |
| Cooling down time from 180°C to -70°C | 110 min p.2 ↗ | MKT115-400V |
| Rated voltage | 400 V p.2 ↗ | MKT115-400V, 50 Hz |
| Rated voltage | 480 V p.2 ↗ | MKT115-480V-C, 60 Hz |
| Power frequency | 50 Hz p.2 ↗ | MKT115-400V |
| Power frequency | 60 Hz p.2 ↗ | MKT115-480V-C |
| Nominal power | 5,5 kW p.2 ↗ | MKT115-400V |
| Unit fuse | 16,0 A p.2 ↗ | MKT115-400V |
| Phase (nominal voltage) | 3~/N/PE p.2 ↗ | MKT115-400V |
| Phase (nominal voltage) | 3~ p.2 ↗ | MKT115-480V-C |
| Interior volume | 115 L p.2 ↗ | MKT115-400V |
| Net weight of the unit (empty) | 305 kg p.2 ↗ | MKT115-400V |
| Load per rack | 30 kg p.2 ↗ | MKT115-400V |
| Permitted load | 60 kg p.2 ↗ | MKT115-400V |
| Wall clearance back | 300 mm p.2 ↗ | MKT115-400V |
| Wall clearance sidewise | 200 mm p.2 ↗ | MKT115-400V |
| Width net | 980 mm p.2 ↗ | MKT115-400V |
| Height net | 1,725 mm p.2 ↗ | MKT115-400V |
| Depth net | 865 mm p.2 ↗ | MKT115-400V |
| Interior width | 600 mm p.3 ↗ | MKT115-400V |
| Interior height | 480 mm p.3 ↗ | MKT115-400V |
| Interior depth | 400 mm p.3 ↗ | MKT115-400V |
Operating Limits
- Temperature range: -70...180 °C p.2 ↗
- Wall clearance back: 300 mm p.2 ↗
- Wall clearance sidewise: 200 mm p.2 ↗
- Permitted load: 60 kg p.2 ↗
- Load per rack: 30 kg p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-3 p.1 ↗ | MKT | Series: dynamic climate chamber for rapid temperature changes with extended low temperature range |
| 4-6 p.1 ↗ | 115 | Model size / interior volume 115 L |
| suffix p.1 ↗ | 400V | Standard variant, 400 V 3~/N/PE 50 Hz |
| suffix p.1 ↗ | 480V-C | Variant with voltage and frequency converter, 480 V 3~ 60 Hz |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| MKT115-400V p.1 ↗ | 9020-0385 | Standard, 400 V 3~/N/PE 50 Hz, 16,0 A | CEE 16 / 6 H plug 5-pin | |
| MKT115-480V-C p.1 ↗ | 9020-0363 | with voltage and frequency converter, 480 V 3~ 60 Hz, 16,0 A | CEE 16 / 6 H plug 5-pin |