Induztr
Resumen técnico Visor de documentos Modelos relacionados

Technical Data Sheet — IE3 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Bombas de vacío rotativas de paletas secas de la serie V-VTR, modelos V-VTR 100 y V-VTR 140, con motores IE3, variantes de 50 Hz y 60 Hz, 3~ 230/400 V (50 Hz) o 220/380 V (60 Hz), IP 55, clase de aislamiento F

Technical Data

Parameter Value Condición
Suction capacity 100 m³/h p.2 ↗ V-VTR 100, 50 Hz
Suction capacity 130 m³/h p.2 ↗ V-VTR 140, 50 Hz
Suction capacity 120 m³/h p.2 ↗ V-VTR 100, 60 Hz
Suction capacity 155 m³/h p.2 ↗ V-VTR 140, 60 Hz
Ultimate vacuum 150 mbar (abs.) p.1 ↗
Rated voltage 230 / 400 V ± 10 % V p.2 ↗ 50 Hz
Rated voltage 220 / 380 V ± 10 % V p.2 ↗ 60 Hz
Motor rating 3,0 kW p.2 ↗ V-VTR 100, 50 Hz
Motor rating 4,0 kW p.2 ↗ V-VTR 140, 50 Hz
Motor rating 3,6 kW p.2 ↗ V-VTR 100, 60 Hz
Motor rating 4,8 kW p.2 ↗ V-VTR 140, 60 Hz
Current consumption 14,8 / 8,5 A p.2 ↗ V-VTR 140, 50 Hz
Current consumption 17,9 / 10,3 A p.2 ↗ V-VTR 140, 60 Hz
Motor efficiency 90,6 % p.2 ↗ V-VTR 140, 50 Hz
Motor efficiency 91,7 % p.2 ↗ V-VTR 140, 60 Hz
Speed 1450 min⁻¹ p.2 ↗ 50 Hz
Speed 1740 min⁻¹ p.2 ↗ 60 Hz
Mean sound pressure level 75 dB(A) p.2 ↗ V-VTR 100, 50 Hz, EN ISO 3744
Mean sound pressure level 75 dB(A) p.2 ↗ V-VTR 140, 50 Hz, EN ISO 3744
Mean sound pressure level 77 dB(A) p.2 ↗ V-VTR 100, 60 Hz, EN ISO 3744
Mean sound pressure level 78 dB(A) p.2 ↗ V-VTR 140, 60 Hz, EN ISO 3744
Weight 151 kg p.2 ↗ V-VTR 100
Weight 162 kg p.2 ↗ V-VTR 140
Protection class IP 55 p.1 ↗
Insulation class F p.1 ↗

Operating Limits

  • Ultimate vacuum (max. end vacuum): 150 mbar (abs.) p.1 ↗
  • Suction capacity range: 100 to 155 m³/h p.1 ↗
  • Rated voltage tolerance: ± 10 % p.2 ↗
  • Curve/table tolerance: ± 10 % p.2 ↗
  • Sound pressure level tolerance: ± 3 dB(A) p.2 ↗

Type Code Decoder

Position Token Meaning
1-6 p.1 ↗ V-VTR Series: dry-running rotary vane vacuum pump
field 2 p.1 ↗ 100 / 140 Size (nominal suction capacity class)
field 3 p.2 ↗ xx Motor/voltage variant code (Vx, Sx, Ux, Tx) selecting the Δ/Y winding voltages
field 4 p.2 ↗ Δ / Y Motor connection: delta or star

Modelos relacionados