Technical Data

Parameter Value Condición
Rated motor voltage 400 V p.2 ↗ 2BH7620-0N341-2, 100 Hz
Rated motor current 16,2 A p.2 ↗ 2BH7620-0N341-2, 100 Hz
Rated motor power 8,8 kW p.2 ↗ 2BH7620-0N341-2, 100 Hz
Max. differential pressure vacuum -450 mbar p.2 ↗ 2BH7620-0N341-2, 100 Hz
Max. differential pressure pressure 350 mbar p.2 ↗ 2BH7620-0N341-2, 100 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH7620-0N341-2, 100 Hz
Weight approx. 77 kg p.2 ↗ 2BH7620-0N341-2
Rated motor voltage 400 V p.2 ↗ 2BH7620-0N371-2, 100 Hz
Rated motor current 22,0 A p.2 ↗ 2BH7620-0N371-2, 100 Hz
Rated motor power 12,1 kW p.2 ↗ 2BH7620-0N371-2, 100 Hz
Max. differential pressure vacuum -490 mbar p.2 ↗ 2BH7620-0N371-2, 100 Hz
Max. differential pressure pressure 580 mbar p.2 ↗ 2BH7620-0N371-2, 100 Hz
Sound pressure level 85 dB(A) p.2 ↗ 2BH7620-0N371-2, 100 Hz
Weight approx. 95 kg p.2 ↗ 2BH7620-0N371-2
Rated motor voltage 380 V p.2 ↗ 2BH7620-0N346-2, 87 Hz
Rated motor current 14,9 A p.2 ↗ 2BH7620-0N346-2, 87 Hz
Rated motor power 7,5 kW p.2 ↗ 2BH7620-0N346-2, 87 Hz
Max. differential pressure vacuum -590 mbar p.2 ↗ 2BH7620-0N346-2, 87 Hz
Max. differential pressure pressure 450 mbar p.2 ↗ 2BH7620-0N346-2, 87 Hz
Sound pressure level 79 dB(A) p.2 ↗ 2BH7620-0N346-2, 87 Hz
Weight approx. 75 kg p.2 ↗ 2BH7620-0N346-2
Rated motor voltage 380 V p.2 ↗ 2BH7620-0N376-2, 85 Hz
Rated motor current 20,3 A p.2 ↗ 2BH7620-0N376-2, 85 Hz
Rated motor power 10,2 kW p.2 ↗ 2BH7620-0N376-2, 85 Hz
Max. differential pressure vacuum -590 mbar p.2 ↗ 2BH7620-0N376-2, 85 Hz

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗
  • Minimum mains voltage for frequency converters: 380 V p.1 ↗
  • Protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH7 Series G-BH7 side channel blower
5-8 p.2 ↗ 620-0N Size / basic type 2BH7 620-0N
9-11 p.2 ↗ 341 / 371 / 346 / 376 / K26 / K46 / K76 Motor / performance variant code
External VFD field 1 p.2 ↗ A / B / C / D / E / F / G / H / J / K External frequency converter type
External VFD field 2 p.2 ↗ □ □00 Placeholder for VFD option code

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH7620-0N341-2 p.2 ↗ 2BH7620-0N341-2 F 100 Hz, 400 V, VFD type F Integrated VFD
2BH7620-0N371-2 p.2 ↗ 2BH7620-0N371-2 G 100 Hz, 400 V, VFD type G Integrated VFD
2BH7620-0N346-2 p.2 ↗ 2BH7620-0N346-2 F 87 Hz, 380 V, VFD type F Integrated VFD
2BH7620-0N376-2 p.2 ↗ 2BH7620-0N376-2 G 85 Hz, 380 V, VFD type G Integrated VFD
2BH7620-0NK26-2 p.2 ↗ 2BH7620-0NK26-2 E 87 Hz, 400 V, VFD type E Integrated VFD
2BH7620-0NK46-2 p.2 ↗ 2BH7620-0NK46-2 F 87 Hz, 400 V, VFD type F Integrated VFD
2BH7620-0NK76-2 p.2 ↗ 2BH7620-0NK76-2 G 85 Hz, 400 V, VFD type G Integrated VFD