Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 BH1009-6 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos BH1009-6 (2BH1330), soplador de canal lateral con motor monofásico, 50/60 Hz, IP55, clase de aislamiento F, aprobado UL/CSA; códigos de pedido BH1009-6AAA-BV5-BA0 y BH1009-6AAA-BV4-BA0, además de las variantes de tensión del motor V4 (100/200 V) y V5 (115/230 V).

Technical Data

Parameter Value Condición
Frequency 50/60 Hz p.2 ↗ BH1009-6
Voltage 115 / 230 V p.2 ↗ BH1009-6AAA-BV5-BA0, 50 Hz
Current 8,5 / 4,2 A p.2 ↗ BH1009-6AAA-BV5-BA0, 50 Hz
Power 0,5 hp p.2 ↗ BH1009-6AAA-BV5-BA0, 50 Hz
Max. differential pressure, vacuum -44 inch H2O p.2 ↗ BH1009-6AAA-BV5-BA0, 50 Hz
Max. differential pressure, pressure 40 inch H2O p.2 ↗ BH1009-6AAA-BV5-BA0, 50 Hz
Sound pressure level 58 dB(A) p.2 ↗ BH1009-6AAA-BV5-BA0, 50 Hz
Weight approx. 29 lbs p.2 ↗ BH1009-6AAA-BV5-BA0, 50 Hz
Voltage 115 / 230 V p.2 ↗ BH1009-6AAA-BV5-BA0, 60 Hz
Current 7,0 / 3,4 A p.2 ↗ BH1009-6AAA-BV5-BA0, 60 Hz
Power 0,6 hp p.2 ↗ BH1009-6AAA-BV5-BA0, 60 Hz
Max. differential pressure, vacuum -44 inch H2O p.2 ↗ BH1009-6AAA-BV5-BA0, 60 Hz
Max. differential pressure, pressure 40 inch H2O p.2 ↗ BH1009-6AAA-BV5-BA0, 60 Hz
Sound pressure level 60 dB(A) p.2 ↗ BH1009-6AAA-BV5-BA0, 60 Hz
Weight approx. 29 lbs p.2 ↗ BH1009-6AAA-BV5-BA0, 60 Hz
Protection category IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors
Performance tolerance ± 10 % p.1 ↗ performance curves
Frequency tolerance +/- 2 % p.2 ↗ maximum
Voltage tolerance, single phase +/- 5 % p.2 ↗ single phase machines

Operating Limits

  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Max. differential pressure, vacuum: -44 inch H2O p.2 ↗
  • Max. differential pressure, pressure: 40 inch H2O p.2 ↗
  • Frequency tolerance: +/- 2 % p.2 ↗
  • Voltage tolerance, single phase: +/- 5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ BH1009-6 Type / size designation (2BH1330)
9-11 p.2 ↗ AAA Design variant field
13-15 p.2 ↗ BV5 Motor voltage variant: V5 = 115/230 V, 50/60 Hz
13-15 p.2 ↗ BV4 Motor voltage variant: V4 = 100/200 V, 50/60 Hz
17-19 p.2 ↗ BA0 Design variant field

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
BH1009-6AAA-BV5-BA0 p.2 ↗ BH1009-6AAA-BV5-BA0 V5 1~ 50/60 Hz, 115/230 V, IP55, insulation class F, UL, with capacitor for continuous operation 50 Hz: 8,5/4,2 A, 0,5 hp; 60 Hz: 7,0/3,4 A, 0,6 hp
BH1009-6AAA-BV4-BA0 p.2 ↗ BH1009-6AAA-BV4-BA0 V4 1~ 50/60 Hz, 100/200 V, IP55, insulation class F, UL, with capacitor for continuous operation Electrical data not available (#NV)