Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — G-BH1 BH1023-1 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Soplador de canal lateral G-BH1, hoja de datos BH1023-1 (2BH1500), motor monofásico; variantes de 50 Hz y 60 Hz; variantes de tensión 115/230 V y 100/200 V (V4); código de pedido BH1023-1...-□□□

Technical Data

Parameter Value Condición
Rated pressure -76 inch H2O p.2 ↗ BH1023-1, 50 Hz
Max. differential pressure 80 inch H2O p.2 ↗ BH1023-1, 50 Hz
Voltage 115 / 230 V p.2 ↗ BH1023-1, 50 Hz
Current 19,0 / 9,5 A p.2 ↗ BH1023-1, 50 Hz
Power 2,0 hp p.2 ↗ BH1023-1, 50 Hz
Sound pressure level 61 dB(A) p.2 ↗ BH1023-1, 50 Hz
Weight 68 lbs p.2 ↗ BH1023-1, 50 Hz
Rated pressure -72 inch H2O p.2 ↗ BH1023-1, 60 Hz
Max. differential pressure 72 inch H2O p.2 ↗ BH1023-1, 60 Hz
Voltage 115 / 230 V p.2 ↗ BH1023-1, 60 Hz
Current 20,0 / 10,0 A p.2 ↗ BH1023-1, 60 Hz
Power 2,3 hp p.2 ↗ BH1023-1, 60 Hz
Sound pressure level 64 dB(A) p.2 ↗ BH1023-1, 60 Hz
Weight 68 lbs p.2 ↗ BH1023-1, 60 Hz
Protection category IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors
Performance tolerance ± 10 % p.1 ↗ performance curves
Reference air temperature 59 F p.1 ↗ performance curves
Reference atmospheric pressure 29.92 inch Hg p.1 ↗ performance curves

Operating Limits

  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-8 p.2 ↗ BH1023-1 Type/size designation (2BH1500)
field 1 p.2 ↗ □□□ Motor voltage variant: V4 = 100/200 V, 50/60 Hz; blank = 115/230 V, 50/60 Hz