Technical Data Sheet — G-BH1 2BH1830 IE3 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BH1 830: soplador de canal lateral con convertidor de frecuencia integrado (VFD). Abarca las variantes de tipo 2BH1830 con números de pedido 2BH1830-1A316, 2BH1830-1A326, 2BH1830-1AK06, 2BH1830-1AK16, 2BH1830-1AK26, además de los tipos con VFD integrado 2FC4xxx-1□□00 y accesorios.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated motor voltage | 370 V p.2 ↗ | 2BH1830-1A316, 85 Hz |
| Rated motor current | 21,5 A p.2 ↗ | 2BH1830-1A316, 85 Hz |
| Rated motor power | 10,2 kW p.2 ↗ | 2BH1830-1A316, 85 Hz |
| Max. differential pressure, vacuum | -70 mbar p.2 ↗ | 2BH1830-1A316, 85 Hz |
| Max. differential pressure, pressure | 50 mbar p.2 ↗ | 2BH1830-1A316, 85 Hz |
| Sound pressure level | 85 dB(A) p.2 ↗ | 2BH1830-1A316, 85 Hz |
| Weight | 128 kg p.2 ↗ | 2BH1830-1A316 |
| Rated motor voltage | 380 V p.2 ↗ | 2BH1830-1A326, 85 Hz |
| Rated motor current | 27,4 A p.2 ↗ | 2BH1830-1A326, 85 Hz |
| Rated motor power | 14,0 kW p.2 ↗ | 2BH1830-1A326, 85 Hz |
| Max. differential pressure, vacuum | -230 mbar p.2 ↗ | 2BH1830-1A326, 85 Hz |
| Max. differential pressure, pressure | 170 mbar p.2 ↗ | 2BH1830-1A326, 85 Hz |
| Sound pressure level | 85 dB(A) p.2 ↗ | 2BH1830-1A326, 85 Hz |
| Weight | 159 kg p.2 ↗ | 2BH1830-1A326 |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1830-1AK06, 85 Hz |
| Rated motor current | 14,4 A p.2 ↗ | 2BH1830-1AK06, 85 Hz |
| Rated motor power | 7,5 kW p.2 ↗ | 2BH1830-1AK06, 85 Hz |
| Max. differential pressure, vacuum | -250 mbar p.2 ↗ | 2BH1830-1AK06, 50 Hz |
| Max. differential pressure, pressure | 230 mbar p.2 ↗ | 2BH1830-1AK06, 50 Hz |
| Sound pressure level | 78 dB(A) p.2 ↗ | 2BH1830-1AK06, 50 Hz |
| Weight | 117 kg p.2 ↗ | 2BH1830-1AK06 |
| Rated motor voltage | 400 V p.2 ↗ | 2BH1830-1AK16, 85 Hz |
| Rated motor current | 20,0 A p.2 ↗ | 2BH1830-1AK16, 85 Hz |
| Rated motor power | 10,2 kW p.2 ↗ | 2BH1830-1AK16, 85 Hz |
| Weight | 127 kg p.2 ↗ | 2BH1830-1AK16 |
Operating Limits
- Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
- Min. mains voltage for frequency converter: 380 V p.1 ↗
- Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
- Min. pulse frequency for performance curves: 4 kHz p.1 ↗
- Protection class: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BH1830 | Type designation: side channel blower 2BH1, size 830 |
| VFD field 1 p.2 ↗ | A-K | VFD size letter (A, B, C, D, E, F, G, H, J, K) for 2FC4xxx-1□□00 |
| VFD field 2 p.2 ↗ | □□ | Placeholder for VFD voltage / option code |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Aplica a | Note |
|---|---|---|---|---|
| 2BH1830-1A316 p.2 ↗ | 2BH1830-1A316 | G | 85 Hz, 370 V | VFD type G |
| 2BH1830-1A326 p.2 ↗ | 2BH1830-1A326 | G | 85 Hz, 380 V | VFD type G |
| 2BH1830-1AK06 p.2 ↗ | 2BH1830-1AK06 | F | 85 Hz, 400 V | VFD type F |
| 2BH1830-1AK16 p.2 ↗ | 2BH1830-1AK16 | G | 85 Hz, 400 V | VFD type G |
| 2BH1830-1AK26 p.2 ↗ | 2BH1830-1AK26 | G | 85 Hz, 400 V | VFD type G |
Modelos relacionados
Elmo Rietschle 2BH1009
Elmo Rietschle 2BH1014
Elmo Rietschle 2BH1015
Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1035
Elmo Rietschle 2BH1100
Elmo Rietschle 2BH1200
Elmo Rietschle 2BH1300
Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1330
Elmo Rietschle 2BH1400
Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1430
Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1500
Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1530
Elmo Rietschle 2BH1590
Elmo Rietschle 2BH1600
Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1630
Elmo Rietschle 2BH1640
Elmo Rietschle 2BH1690
Elmo Rietschle 2BH1800
Elmo Rietschle 2BH1810
Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1900
Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1930
Elmo Rietschle 2BH1940
Elmo Rietschle 2BH1943