Technical Data Sheet — L-BV7 2BV7071 IE3 compressor (EN)
Technical Reference Summary
Covered Models & Document Scope
Familia de compresores de anillo líquido L-BV7, hoja de datos para la gama de modelos 2BV7 071. Abarca 2BV7071-2 y 2BV7071-3 en fundición (estándar) y acero inoxidable (carcasa/placa de conexión de acero CrNi, impulsor de bronce, linterna de fundición). Variantes de tensión K08-1B, K08-6B, Q08-7B; 50 Hz y 60 Hz; eficiencia IE3 y NP; categoría ATEX 2G disponible.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Rated voltage | 190-210 V p.2 ↗ | 2BV7071-2, 50 Hz, delta |
| Rated current | 23,5 A p.2 ↗ | 2BV7071-2, 50 Hz, delta |
| Motor power | 6,3 kW p.2 ↗ | 2BV7071-2, 50 Hz |
| Service factor | 1,00 p.2 ↗ | 2BV7071-2, 50 Hz |
| Efficiency class | IE3 p.2 ↗ | 2BV7071-2, 50 Hz |
| Quantity of operating liquid | 0,45 m3/h p.2 ↗ | 2BV7071-2, 50 Hz |
| Sound pressure level | 72 dB(A) p.2 ↗ | 2BV7071-2, 50 Hz |
| Weight | 55 kg p.2 ↗ | 2BV7071-2, 50 Hz |
| Rated voltage | 190-210 YY / 380-420 Y V p.2 ↗ | 2BV7071-2, 50 Hz, YY/Y |
| Rated current | 27,6 YY / 13,8 Y A p.2 ↗ | 2BV7071-2, 50 Hz, YY/Y |
| Motor power | 7,3 kW p.2 ↗ | 2BV7071-2, 50 Hz, YY/Y |
| Quantity of operating liquid | 0,54 m3/h p.2 ↗ | 2BV7071-2, 50 Hz, YY/Y |
| Sound pressure level | 78 dB(A) p.2 ↗ | 2BV7071-2, 50 Hz, YY/Y |
| Rated voltage | 220-240 / 380-420 V p.2 ↗ | 2BV7071-2, 50 Hz, delta/Y |
| Rated current | 20,4 / 11,8 A p.2 ↗ | 2BV7071-2, 50 Hz, delta/Y |
| Motor power | 6,3 kW p.2 ↗ | 2BV7071-2, 50 Hz, delta/Y |
| Rated voltage | 500 V p.2 ↗ | 2BV7071-2, 50 Hz, Y |
| Rated current | 9,5 A p.2 ↗ | 2BV7071-2, 50 Hz, Y |
| Motor power | 6,3 kW p.2 ↗ | 2BV7071-2, 50 Hz, Y |
| Rated voltage | 575 V p.2 ↗ | 2BV7071-2, 60 Hz, Y |
| Rated current | 9,6 A p.2 ↗ | 2BV7071-2, 60 Hz, Y |
| Motor power | 7,3 kW p.2 ↗ | 2BV7071-2, 60 Hz, Y |
| Motor power | 8,6 kW p.2 ↗ | 2BV7071-3, 50 Hz |
| Weight | 68 kg p.2 ↗ | 2BV7071-3, 50 Hz |
| Protection rating | IP55 p.2 ↗ | all variants |
Operating Limits
- Protection rating: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
- Intake temperature for characteristic curves: 20 °C p.1 ↗
- Operating liquid temperature for characteristic curves: 15 °C p.1 ↗
- Characteristic curve tolerance: ± 10 % p.1 ↗
- Sound pressure level tolerance: ±3 dB(A) p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-6 p.2 ↗ | 2BV7071 | Model range and size (2BV7 071) |
| 11-13 p.2 ↗ | 08-1B / 08-6B / 08-7B | Voltage and frequency variant: 1B = 50 Hz 190-210 VΔ / 380-420 VY; 6B = 50/60 Hz 220-240 VΔ / 380-420 VY; 7B = 50/60 Hz 380-420 VΔ / 660-725 VY |
| field K p.2 ↗ | K | Cast iron casing/port plate, bronze impeller, cast iron lantern |
| field Q p.2 ↗ | Q | CrNi steel casing and port plate, bronze impeller, cast iron lantern |