Unistat P520 Temperature Control System Datasheet

Contenido

  1. Overview p. 1
    Introduces the Unistat P520 temperature control system
  2. Spec p. 2
    Technical data according to DIN 12876 standard
  3. p. 2 table, 12 rows
  4. p. 1 table, 30 rows

Technical data according to DIN 12876

ParameterValue
Delivery at 2,0 bar46 l/min
Delivery at 2,5 bar32 l/min
Pump connectionM30x1,5 male
max. permissible kin. viscosity50 mm²/s
min. filling capacity5,1 l
Filling capacity expansion tank17 l
Overall dimensions WxDxH **1290x900x1400 mm
Power supply factory configured (3 Phase)400V 3~ 50Hz
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.:1.0/24

** Please respect space requirements. See operating conditions at www.huber-online.com

Unistat P520 Technical data according to DIN 12876

ParameterValue
Order-No.1072.0023.01
Operating temperature range-55...250 °C
Temperature stability at -10°C0,01 K
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
Sensor external connectionPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Alarm messageoptic, acoustic, relay
Safety classificationIII / FL
Heating power6 kW
Cooling power with Thermooil at 250°C6 kW
Cooling power with Thermooil at 200°C6 kW
Cooling power with Thermooil at 100°C6 kW
Cooling power with Ethanol at 0°C6 kW
Cooling power with Ethanol at -20°C4,2 kW
Cooling power with Ethanol at -40°C1,5 kW
Cooling power with Ethanol at -50°C0,65 kW
Refrigeration machineair-cooled, natural refrigerant
Refrigerant (ASHRAE, GHS)R-1270 (A3, H220)
Global Warming Potential (GWP)0
UN-numberUN 3358
Circulation pumpMK pump
max. delivery82 l/min
max. delivery pressure3 bar
Delivery at 0,5 bar75 l/min
Delivery at 1,0 bar66 l/min
Delivery at 1,5 bar57 l/min

Engineering Facts

14 facts · every claim linked to a page
Selection

The unit is a refrigerated heating circulator with an air-cooled condenser, so it rejects heat to ambient air and needs adequate room ventilation.

Air-cooled machines require sufficient ambient airflow and room heat load planning at selection and installation.

Source
“Refrigerated Heating Circulator with air-cooled cooling machine and optical level indicator.”
Selection

The P-models are specifically intended for high-pressure-drop circuits, so they suit flow-through chemistry or semiconductor applications.

Confirms the pump head is matched to restrictive external circuits rather than low-pressure baths.

Source
“Unistat „P“ Models: Circulating pumps with a high discharge pressure for applications with high pressure drops, e.g. in the Flow-Through chemistry or in the Semicon industry.”
Installation

The pump connection is M30x1.5 male, so mating hoses or fittings must match this thread.

Wrong thread on hoses or adapters prevents leak-free connection and commissioning.

Source
“Pump connection M30x1,5 male”
Installation

The unit is factory-configured for 400 V three-phase 50 Hz supply, so site power must match before delivery.

Three-phase supply and correct voltage/frequency must be confirmed at the installation site.

Source
“Power supply factory configured (3 Phase) 400V 3~ 50Hz”
Installation

Three-phase devices below 63 A are supplied with cable but without a plug, so the customer must provide the site plug.

Electrical hook-up planning must include a suitable plug and connection by qualified personnel.

Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Installation

Voltage and frequency tolerances are linked: ±5% voltage only with ±2% frequency, and certain combinations are not allowed.

Site power quality must be checked against the combined tolerance rule to avoid invalid supply conditions.

Source
“-5% voltage and +2% frequency -> not allowed!”
Safety

Leakage current exceeds 3.5 mA, so protective earthing and RCD selection must account for this.

Affects earth connection and residual-current device selection during electrical installation.

Source
“Attention: leakage current > 3,5mA”
Safety

The refrigerant is R-1270 (A3, H220), a flammable natural refrigerant, so ignition sources and ventilation must be considered.

Flammable refrigerant classification drives room ventilation and ignition-source restrictions.

Source
“R-1270 (A3, H220)”
Operation

Cooling capacity drops as ambient temperature rises, so performance ratings assume 20 °C room temperature.

Selection must derate cooling capacity for actual ambient conditions in the lab.

Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Operation

The unit is rated for ambient temperatures from 5 °C to 40 °C, so operation outside this range is not permitted.

Room climate must be verified before installation and during operation.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Operation

The minimum filling capacity is 5.1 l and the expansion tank holds 17 l, so the external circuit volume must be planned accordingly.

Prevents underfilling and overflow when sizing the external loop and heat transfer fluid charge.

Source
“min. filling capacity 5,1 l Filling capacity expansion tank 17 l”
Operation

The maximum permissible kinematic viscosity of the heat transfer fluid is 50 mm²/s, so fluid choice must respect this limit.

Wrong fluid viscosity can overload the pump and reduce circulation performance.

Source
“max. permissible kin. viscosity 50 mm²/s”
Cumplimiento

The equipment is EMC class A group 1, so it is intended for industrial environments and may cause interference in residential areas.

Determines suitability of the installation location and possible EMC mitigation measures.

Source
“Classification (disturbance) to EN55011: Class A, Group 1”
Maintenance

The unit has an optical level indicator and a magnetic-coupled stainless steel pump, so level checks and pump inspection are part of routine care.

Informs maintenance access and spare-part planning for the circulation pump.

Source
“Magnetic coupled circulation pump made of stainless steel.”