Safety, improper use, disposal and service guidance
Overviewpp. 14-16
Gauge construction and functional description
Specpp. 17-20
Measurement ranges, accuracy and operating conditions
Specpp. 21-22
Dimensional drawing and pressure definitions
Specpp. 23-25
Correction factors for gases and notes
Procedurepp. 26-33
Mounting, electronics unit removal and optional accessories
Procedurepp. 34-35
Wiring and use with other controllers
Procedurepp. 36-42
Serial communication setup and commands
Procedurepp. 43-47
Startup procedure and display description
Specpp. 48-52
Interface parameters and command reference
Specpp. 53-55
Profibus configuration and data exchange
Procedurepp. 56-58
Setting and configuring switching functions
Procedurepp. 59-60
Removing the gauge from the system
Procedurepp. 61-63
Maintenance, repair and safety warnings
Procedurep. 64
Procedure for zero point calibration
Procedurepp. 65-66
Fault diagnosis and remedies
Procedurep. 67
Sensor replacement instructions
Orderingpp. 68-71
Ordering information for accessories and spare parts
pp. 72-73
Customer care contacts and book index
p. 15table, 9 rows
p. 68table, 5 rows
p. 14table, 36 rows
p. 18table, 31 rows
p. 20table, 13 rows
p. 41table, 14 rows
p. 47table, 11 rows
p. 22table, 3 rows
Table 1 Part Numbers
Part Number
Description
Without Display
FRG720KF25
FRG-720 Pirani/Bayard-Alpert combination full range gauge, single filament, NW 25KF flange.
FRG720CF35
FRG-720 Pirani/Bayard-Alpert combination full range gauge, single filament, DN40 CFF 2.75 flange.
With Display
FRG720KF25D
FRG-720 Pirani/Bayard-Alpert combination full range gauge, single filament, LCD display, NW 25KF flange.
FRG720CF35D
FRG-720 Pirani/Bayard-Alpert combination full range gauge, single filament, LCD display, DN 40 CFF 2.75 flange.
With Profibus interface and 2 switching functions
FRG720KF25SP
FRG-720 Pirani/Bayard-Alpert combination full range gauge, single filament, with setpoints and profibus, NW 25KF flange.
FRG720CF35SP
FRG-720 Pirani/Bayard-Alpert combination full range gauge, single filament, DN40 CFF 2.75 flange, Profibus.
Table 14 FRG-720 Accessories and Spare Parts
PART NUMBER
DESCRIPTION
FRG720BKE
Bakeout extension, FRG-720 Pirani/Bayard-Alpert combination full range gauge, 100 mm.
FRG720KF25RS
Replacement sensor, FRG-720 Pirani/Bayard-Alpert combination full range gauge, NW 25KF.
FRG720CF35RS
Replacement sensor, FRG-720 Pirani/Bayard-Alpert combination full range gauge, 2.75 in ConFlat Flange.
FRG720BFL
Baffle, FRG-720 Pirani/Bayard-Alpert combination full range gauge.
FRG720PWR
Power supply, FRG-720 full range gauge, 24 V DC, RS232C.
Содержание
Раздел
Страница
Technical Information
Product Description
15
Technical Specifications
17
FRG-720 Outline
21
Measurement Signal vs. Pressure
22
Gas Type Dependence
23
Installation
26
Vacuum Connection
26
Removing and Installing the Electronics Unit
28
Installing the Optional Extension
29
Using the Optional Baffle
31
Electrical Connection
34
Use With Agilent Vacuum Gauge Controller
34
Use With Other Controllers
35
Operation
43
Measuring Principle, Measuring Behavior
43
Putting the Gauge Into Operation
46
Degas
46
Display
47
RS232C Interface
48
Description of the Functions
48
Profibus Interface
53
Description of the Functions
53
Operating Parameters
54
Switching functions
56
Setting the Switching Functions
57
Deinstallation
59
Maintenance, Repair
61
Cleaning the Gauge
61
Adjusting the Gauge
62
Adjustment at Atmospheric Pressure
62
Zero Point Adjustment
64
Troubleshooting
65
What to Do in Case of Problems
65
Replacing the Sensor
67
Accessories and Spare Parts
68
Table 2 Technical Specifications (continued)
FRG-720 Specifications
Value
Power Supply
WARNING The gauge must only be connected to power supplies, instruments or control devices that conform to the requirements of a grounded extra-low voltage (SELV). The connection to the gauge has to be fused (Agilent controllers fulfill these requirements).
Operating voltage at the gauge
+24 VDC (+20 … +28 VDC) 1) ripple ≤2 Vpp
Power consumption
Standard
≤0.5 A
Degas
≤0.8 A
Emission start (<200 ms)
≤1.4 A
Power consumption
Standard gauge
≤16 W
Profibus gauge
≤18 W
Fuse necessary
1.25 AT
Sensor cable connection
Electrical connector
D-Sub,15-pin, male
Standard gauge
Cable for standard gauge
Analog values only Without degas function
4 conductors plus shielding
Analog values with degas function
5 conductors plus shielding
Analog values with degas function and RS232C interface
7 conductors plus shielding
Profibus gauge
depending on the functions used, max 15 conductors plus shielding
Cable for Profibus gauge
Max. cable length (supply voltage 24 V 1))
Analog and fieldbus operation
≤35 m, conductor cross-section 0.25 mm² ≤50 m, conductor cross-section 0.34 mm² ≤100 m, conductor cross-section 1.0 mm²
RS232C operation
≤30 m
Gauge identification
42 kΩ resistor between Pin 10 (sensor cable) and GND
Switching functions
Standard gauge
none
Profibus gauge
2 (setpoints A and B)
Adjustment range
1×10-9 mbar … 100 mbar
Relay contact rating
Setpoints adjustable via potentiometers (setpoints A and B), one floating, normally open relay contact per setpoint. Adjusting the setpoints via field bus is described in the corresponding bus sections.
