Introduction to the 9500 ICP-QQQ and its key benefits
Overviewpp. 4-5
Built for confidence and simplicity in routine analysis
Qualitypp. 6-7
Performance data and results achievable by any lab
Overviewpp. 8-9
Effortless operation and focus on core lab work
Overviewp. 9
Summary of the Agilent 9500 ICP-QQQ advantages
p. 6table, 25 rows
p. 4table, 3 rows
Table 1. MSA calibration curves for the Ti digestion solution and procedural blank were used to determine 3σ DLs of blank samples (n = 5), BECs, and impurity metal concentrations in the original Ti sample.
The Dual-Cell System with Advanced Helium Mode and Air mode provides superior interference removal for complex matrices.
Interference removal capability is the primary selection criterion for trace analysis in complex matrices.
Source
“The Dual-Cell System (DCS) with Advanced Helium Mode (AHM) and Air mode provides superior interference removal”
Operation
AHM replaces multiple gas/tune modes with one mode, cutting acquisition time by more than 33% for routine analysis.
Fewer tune modes means simpler operation and higher sample throughput.
Source
“AHM eliminates the need for multiple gas modes and removes the wait times of method switching, typically >33% reduction in acquisition time for routine analysis.”
Safety
Air mode uses ambient air, so no O2 cylinders or gas cabinet infrastructure are required.
Avoids oxygen gas supply, gas cabinet, and associated safety approvals in the lab.
“Cell gas clean sensor to notify when replacement is due”
Operation
Power consumption is reduced 20% and exhaust flow 50%, lowering running costs and facility requirements.
Lower power and exhaust demands affect facility services and operating cost.
Source
“20% reduction in power consumption and 50% reduction in exhaust flow”
Performance
AHM gives about 20x higher sensitivity for low-mass elements and about 2x for mid-to-high masses versus conventional He mode.
Sensitivity gain determines detection limits for low-mass analytes.
Source
“AHM provides ~20× higher sensitivity for low-mass elements such as Li, Be and B, and ~2× for mid-to-high masses.”
Performance
Air mode achieves low BECs for P, S, As, and Se using oxygen from ambient air for mass-shift reactions.
Enables difficult elements without an added oxygen gas supply.
Source
“Air mode achieves low BECs for P, S, As, and Se which were previously only available to labs with an additional oxygen reaction gas supply.”
Performance
An optional m-lens enables sub-ppt impurity analysis in high-purity titanium with high-matrix-tolerant plasma.
Option selection depends on high-matrix, high-purity material applications.
Source
“With an optional m-lens, analysts can confidently analyze Ti matrix samples and verify material purity over extended measurement periods.”
Operation
Direct high-salinity seawater analysis is stable across 130+ analyses using on-line reverse dilution with AVS MS.
Confirms long-run stability for high-salinity samples with the right autosampler setup.
Source
“stability is maintained across 130+ analyses (EPA 6020)”
Operation
The 9500 includes UHMI aerosol dilution and an integrated grounded mixing block for on-line internal standard addition as standard.
Standard productivity tools reduce need for manual dilution and extra hardware.
Source
“The Agilent 9500 includes UHMI aerosol dilution to handle high matrix samples directly, integrated grounded mixing block for the on-line addition of internal standard”