Technical Data Sheet — L-BV7 2BV7071 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Hoja de datos 2BV7 071: bomba de vacío de anillo líquido con eyector, gama de modelos L-BV7, edición 09/2013. Motores estándar para rangos de tensión de entrada de 50 y 60 Hz, categoría de protección IP55, aprobados para UL y CSA.
Technical Data
| Parameter | Value | Condición |
|---|---|---|
| Ultimate inlet pressure | 33 mbar abs. p.1 ↗ | 2BV7 071, 97 % vacuum |
| Cavitation-free operation minimum inlet pressure | 80 mbar abs. p.1 ↗ | 2BV7 071, without connected cavitation protection |
| Operating liquid temperature for characteristic curves | 15 °C p.1 ↗ | water as operating liquid, suction pressure 1013 mbar abs. |
| Intake temperature for characteristic curves | 20 °C p.1 ↗ | evacuation of 100 % saturated air |
| Characteristic curve tolerance | ± 10 % p.1 ↗ | |
| Protection rating | IP55 p.1 ↗ | standard motor |
| Mains frequency | 50 and 60 Hz p.1 ↗ | standard motor input voltage ranges |
Operating Limits
- Minimum inlet pressure (ultimate vacuum): 33 mbar abs. (97 % vacuum) p.1 ↗
- Minimum inlet pressure for cavitation-free operation without connected cavitation protection: 80 mbar abs. p.1 ↗
- Protection category: IP55 p.1 ↗