Technical Data Sheet — G-BH1 2BH1610 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 610: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH1 610, tamaños/variantes 2BH1610-1H336, -1H356, -1HK26, -1HK36, -1HK46, -1HK56; tipos de VFD F y G; 50/60 Hz, 3~ 400 V, IP55.

Technical Data

Parameter Value Condición
Rated motor voltage 380 V p.2 ↗ 2BH1610-1H336, 87 Hz
Rated motor current 14,9 A p.2 ↗ 2BH1610-1H336, 87 Hz
Motor power 7,5 kW p.2 ↗ 2BH1610-1H336, 87 Hz
Max. differential pressure, vacuum -250 mbar p.2 ↗ 2BH1610-1H336, 87 Hz
Max. differential pressure, pressure 200 mbar p.2 ↗ 2BH1610-1H336, 87 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH1610-1H336, 87 Hz
Weight 75 kg p.2 ↗ 2BH1610-1H336, 87 Hz
Rated motor voltage 380 V p.2 ↗ 2BH1610-1H356, 87 Hz
Rated motor current 27,4 A p.2 ↗ 2BH1610-1H356, 87 Hz
Motor power 14,0 kW p.2 ↗ 2BH1610-1H356, 87 Hz
Max. differential pressure, vacuum -460 mbar p.2 ↗ 2BH1610-1H356, 87 Hz
Max. differential pressure, pressure 400 mbar p.2 ↗ 2BH1610-1H356, 87 Hz
Sound pressure level 84 dB(A) p.2 ↗ 2BH1610-1H356, 87 Hz
Weight 107 kg p.2 ↗ 2BH1610-1H356, 87 Hz
Rated motor voltage 400 D V p.2 ↗ 2BH1610-1HK26, 87 Hz
Rated motor current 11,0 D A p.2 ↗ 2BH1610-1HK26, 87 Hz
Motor power 5,8 kW p.2 ↗ 2BH1610-1HK26, 87 Hz
Max. differential pressure, vacuum -80 mbar p.2 ↗ 2BH1610-1HK26, 87 Hz
Max. differential pressure, pressure 60 mbar p.2 ↗ 2BH1610-1HK26, 87 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH1610-1HK26, 87 Hz
Rated motor voltage 400 D V p.2 ↗ 2BH1610-1HK46, 87 Hz
Rated motor current 14,4 D A p.2 ↗ 2BH1610-1HK46, 87 Hz
Motor power 7,5 kW p.2 ↗ 2BH1610-1HK46, 87 Hz
Max. differential pressure, vacuum -250 mbar p.2 ↗ 2BH1610-1HK46, 87 Hz
Max. differential pressure, pressure 200 mbar p.2 ↗ 2BH1610-1HK46, 87 Hz

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
  • Rated voltage / frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗
  • Integrated VFD mains voltage range: 3~ 400 V -15% … 480 V +10% p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH1610 Type / size designation (side channel blower 2BH1 610)
7-8 p.2 ↗ 1H Motor / design variant field
9-10 p.2 ↗ 33, 35, K2, K3, K4, K5 Size / performance variant code (e.g. 33 = 7.5 kW, 35 = 14.0 kW, K2 = 5.8 kW, K3 = 7.5 kW, K4 = 10.2 kW, K5 = 14.0 kW)

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH1610-1H336 p.2 ↗ 2BH1610-1H336 F 87 Hz, 380 V, 7.5 kW VFD type F
2BH1610-1H356 p.2 ↗ 2BH1610-1H356 G 87 Hz, 380 V, 14.0 kW VFD type G
2BH1610-1HK26 p.2 ↗ 2BH1610-1HK26 E 87 Hz, 400 D, 5.8 kW VFD type E
2BH1610-1HK36 p.2 ↗ 2BH1610-1HK36 F 87 Hz, 400 D, 7.5 kW VFD type F
2BH1610-1HK46 p.2 ↗ 2BH1610-1HK46 G 87 Hz, 400 D, 10.2 kW VFD type G
2BH1610-1HK56 p.2 ↗ 2BH1610-1HK56 G 87 Hz, 400 D, 14.0 kW VFD type G