Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — 2BH9230 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos 2BH92300: soplador de canal lateral con convertidor de frecuencia integrado (VFD), tipo 2BH92300. Abarca funcionamiento a 50 Hz y 60 Hz, funcionamiento en vacío y en presión, descarga a la derecha (estándar) y descarga a la izquierda (opcional), y tipos de VFD A–K.

Technical Data

Parameter Value Condición
Frequency 60 Hz p.2 ↗ 2BH92300, 60 Hz
Rated voltage 370 V p.2 ↗ 2BH92300, 60 Hz
Current 35,5 A p.2 ↗ 2BH92300, 60 Hz
Power 18,5 kW p.2 ↗ 2BH92300, 60 Hz
Max. differential pressure, vacuum -130 mbar p.2 ↗ 2BH92300, 60 Hz
Max. differential pressure, pressure 110 mbar p.2 ↗ 2BH92300, 60 Hz
Sound pressure level 81 dB(A) p.2 ↗ 2BH92300, 60 Hz
Weight 166 kg p.2 ↗ 2BH92300, 60 Hz
Frequency 60 Hz p.2 ↗ 2BH92300, 60 Hz, VFD type J
Rated voltage 370 V p.2 ↗ 2BH92300, 60 Hz, VFD type J
Current 24,5 A p.2 ↗ 2BH92300, 60 Hz, VFD type J
Max. differential pressure, vacuum -190 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type J
Max. differential pressure, pressure 180 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type J
Weight 178 kg p.2 ↗ 2BH92300, 60 Hz, VFD type J
Frequency 50 Hz p.2 ↗ 2BH92300, 50 Hz
Max. differential pressure, vacuum -190 mbar p.2 ↗ 2BH92300, 50 Hz
Max. differential pressure, pressure 170 mbar p.2 ↗ 2BH92300, 50 Hz
Weight 146 kg p.2 ↗ 2BH92300, 50 Hz
Frequency 60 Hz p.2 ↗ 2BH92300, 60 Hz, VFD type A
Rated voltage 265 ∆ V p.2 ↗ 2BH92300, 60 Hz, VFD type A
Current 55,5 ∆ A p.2 ↗ 2BH92300, 60 Hz, VFD type A
Power 19,9 kW p.2 ↗ 2BH92300, 60 Hz, VFD type A
Max. differential pressure, vacuum -150 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type A
Max. differential pressure, pressure 130 mbar p.2 ↗ 2BH92300, 60 Hz, VFD type A
Weight 148 kg p.2 ↗ 2BH92300, 50 Hz, VFD type A

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve reference air temperature: 15 °C p.1 ↗
  • Performance curve reference atmospheric pressure: 1013 mbar p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Minimum pulse frequency of frequency converter: 4 kHz p.1 ↗
  • Rated voltage/frequency set point: 345 V / 87 Hz p.1 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ 2BH92300 Blower type / size designation
field 1 p.2 ↗ 1 Version / generation field
field 2 p.2 ↗ AA Motor / connection variant field
field 3 p.2 ↗ Pxx Placeholder for VFD type (A–K)
field 4 p.2 ↗ AA Discharge direction: AA = discharge right (standard); optional discharge left variant printed as 2BH9 2300-5AAPxx-AA
field 5 p.2 ↗ Q2 / R2 / KQ6 / KR6 Variant code of the selection table row
field 6 p.2 ↗ BA Suffix variant code

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
2BH92300-1AA3Q2-BA p.2 ↗ 2BH92300-1AA3Q2-BA J 60 Hz, VFD type J
2BH92300-1AA3R2-BA p.2 ↗ 2BH92300-1AA3R2-BA 60 Hz
2BH92300-1AAKQ6-BA p.2 ↗ 2BH92300-1AAKQ6-BA 50 Hz footnote 3)
2BH92300-1AAKR6-BA p.2 ↗ 2BH92300-1AAKR6-BA 50 Hz footnote 3)