Voltage
≤60 V
Current
≤0.5 ADC
1) Measured at sensor cable connector (consider the voltage drop as function of the sensor cable length).
Table 2 Technical Specifications (continued)
FRG-720 Specifications
Value
Weight
FRG720KF25, FRG720KF25D
≈285 g
FRG720CF35, FRG720CF35D
≈550 g
FRG720KF25SP
≈430 g
FRG720CF35SP
≈695 g
Ambiance
Admissible temperatures
Storage
–20 … +70 °C
Operation
0 … +50 °C
Bakeout
+150 °C (without electronics unit or with bakeout extension
Relative humidity (year's mean / during 60 days)
≤65 / 85% (no condensation)
Use
indoors only altitude up to 2000 m NN
Type of protection
IP 30
CAUTION Vacuum component. Inappropriate storage leads to an increase of the desorption rate and/or may result in mechanical damage of the product. Cover the vacuum ports of the product with protective lids or grease free aluminum foil. Do not exceed the admissible storage temperature range.
Internal data connection failure (red background illumination)
Function display: E, E., D, A, Ok, 5, 9, 8; Pressure display; Error display
Measurement Signal vs. Pressure
U [V]
p [mbar]
p [Pa]
p [Torr]
U
p
c
[V]
[mbar]
[Pa]
[Torr]
-0.125
p = 10^((U-7.75)/0.75+c), где p — давление, U — измерительный сигнал, c — константа (зависит от единицы давления)
Engineering Facts
13 facts · every claim linked to a page
Selection
The gauge covers a continuous measurement range of 5×10⁻¹⁰ to 1000 mbar, so it can serve both high-vacuum and rough-vacuum needs with one sensor.
Defines whether a single gauge can replace separate Pirani and BA heads across the whole process range.
Source
“5×10-10 … 1000 mbar continuous”
Operation
The hot cathode is automatically switched on only below 2.4×10⁻² mbar and off above 3.2×10⁻² mbar, protecting the filament from burnout at high pressure.
Confirms the gauge is safe to leave connected during venting and that no external interlock is needed for filament protection.
Source
“The hot cathode is switched on by the Pirani measurement system only below the switching threshold of 2.4×10-2 mbar (to prevent filament burn-out).”
Installation
The gauge must be powered from a grounded SELV supply and the connection must be fused, otherwise the installation is non-compliant.
Determines the power supply and fusing requirements for the electrical cabinet design.
Source
“The gauge must only be connected to power supplies, instruments or control devices that conform to the requirements of a grounded extra- low voltage (SELV).”
Installation
For KF-flanged versions a conductive metallic clamping ring is required to achieve the protective earth connection to the chamber.
Affects the choice of clamp hardware; a non-conductive ring would leave the gauge ungrounded and hazardous.
Source
“For gauges with KF connections, use a conductive metallic clamping ring.”
Installation
The sensor can be baked to 150 °C, but above 50 °C the electronics unit must be removed or a bakeout extension installed.
Dictates whether a bakeout extension must be ordered and how the gauge is mounted on a bakeable chamber.
Source
“At temperatures exceeding 50 °C, the electronics unit has to be removed or an extension has to be installed.”
Installation
The gauge may be mounted in any orientation, but horizontal to upright is preferred to keep condensates and particles out of the measuring chamber.
Guides physical placement on the chamber to avoid contamination-related measurement drift.
Source
“The gauge may be mounted in any orientation. To keep condensates and particles from getting into the measuring chamber preferably choose a horizontal to upright position.”
Cumplimiento
The gauge must not be operated with an Agilent Vacuum Gauge Controller and Profibus at the same time because data transmission errors may occur.
Prevents a wiring/architecture mistake when integrating the gauge into a controller plus fieldbus network.
Source
“The gauge must not be operated with a Agilent Vacuum Gauge Controller and Profibus at the same time.”
Installation
Maximum RS232C cable length is 30 m, while analog/fieldbus operation allows up to 100 m with 1.0 mm² conductors.
Sets the cable gauge and routing limits between the gauge and the control cabinet.
Source
“≤100 m, conductor cross-section 1.0 mm²”
Operation
A stabilization time of about 10 minutes must be allowed after power-on before readings meet the specified accuracy.
Defines the warm-up period to respect before using the gauge for process control or calibration checks.
Source
“Allow for a stabilizing time of approx. 10 min.”
Maintenance
Degas heats the electron collector grid to about 700 °C and terminates automatically after 3 minutes; it should only be run below 7.2×10⁻⁶ mbar.
Specifies the safe pressure window and duration for in-situ cleaning to avoid damage and unstable readings.
Source
“The degas process should be run at pressures below 7.2×10-6 mbar”
Performance
For gases other than air/N2 the indicated pressure must be corrected with a calibration factor, e.g. 0.8 for Ar and 5.9 for He.
Required to interpret readings correctly when the process gas is not nitrogen or air.
Source
“peff = C × indicated pressure”
Safety
Clamps must not be opened while the vacuum system is pressurized above 1 bar, as released parts and escaping process gases can cause injury.
Defines the venting/interlock procedure for maintenance work on the gauge port.
Source
“Do not open any clamps while the vacuum system is pressurized.”
Maintenance
Gauge failures due to contamination or wear, and expendable parts such as the filament, are excluded from warranty.
Affects spare-parts planning and the decision to add a baffle in contaminating processes.
Source
“Gauge failures due to contamination or wear and tear as well as expendable parts (e.g. filament) are not covered by the warranty.”