Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 200 (soplador de canal lateral G-BH1), edición 07/2021. Abarca las variantes 2BH1200: 2BH1200-1AH06, 2BH1200-1AC03, 2BH1200-7AV04, 2BH1200-7AV05, además de las variantes de tensión/frecuencia seleccionadas mediante el código 2BH1200-..□ (H1, H6, H7, C3, C5, P1, P3, P5, P6, P7). Utilizable como bomba de vacío o compresor en funcionamiento continuo.
Technical Data
| Parameter |
Value |
Condición |
| Rated pressure (vacuum) |
-40 mbar
p.2 ↗ |
2BH1200-1AH06, 50 Hz |
| Max. differential pressure |
40 mbar
p.2 ↗ |
2BH1200-1AH06, 50 Hz |
| Rated pressure (vacuum) |
-55 mbar
p.2 ↗ |
2BH1200-1AH06, 60 Hz |
| Max. differential pressure |
55 mbar
p.2 ↗ |
2BH1200-1AH06, 60 Hz |
| Voltage |
200-240 / 345-415 Y V
p.2 ↗ |
2BH1200-1AH06, 50 Hz |
| Current |
1,38 / 0,8 Y A
p.2 ↗ |
2BH1200-1AH06, 50 Hz |
| Power |
0,25 kW
p.2 ↗ |
2BH1200-1AH06, 50 Hz |
| Voltage |
220-275 / 380-480 Y V
p.2 ↗ |
2BH1200-1AH06, 60 Hz |
| Current |
1,74 / 1,0 Y A
p.2 ↗ |
2BH1200-1AH06, 60 Hz |
| Power |
0,29 kW
p.2 ↗ |
2BH1200-1AH06, 60 Hz |
| Sound pressure level |
57 dB(A)
p.2 ↗ |
2BH1200-1AH06, 50 Hz |
| Sound pressure level |
61 dB(A)
p.2 ↗ |
2BH1200-1AH06, 60 Hz |
| Weight |
10 kg
p.2 ↗ |
2BH1200-1AH06 |
| Rated pressure (vacuum) |
-40 mbar
p.2 ↗ |
2BH1200-1AC03, 50 Hz |
| Max. differential pressure |
40 mbar
p.2 ↗ |
2BH1200-1AC03, 50 Hz |
| Voltage |
500 Y V
p.2 ↗ |
2BH1200-1AC03, 50 Hz |
| Current |
0,60 Y A
p.2 ↗ |
2BH1200-1AC03, 50 Hz |
| Power |
0,25 kW
p.2 ↗ |
2BH1200-1AC03, 50 Hz |
| Rated pressure (vacuum) |
-40 mbar
p.2 ↗ |
2BH1200-7AV04, 50 Hz |
| Voltage |
100 / 200 V
p.2 ↗ |
2BH1200-7AV04, 50 Hz |
| Current |
3,6 / 1,8 A
p.2 ↗ |
2BH1200-7AV04, 50 Hz |
| Power |
0,25 kW
p.2 ↗ |
2BH1200-7AV04, 50 Hz |
| Rated pressure (vacuum) |
-40 mbar
p.2 ↗ |
2BH1200-7AV05, 50 Hz |
| Voltage |
115 / 230 V
p.2 ↗ |
2BH1200-7AV05, 50 Hz |
| Current |
3,1 A
p.2 ↗ |
2BH1200-7AV05, 50 Hz |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C
p.1 ↗
- Performance curve reference air temperature: 15 °C
p.1 ↗
- Performance curve reference atmospheric pressure: 1013 mbar
p.1 ↗
- Performance curve tolerance: ± 10 %
p.1 ↗
- Frequency tolerance: +/- 2 % maximum
p.2 ↗
- Protection category: IP 55
p.1 ↗
Type Code Decoder
| Position |
Token |
Meaning |
| 1-7
p.2 ↗ |
2BH1200 |
Type/size designation: side channel blower 2BH1, size 200 |
| 10-11
p.2 ↗ |
AH / AC / AV |
Motor winding/voltage code (AH, AC, AV) |
| 12-13
p.2 ↗ |
06 / 03 / 04 / 05 |
Variant number within motor/voltage group |