Induztr
Resumen técnico Visor de documentos Modelos relacionados

Agilent Infinity III LC Series Brochure

Contenido

  1. Overview pp. 1-2
    Introduction to Infinity III LC series benefits and positioning
  2. p. 3
    Document contents listing
  3. Overview pp. 4-9
    Routine workflow benefits, reliability, and sustainability features
  4. Overview pp. 10-11
    Separation power and unknown identification capabilities
  5. Config. pp. 12-13
    1290 Infinity III LC system features and sample capacity
  6. Config. pp. 14-17
    1260 Infinity III and Prime LC routine analysis systems
  7. Config. pp. 18-19
    Compact walk-up multi-user solution
  8. Overview pp. 20-23
    Food, biopharma, and cannabis application performance
  9. Services pp. 24-25
    Software for faster analysis and easier LC/MS
  10. Overview pp. 26-27
    Rugged fast LC confidence and focus benefits
  11. Config. p. 28
    InfinityLab analytical instrument portfolio
  12. Ordering p. 29
    1290 Infinity III LC model selection table
  13. Ordering pp. 30-32
    System selection guides across LC models
  14. Services p. 31
    LC support and service offerings
  15. Config. pp. 33-34
    Special and tailored solution configurations
  16. Procedure pp. 35-36
    Method development solutions and further information
  17. p. 29 table, 15 rows
  18. p. 30 table, 13 rows
  19. p. 31 table, 8 rows
  20. p. 32 table, 11 rows
  21. p. 33 table, 11 rows

1290 Infinity III LC / 1260 Infinity III Prime LC / 1260 Infinity III LC / 1220 Infinity II LC

1290 Infinity III LC1260 Infinity III Prime LC1260 Infinity III LC1220 Infinity II LC
InfinityLab Assist✓✓✓—
InfinityLab Level Sensing✓✓✓—
Maximum Operating Pressure1300 bar800 bar400 or 600 bar600 bar
Flow (mL/minute)up to 5up to 5up to 5 or 10up to 10
Multisampler with Dual-Needle Injection✓✓✓—
Multisampler with InfinityLab Sample ID Reader✓✓✓—
Binary PumpHigh-Speed Pump*—✓Dual-Channel Gradient Pump
Quaternary PumpFlexible Pump**Flexible Pump**✓—
BlendAssist Software (available for all Flexible Pumps)✓✓——
Isocratic Pump——✓✓
ISET (Method Transfer)✓✓——
Multipurpose Valve (UHPLC)✓✓——
UV (VWD, DAD, MWD), ELSD, RID and FLD✓✓✓✓
Mass Spectrometry Detection✓✓✓✓
Lab Advisor Software for LC Maintenance✓✓✓✓

* High-Speed Pump: a high-end binary pump, ideal for fast gradients, often used with MS ** Flexible Pump: a high-end quaternary pump, ideal for routine labs

Configure your analytical LC system

InstrumentControlDescriptionProduct number
InfinityLab AssistInfinityLab Hub and Interface for status overview and dashboards for 1260 and 1290 Infinity II and III LCsG7178A
Solvent Preparation1260 Infinity II DegasserFour channels; up to 10 mL/min flow; 12 mL internal volume per channelG7122A
Solvent Delivery1290 Infinity III High-Speed Pump1300 bar up to 2 mL/min, ramping down to 800 bar at 5 mL/min; binary solvent mixing; integrated degassing unit; solvent selection valveG7120A
Solvent Delivery1290 Infinity III Flexible Pump1300 bar up to 2 mL/min, ramping down to 800 bar at 5 mL/min; quaternary solvent mixing; integrated degassing unitG7104A
Solvent Delivery1260 Infinity III Flexible Pump800 bar up to 5 mL/min; quaternary solvent mixing; integrated degassing unitG7104C
Solvent Delivery1260 Infinity III Binary Pump600 bar up to 5 mL/min; integrated degassing unit; optional solvent selection valveG7112B
Solvent Delivery1260 Infinity III Quaternary Pump600 bar up to 5 mL/min; 200 bar up to 10 mL/min; integrated degassing unitG7111B
Solvent Delivery1260 Infinity III Quaternary Pump VL400 bar up to 5 ml/min; 200 bar up to 10 ml/min; integrated degasser unitG7111A
Solvent Delivery1260 Infinity III Isocratic Pump600 bar up to 5 mL/min; 200 bar up to 10 mL/min; optional integrated degassing unit; solvent selection valveG7110B
Solvent Delivery1260 Infinity III SFC Binary PumpDelivers supercritical CO2 and modifiers at up to 600 bar and 5 mL/min; binary solvent mixing; integrated degassing unit and two-solvent selection valve for channel BG4782A
Valve Solutions1290 Infinity Flexible CubeFor enhanced injection modes and advanced valve-switching applications such as online SPEG4227A
Valve Solutions1290 Infinity III Valve DriveDrive unit for any InfinityLab Quick Change valve headG1170A
Valve SolutionsInfinityLab Quick Change ValvesAvailable in stainless steel for high-pressure and ultrahigh-pressure applications up to 1300 bar as well as with bio-inert materials in flow paths for biochromatographic applicationsList of product numbers*

