Technical Data Sheet — G-BH1 BH1015-6 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Hoja de datos BH1015-6 (2BH1430), soplador de canal lateral con motor monofásico, 50/60 Hz, IP55, clase de aislamiento F, aprobado UL/CSA. Códigos de pedido BH1015-6AAA-FV5-BA0 y BH1015-6AAA-FV4-BA0; variantes de tensión del motor V4 (100/200 V) y V5 (115/230 V).

Technical Data

Parameter Value Condición
Rated voltage 115 / 230 V p.2 ↗ BH1015-6, 50 Hz
Rated current 17,0 / 8,0 A p.2 ↗ BH1015-6, 50 Hz
Power 1,5 hp p.2 ↗ BH1015-6, 50 Hz
Max. differential pressure vacuum -60 inch H2O p.2 ↗ BH1015-6, 50 Hz
Max. differential pressure pressure 56 inch H2O p.2 ↗ BH1015-6, 50 Hz
Sound pressure level 61 dB(A) p.2 ↗ BH1015-6, 50 Hz
Weight approx. 49 lbs p.2 ↗ BH1015-6, 50 Hz
Rated voltage 115 / 230 V p.2 ↗ BH1015-6, 60 Hz
Rated current 16,0 / 8,0 A p.2 ↗ BH1015-6, 60 Hz
Power 1,7 hp p.2 ↗ BH1015-6, 60 Hz
Max. differential pressure vacuum -56 inch H2O p.2 ↗ BH1015-6, 60 Hz
Max. differential pressure pressure 52 inch H2O p.2 ↗ BH1015-6, 60 Hz
Sound pressure level 64 dB(A) p.2 ↗ BH1015-6, 60 Hz
Weight approx. 49 lbs p.2 ↗ BH1015-6, 60 Hz
Protection category IP55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors

Operating Limits

  • Protection category: IP55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Frequency tolerance: ±2 % maximum p.2 ↗
  • Single-phase voltage tolerance: ±5 % p.2 ↗

Type Code Decoder

Position Token Meaning
1-9 p.2 ↗ BH1015-6 Type / size designation (2BH1430)
10-12 p.2 ↗ AAA Basic design variant
14-16 p.2 ↗ FV5 Motor voltage variant: FV5 = 115/230 V (50/60 Hz); FV4 = 100/200 V (50/60 Hz)
18-20 p.2 ↗ BA0 Configuration suffix

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
BH1015-6AAA-FV5-BA0 p.2 ↗ BH1015-6AAA-FV5-BA0 V5 50/60 Hz, 115/230 V 1~ 50/60 Hz, IP55, insulation class F, UL, capacitor for continuous operation
BH1015-6AAA-FV4-BA0 p.2 ↗ BH1015-6AAA-FV4-BA0 V4 50/60 Hz, 100/200 V 1~ 50/60 Hz, IP55, insulation class F, UL, capacitor for continuous operation