Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1530 ATEX vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 530, soplador de canal lateral en configuración ATEX (G-BH1 N). Abarca las categorías ATEX 3GD, 3/2D y 3/2G, máquinas de tensión fija para 50 Hz y 60 Hz; 3/2G disponible solo como versiones de 50 Hz o 60 Hz.

Technical Data

Parameter Value Condición
Rated voltage 400 / 690 V p.2 ↗ 2BH1530, 50 Hz, delta/Y
Rated current 3.00 / 1.73 A p.2 ↗ 2BH1530, 50 Hz, delta/Y
Power 2.0 hp p.2 ↗ 2BH1530, 50 Hz
Max. differential pressure vacuum -56 inch H2O p.2 ↗ 2BH1530, 50 Hz
Max. differential pressure pressure 52 inch H2O p.2 ↗ 2BH1530, 50 Hz
Sound level 64 dB(A) p.2 ↗ 2BH1530, 50 Hz
Weight approx. 69 lbs p.2 ↗ 2BH1530, 50 Hz
Degree of protection IP55 p.2 ↗ 2BH1530
Rated voltage 460 V p.2 ↗ 2BH1530, 60 Hz, delta
Rated current 2.95 A p.2 ↗ 2BH1530, 60 Hz, delta
Power 2.3 hp p.2 ↗ 2BH1530, 60 Hz
Max. differential pressure vacuum -48 inch H2O p.2 ↗ 2BH1530, 60 Hz
Max. differential pressure pressure 44 inch H2O p.2 ↗ 2BH1530, 60 Hz
Sound level 64 dB(A) p.2 ↗ 2BH1530, 60 Hz
Weight approx. 69 lbs p.2 ↗ 2BH1530, 60 Hz
Rated voltage 400 / 690 V p.2 ↗ 2BH1530, 50 Hz, ATEX 3/2G, delta/Y
Rated current 4.2 / 2.4 A p.2 ↗ 2BH1530, 50 Hz, ATEX 3/2G, delta/Y
Power 3.0 hp p.2 ↗ 2BH1530, 50 Hz, ATEX 3/2G
Max. differential pressure vacuum -80 inch H2O p.2 ↗ 2BH1530, 50 Hz, ATEX 3/2G
Max. differential pressure pressure 92 inch H2O p.2 ↗ 2BH1530, 50 Hz, ATEX 3/2G
Sound level 69 dB(A) p.2 ↗ 2BH1530, 50 Hz, ATEX 3/2G
Weight approx. 69 lbs p.2 ↗ 2BH1530, 50 Hz, ATEX 3/2G
Rated voltage 460 V p.2 ↗ 2BH1530, 60 Hz, ATEX 3/2G, delta
Rated current 4.2 A p.2 ↗ 2BH1530, 60 Hz, ATEX 3/2G, delta
Power 3.4 hp p.2 ↗ 2BH1530, 60 Hz, ATEX 3/2G

Operating Limits

  • ATEX category availability: 3GD and 3/2D as fixed voltage machines for 50 and 60 Hz; 3/2G only 50 Hz or 60 Hz versions p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Reference air temperature for performance curves: 59 F p.1 ↗
  • Reference atmospheric pressure for performance curves: 29.92 inch Hg p.1 ↗
  • Motor thermal class: F p.2 ↗
  • Motor efficiency class: IE3 p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH1 Series G-BH1 side channel blower
5-7 p.2 ↗ 530 Size 530
field 1 p.2 ↗ D / G Voltage connection variant: D = delta, G = Y (star)
field 2 p.2 ↗ 1 / 5 / 6 Voltage code: 1 = 230Δ/400Y (50 Hz) or 460Y (60 Hz); 6 = 400Δ/690Y (50 Hz) or 460Δ (60 Hz); 5 = 500Δ (50 Hz) or 575Δ (60 Hz)