* G4231A, G4231C, G4232C, G4232D, G4237A, G4234A, G4234C

LC Support Modules

ModuleDescriptionSpecificationsPart Number
1260 Infinity III SFC Control ModuleCompresses CO2 and houses backpressure regulator; uses liquefied (analytical grade) or gaseous CO2 (beverage grade); low dispersion nozzle for full flow transfer to MS or ELSDG4301A
1290 Infinity III Diode Array Detector± 0.6 μAU/cm noise (60 mm Max-Light cartridge cell) or ± 3 μAU/cm noise (10 mm Max-Light cell); 240 Hz; spectra; 8 signals; 1 to 8 nm slit; 190 to 640 nmG7117B
1290 Infinity III Diode Array Detector FS± 0.6 μAU/cm noise (60 mm Max-Light cartridge cell) or ± 3 μAU/cm noise (10 mm Max-Light cell); 120 Hz; spectra; 8 signals; fixed slit; 190 to 640 nmG7117A
1290 Infinity III Variable Wavelength Detector± 1.5 μAU noise; time-programmable, 240 Hz (single wavelength detection); 2.5 Hz (dual wavelength detection); 190 to 600 nmG7114B
1260 Infinity III Diode Array Detector HS± 0.6 μAU/cm noise (60 mm Max-Light cell) or ± 3 μAU/cm noise (10 mm Max-Light cell); 120 Hz; spectra; 8 signals; fixed slit; 190 to 640 nmG7117C
1260 Infinity III Diode Array Detector WR± 7 μAU/cm noise; 120 Hz; spectra; 8 signals; 190 to 950 nmG7115A
1260 Infinity III Multiple Wavelength Detector± 7 μAU/cm noise; 120 Hz; 8 signals; 190 to 950 nmG7165A
1260 Infinity III Variable Wavelength Detector± 2.5 μAU/cm noise; 120 Hz (single wavelength detection); 2.5 Hz (dual wavelength detection); 190 to 600 nmG7114A

Selection guide

Sample InjectionDescriptionPart number
1290 Infinity III Multisampler0 to 20 μL or 0 to 100 μL single-stroke injection at 1300 bar; up to 1500 μL with optional kits; sample capacity up to 432 vials and for up to 6144 samples; multiwash option for less than 9 ppm carryover; thermostatting available; dual-needle option for highest throughput and flexibilityG7167B
1290 Infinity III Vialsampler0.1 to 20 μL (40 optionally); up to 120 μL with multidraw mode at 1300 bar; sample capacity up to 132 x 2 mL vials; optional integrated column compartment for column heating up to 80 °C; thermostatting availableG7129B
1290 Infinity III Hybrid MultisamplerBoth classical flow-through injection and Agilent Feed Injection modes, with injection up to 1300 bar. Optional thermostatting availableG7137B
1260 Infinity III Multisampler0 to 100 μL single-stroke injection at 800 bar; up to 1800 μL with optional kits; sample capacity up to 432 vials and for up to 6144 samples; multiwash option for less than 9 ppm carryover; thermostatting available; dual-needle option for highest throughput and flexibilityG7167A
1260 Infinity III Hybrid MultisamplerBoth classical flow-through injection and Agilent Feed Injection modes injection, up to 800 bar. Optional thermostatting availableG7167C
1260 Infinity III Vialsampler0.1 to 100 μL injection from vials at up to 800 bar; up to 1500 μL with optional kits; optional integrated column compartment for column heating up to 80 °C; thermostatting availableG7129C
1260 Infinity III Vialsampler0.1 to 100 μL injection from vials at up to 600 bar; up to 1800 μL with optional kits; optional integrated column compartment for column heating up to 80 °C; thermostatting availableG7129A
1260 Infinity III Manual Injector5 μL to 20 mL injection loopsG1328C
Column
1290 Infinity III Multicolumn Thermostat20 degrees below ambient to 110 °C; up to four 30 cm columns and up to eight 10 cm columns; up to eight individual InfinityLab Quick Connect heat exchangers for standard-flow, high-flow, and ultralow dispersion; optional valve drive for InfinityLab Quick Change valve heads (up to 1300 bar and up to 8-column selection without replumbing)G7116B
1260 Infinity III Multicolumn Thermostat10 degrees below ambient to 85 °C; up to four 30 cm columns; up to four individual InfinityLab Quick Connect heat exchangers; optional valve drive for InfinityLab Quick Change valve heads (up to 800 bar and up to 4-column selection without replumbing)G7116A

