Technical Data Sheet — G-BH1 2BH1400 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 400, soplador de canal lateral en configuración ATEX (G-BH1 N). Abarca las categorías ATEX 3GD, 3/2D y 3/2G como máquinas de tensión fija para 50 Hz y 60 Hz; 3/2G disponible solo como versiones de 50 Hz o 60 Hz. Código de pedido 2BH1…-1.□.□-Z con Z=M34, M71, M74/75.

Technical Data

Parameter Value Condición
Rated voltage 400 / 690 V p.2 ↗ 2BH1400, 50 Hz, Δ/Y
Rated current 2,25 / 1,30 A p.2 ↗ 2BH1400, 50 Hz, Δ/Y
Power 1,5 hp p.2 ↗ 2BH1400, 50 Hz
Max. vacuum -76 inch H2O p.2 ↗ 2BH1400, 50 Hz
Max. differential pressure 80 inch H2O p.2 ↗ 2BH1400, 50 Hz
Sound pressure level 61 dB(A) p.2 ↗ 2BH1400, 50 Hz
Rated voltage 460 V p.2 ↗ 2BH1400, 60 Hz, Δ
Rated current 2,25 A p.2 ↗ 2BH1400, 60 Hz, Δ
Power 1,7 hp p.2 ↗ 2BH1400, 60 Hz
Max. vacuum -72 inch H2O p.2 ↗ 2BH1400, 60 Hz
Max. differential pressure 68 inch H2O p.2 ↗ 2BH1400, 60 Hz
Sound pressure level 61 dB(A) p.2 ↗ 2BH1400, 60 Hz
Degree of protection IP55 p.2 ↗ 2BH1400
Efficiency class IE3 p.2 ↗ motor, thermal class F

Operating Limits

  • ATEX category availability: 3GD and 3/2D as fixed voltage machines for 50 and 60 Hz; 3/2G only 50 Hz or 60 Hz versions p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 59 °F p.1 ↗
  • Reference atmospheric pressure for performance curves: 29.92 inch Hg p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series G-BH1 side channel blower
5-7 p.2 ↗ 400 Size 400
field 1 p.2 ↗ 1 Version / generation
field 2 p.2 ↗ A ATEX category variant (A for 3/2G, D for 3/2D, G for 3GD)
field 3 p.2 ↗ D ATEX category 3/2D
field 3 p.2 ↗ G ATEX category 3GD
field 4 p.2 ↗ 1 Voltage code 230 Δ/400 Y (50 Hz) / 460 Y (60 Hz)
field 4 p.2 ↗ 6 Voltage code 400 Δ/690 Y (50 Hz) / 460 Δ (60 Hz)
field 4 p.2 ↗ 5 Voltage code 500 Δ (50 Hz) / 575 Δ (60 Hz)