Technical Data Sheet — C-VLR 1000 IE3 vacuum pump DE/EN)

Technical Reference Summary

Covered Models & Document Scope

Bomba de vacío de garras C-VLR 1000, compresión seca y sin contacto, con motores IE3; abarca variantes de funcionamiento a 50 Hz y 60 Hz

Technical Data

Parameter Value Condición
Suction capacity 950 m³/h p.2 ↗ C-VLR 1000, 50 Hz
Suction capacity 1140 m³/h p.2 ↗ C-VLR 1000, 60 Hz
Rated voltage 400 / 690 ± 10 % V p.2 ↗ C-VLR 1000, 50 Hz
Rated voltage 380 / 660 ± 10 % V p.2 ↗ C-VLR 1000, 60 Hz
Motor power 18,5 kW p.2 ↗ C-VLR 1000, 50 Hz
Motor power 22,0 kW p.2 ↗ C-VLR 1000, 60 Hz
Current drawn 34,0 / 19,7 A p.2 ↗ C-VLR 1000, 50 Hz
Current drawn 41,8 / 24,0 A p.2 ↗ C-VLR 1000, 60 Hz
Motor efficiency 92,4 % p.2 ↗ C-VLR 1000, 50 Hz
Motor efficiency 92,0 % p.2 ↗ C-VLR 1000, 60 Hz
Rotational speed 2945 rpm p.2 ↗ C-VLR 1000, 50 Hz
Rotational speed 3540 rpm p.2 ↗ C-VLR 1000, 60 Hz
Average noise level 82 dB(A) p.2 ↗ C-VLR 1000, 50 Hz, EN ISO 3744
Average noise level 83 dB(A) p.2 ↗ C-VLR 1000, 60 Hz, EN ISO 3744
Weight 757 kg p.2 ↗ C-VLR 1000, 50 Hz
Weight 755 kg p.2 ↗ C-VLR 1000, 60 Hz
Ultimate vacuum at continuous operation 200 mbar (abs.) p.1 ↗ C-VLR 1000
Protection rating IP 55 p.1 ↗ C-VLR 1000
Insulation class F p.1 ↗ C-VLR 1000

Operating Limits

  • Ultimate vacuum at continuous operation: 200 mbar (abs.) p.1 ↗
  • Protection rating: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