Special Detection / Integrated LC Systems

ProductDescriptionPart Number
1290 Infinity III Evaporative Light Scattering DetectorFor subambient operation; flow range 0.2 to 5 mL/min; evaporator temperature 10 to 80 °C; nebulizer temperature 25 to 90 °CG7102A
1260 Infinity III Evaporative Light Scattering DetectorFor subambient operation; flow range 0.2 to 5 mL/min; evaporator temperature 25 to 120 °C; nebulizer temperature 25 to 90 °CG4260B
1290 Infinity III Fluorescence DetectorMultichannel UHPLC fluorescence detector with online spectra, 160 Hz, 2000 hr lamp, fast wavelength switching (< 250 ms) and low noise and high sensitivity (Raman vs. signal noise > 2500 S/N and Raman vs. dark noise > 30,000 S/N), 2 or 13 µL flow cellG7123B
1260 Infinity III Fluorescence Detector SpectraMultisignal fluorescence detector; online spectra; 4 signals; 148 Hz; 4000 h lamp; Raman (H2O) > 500 (noise reference measured at signal); Raman (H2O) > 3000 (noise reference measured at dark value)G7121B
1260 Infinity III Fluorescence DetectorOne signal wavelength, 74 Hz; 4000 h lamp; Raman (H2O) > 500 (noise reference measured at signal); Raman (H2O) > 3000 (noise reference measured at dark value)G7121A
1290 Infinity III Refractive Index Detector148 Hz; 1.00 to 1.75 RI range; ±600 x10-6 RIU measurement range; Noise < ±2.5 x10-9 RIU; < 1 h warm-up; 5 degrees above ambient up to 55 °CG7162B
1260 Infinity III Refractive Index Detector74 Hz; 1.00 to 1.75 RI range; ±600 x10-6 RIU measurement range; Noise < ±2.5 x10-9 RIU; < 1 h warm-up; 5 degrees above ambient up to 55 °CG7162A
1220 Infinity II Gradient LCDual-channel gradient pump, autosampler, column oven, and diode array detectorG4294B
1220 Infinity II Gradient LCDual-channel gradient pump, autosampler, column oven, and variable wavelength detectorG4290B
1220 Infinity II Gradient LCDual-channel gradient pump, manual injector, and variable wavelength detectorG4288B
1220 Infinity II Isocratic LCSingle solvent pump, manual injector, and variable wavelength detectorG4286B

Engineering Facts

13 facts · every claim linked to a page
Selection

The 1290 Infinity III LC is a UHPLC system intended for the most demanding separations, so it should be chosen when maximum resolution and speed are required.

Defines the application class where the 1290 platform is the correct choice versus routine HPLC.

Source
“The Agilent 1290 Infinity III LC is an ultrahigh-performance liquid chromatography (UHPLC) system offering rapid separation, high resolution, low dispersion, and unmatched sample capacity—for your most challenging application needs.”
Performance

The 1290 flow path supports 1300 bar at 2 mL/min and detector data rates up to 240 Hz, which sets the pressure and acquisition limits for method transfer.

Engineers must verify column and fitting pressure ratings and detector sampling rate before transferring UHPLC methods.

Source
“Specially designed components, such as needle seats, heat exchangers, column fittings, and flow cells, allow you to fully employ the power range of 1300 bar at 2 mL/minute. Data rates up to 240 Hz deliver uncompromised chromatographic resolution—even for your fastest separations.”
Selection

The 1290 Multisampler holds up to 16 microtiter plates (6,144 samples) or 432 vials and offers cooling, which drives the bench footprint and lab logistics.

