Technical Data Sheet — G-BH1 2BH1400 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 400: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH1400. Variantes: 380 V delta a 87 Hz (VFD tipo B), 400 V delta a 87 Hz (VFD tipo A), 400 V delta a 87 Hz con 2,30 kW (VFD tipo B); funcionamiento a 50/60 Hz; VFD integrado 3~400 V -15%…480 V +10%, 50/60 Hz ±6%, IP55, UL 1450. Ejemplo de pedido 2BH1400-□□□□□-Z con Z=A11.

Technical Data

Parameter Value Condición
Rated motor voltage 380 V p.2 ↗ 2BH1400, 87 Hz, VFD type B
Rated motor current 5,1 A p.2 ↗ 2BH1400, 87 Hz, VFD type B
Motor power 2,30 kW p.2 ↗ 2BH1400, 87 Hz, VFD type B
Max. differential pressure, vacuum -200 mbar p.2 ↗ 2BH1400, 87 Hz, VFD type B
Max. differential pressure, pressure 180 mbar p.2 ↗ 2BH1400, 87 Hz, VFD type B
Sound pressure level 74 dB(A) p.2 ↗ 2BH1400, 87 Hz, VFD type B
Weight 28 kg p.2 ↗ 2BH1400, 87 Hz, VFD type B
Rated motor voltage 400 V p.2 ↗ 2BH1400, 87 Hz, VFD type A
Rated motor current 3,45 A p.2 ↗ 2BH1400, 87 Hz, VFD type A
Motor power 1,60 kW p.2 ↗ 2BH1400, 87 Hz, VFD type A
Max. differential pressure, vacuum -110 mbar p.2 ↗ 2BH1400, 87 Hz, VFD type A
Max. differential pressure, pressure 100 mbar p.2 ↗ 2BH1400, 87 Hz, VFD type A
Sound pressure level 74 dB(A) p.2 ↗ 2BH1400, 87 Hz, VFD type A
Weight 21 kg p.2 ↗ 2BH1400, 87 Hz, VFD type A
Rated motor voltage 400 V p.2 ↗ 2BH1400, 87 Hz, VFD type B
Rated motor current 4,6 A p.2 ↗ 2BH1400, 87 Hz, VFD type B
Motor power 2,30 kW p.2 ↗ 2BH1400, 87 Hz, VFD type B
Max. differential pressure, vacuum -200 mbar p.2 ↗ 2BH1400, 87 Hz, VFD type B
Max. differential pressure, pressure 180 mbar p.2 ↗ 2BH1400, 87 Hz, VFD type B
Sound pressure level 74 dB(A) p.2 ↗ 2BH1400, 87 Hz, VFD type B
Weight 23 kg p.2 ↗ 2BH1400, 87 Hz, VFD type B
Rated mains voltage 400 V p.2 ↗ Integrated VFD, 3~, -15%…480 V +10%
Mains frequency 50/60 Hz p.2 ↗ Integrated VFD, ±6%
Protection class IP55 p.2 ↗ Integrated VFD and motor
Insulation material class F p.2 ↗ Motor

Operating Limits

  • Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗
  • Integrated VFD mains voltage range: 400 V -15% … 480 V +10% p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH140 Type/size designation: side channel blower 2BH1, size 400
11-12 p.2 ↗ □□ Placeholder fields in ordering code 2BH1400-□□□□□-Z
13-14 p.2 ↗ □□ Placeholder fields in ordering code 2BH1400-□□□□□-Z

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1400-1A326 p.2 ↗ 2BH1400-1A326 380 V delta, 87 Hz, VFD type B Complete order number printed
2BH1400-1AK16 p.2 ↗ 2BH1400-1AK16 380 V delta, 87 Hz, VFD type B, 50/60 Hz Complete order number printed; footnote 3
2BH1400-1AK26 p.2 ↗ 2BH1400-1AK26 400 V delta, 87 Hz, VFD type A, 50/60 Hz Complete order number printed; footnote 3