Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 2BH1940 IE3 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH1 940: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH1 940, 3~ 50/60 Hz, IP55, clase de aislamiento F, UL 1450 / CAN/CSA C22.2 No. 68-09 (E225239). Abarca el funcionamiento a 50 Hz y 60 Hz y los tipos de VFD A–K (2FC4xxx).

Technical Data

Parameter Value Condición
Rated motor voltage 330 D V p.2 ↗ 2BH1 940, 72 Hz, VFD operation
Rated motor current 65,3 D A p.2 ↗ 2BH1 940, 72 Hz, VFD operation
Rated motor power 29,4 kW p.2 ↗ 2BH1 940, 72 Hz, VFD operation
Max. differential pressure, vacuum -100 mbar p.2 ↗ 2BH1 940, 72 Hz, VFD operation
Max. differential pressure, pressure 80 mbar p.2 ↗ 2BH1 940, 72 Hz, VFD operation
Sound pressure level 82 dB(A) p.2 ↗ 2BH1 940, 72 Hz, VFD operation
Max. differential pressure, vacuum -220 mbar p.2 ↗ 2BH1 940, 50 Hz
Max. differential pressure, pressure 200 mbar p.2 ↗ 2BH1 940, 50 Hz
Sound pressure level 73 dB(A) p.2 ↗ 2BH1 940, 50 Hz
Weight 80/81 kg p.2 ↗ 2BH1 940, 50 Hz
Max. differential pressure, vacuum -160 mbar p.2 ↗ 2BH1 940, 60 Hz
Max. differential pressure, pressure 150 mbar p.2 ↗ 2BH1 940, 60 Hz
Sound pressure level 77 dB(A) p.2 ↗ 2BH1 940, 60 Hz
Max. differential pressure, vacuum -270 mbar p.2 ↗ 2BH1 940, 50 Hz, variant 2
Max. differential pressure, pressure 300 mbar p.2 ↗ 2BH1 940, 50 Hz, variant 2
Max. differential pressure, vacuum -300 mbar p.2 ↗ 2BH1 940, 50 Hz, variant 2
Max. differential pressure, pressure 300 mbar p.2 ↗ 2BH1 940, 50 Hz, variant 2
Max. differential pressure, vacuum -280 mbar p.2 ↗ 2BH1 940, 60 Hz, variant 2
Max. differential pressure, pressure 250 mbar p.2 ↗ 2BH1 940, 60 Hz, variant 2
Sound pressure level 77 dB(A) p.2 ↗ 2BH1 940, 60 Hz, variant 2
Rated motor voltage 330 D V p.2 ↗ 2BH1 940, 72 Hz, variant 2
Rated motor current 79,0 D A p.2 ↗ 2BH1 940, 72 Hz, variant 2
Rated motor power 35,0 kW p.2 ↗ 2BH1 940, 72 Hz, variant 2
Max. differential pressure, vacuum -200 mbar p.2 ↗ 2BH1 940, 72 Hz, variant 2
Max. differential pressure, pressure 150 mbar p.2 ↗ 2BH1 940, 72 Hz, variant 2

Operating Limits

  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Minimum frequency converter pulse frequency: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗
  • Protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH194 Type/size designation: side channel blower 2BH1, size 940
7-8 p.2 ↗ -1 Design variant / generation
9-10 p.2 ↗ BK Motor/connection variant code
11-12 p.2 ↗ 36 / 46 Variant suffix (36 or 46) selecting the performance/motor version
Z field p.2 ↗ A11 Ordering example substitution: 2BH1940-□□□□□-Z with Z=A11
VFD type field p.2 ↗ A–K Frequency converter type letter (A=2FC4152-1□□□00 … K=2FC4223-1□□□00)