Sample capacity and cooling requirements determine the autosampler configuration and bench space planning.

Source
“The 1290 Infinity III Multisampler accommodates up to 16 microtiter plates for a total capacity of 6,144 samples, or up to 432 vials. It also features an optional cooling system for sensitive samples.”
Performance

Dual-needle injection overlaps cycles to cut cycle time, and the multiwash option reduces carryover to below 9 ppm.

Carryover and cycle time specifications must be checked against method sensitivity and throughput targets.

Source
“Equipped with dual-needle injection, the 1290 Infinity III Multisampler enables you to reduce cycle times to mere seconds. And with the multiwash option, you can reduce carryover to less than 9 ppm for the standard single- or dual-needle option.”
Selection

The 1260 Infinity III LC is the routine HPLC workhorse covering analytical HPLC and entry-level UHPLC, so it fits standard QA/QC workloads.

Clarifies the intended use tier of the 1260 platform when matching a system to routine methods.

Source
“The Agilent 1260 Infinity III LC System provides robust high-performance liquid chromatography (HPLC) with a wide range of modules for both analytical HPLC and entry-level UHPLC.”
Operation

The 1260 quaternary pump reaches 600 bar, which limits the column particle size and flow rate combinations that can be used.

Pressure ceiling dictates which columns and methods are feasible on this pump.

Source
“The 1260 Infinity III Quaternary Pump delivers pressures of up to 600 bar, making it suitable for a wide range of routine applications.”
Selection

The 1260 Infinity III Prime LC extends operation to 800 bar and up to 5 mL/min, bridging routine HPLC and UHPLC capability.

The 800 bar / 5 mL/min envelope is the key differentiator when selecting the Prime LC over the standard 1260.

Source
“Ultimate performance for flow rates up to 5 mL/minute and pressures up to 800 bar”
Selection

The 1220 Infinity II pump delivers up to 10 mL/min and 600 bar, enabling smaller-particle columns for better resolution and faster runs.

Flow and pressure limits define the column choices and run times achievable on the compact system.

Source
“The 1220 Infinity II LC Pump ensures stable, virtually pulse-free solvent flow up to 10 mL/minute. A pressure range up to 600 bar even enables the use of columns with smaller particles for better resolution and faster run times.”
Installation

The 1220 Infinity II Mobile LC Solution uses a special mounting plate to absorb shock and vibration and secures columns and solvent containers for transport.

Mobile or field deployment requires this mechanical protection to avoid damage and ensure operator safety.

Source
“A special mounting plate absorbs shocks and vibration during transport or operation. Columns and solvent containers are held firmly in place, preventing instrument damage and maintaining operator safety.”
Operation

Agilent Feed Injection allows larger injection volumes without peak-shape loss even in 100% organic solvent, lowering detection limits.

Injection mode selection affects achievable sensitivity and must be matched to the sample solvent.

Source
“Compared to classical flow-through injection, Agilent Feed Injection allows significantly higher injection volumes without negative effects on peak shape, even when the sample is dissolved in 100% organic solvents.”
Cumplimiento

OpenLab CDS provides built-in technical controls for data integrity and regulatory compliance, which is required for regulated labs.

Data-integrity controls are a prerequisite when the system is used in a GxP or QA/QC environment.

Source
“It offers a powerful toolset for controlling Agilent InfinityLab LC instruments, complete with built-in technical controls to ensure data integrity and facilitate regulatory compliance.”
Maintenance

Altura HPLC columns use Ultra Inert technology to block active metal sites, giving faster equilibration, lower carryover and higher sensitivity for metal-sensitive analytes.

Column hardware inertness must be matched to metal-sensitive analytes to avoid adsorption and carryover.

Source
“Altura HPLC columns use Agilent Ultra Inert technology to block active metal sites, delivering an inert flow path with the durability and consistency of stainless steel.”
Maintenance

The CrossLab service guarantee replaces an instrument for free if it cannot be fixed under a service plan, which affects uptime risk planning.

Service-plan coverage and the replacement guarantee are relevant when assessing downtime risk and total cost.

Source
“If we cannot fix an instrument covered by a CrossLab service plan, regardless of manufacturer, our escalation process will resolve the issue up to and including replacing your instrument for free.”