Unistat T305 HT Technical Data

Contenido

  1. Overview p. 1
    Product name and general introduction to the Unistat T305 HT unit
  2. Spec p. 2
    Technical data according to DIN 12876 for the unit
  3. p. 1 table, 34 rows

Technical data according to DIN 12876

ParameterValue
Order-No.1003.0049.01
Operating temperature range65... 300 °C
Temperature stability at 70°C0,01 K
temperature set point / display5,7" colour Touchscreen
Resolution of display0,01 K
Internal temperature sensorPt100
External sensorPt100
Interface digitalEthernet, USB (Host u. Device), RS232
digital inputECS ONE
digital outputPOKO ONE
Alarm messageoptic, acoustic, relay
Safety classificationIII / FL
Heating power at 240V3 kW
Heating power at 230V3 kW
Heating power at 220V3 kW
Heating power at 208V2,7 kW
Heating power at 200V2,5 kW
Cooling power at 300°C3,2 kW
Cooling power at 200°C2,3 kW
Cooling power at 100°C0,6 kW
Circulation pump: max. delivery45 l/min
max. delivery pressure0,9 bar
Pump connectionM24x1,5 male
max. permissible kin. viscosity50 mm²/s
min. filling capacity3,5 l
Filling capacity expansion tank4,5 l
Overall dimensions WxDxH **425x250x631 mm
Net weight42 kg
Power supply requirement200-240V 1~/2~ 50/60Hz
Pressure equipment categoryArt. 4.3 PED
Degree of ProtectionIP20
min. ambient temperature5 °C
max. ambient temperature40 °C
from Serial-No.1.0/24

** Overall dimensions WxDxH

Engineering Facts

14 facts · every claim linked to a page
Selection

The unit covers 65 to 300 °C, so it is only suitable for high-temperature closed-loop or open-bath duty, not for sub-ambient work.

Defines the process window and excludes applications requiring cooling below 65 °C.

Source
“Operating temperature range 65... 300 °C”
Installation

The electrical supply must be 200–240 V single- or two-phase at 50/60 Hz, so the site must provide the correct branch circuit and plug configuration.

Determines site power availability, cable/plug selection and branch protection before ordering.

Source
“Power supply requirement 200-240V 1~/2~ 50/60Hz”
Installation

External branch circuit protection to UL 489 is mandatory, so the installer must provide a listed breaker ahead of the unit.

Affects electrical panel design and compliance sign-off during installation.

Source
“External branch circuit protection according to UL 489 required.”
Installation

Single- and two-phase units are delivered with a country-specific plug only if specified at order, so the plug type must be stated on the purchase order.

Prevents a missing or wrong plug on delivery and avoids site rework.

Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Installation

The pump connection is M24x1.5 male with Y-bore and DIN 3863 ball-socket hoses, so mating hoses and fittings must match this standard.

Ensures correct hose/fitting procurement and leak-free connection at commissioning.

Source
“Pump connection M24x1,5 male”
Installation

The note specifies Y-bore pump connections to DIN 3863 and ball-socket/sleeve-nut hoses to DIN 3863/3870, so non-matching fittings will not seal.

Defines the exact mating geometry for pipework and flexible hoses.

Source
“Pump connections: Bore shape Y (60°) according to DIN 3863, pipework/flexible tempering hoses: Ball socket according to DIN 3863, sleeve nut according to DIN 3870.”
Operation

The maximum permissible kinematic viscosity is 50 mm²/s, so the thermofluid must be selected to stay below this at the lowest operating temperature.

Prevents pump overload and poor circulation when choosing the heat-transfer fluid.

Source
“max. permissible kin. viscosity 50 mm²/s”
Operation

Minimum filling capacity is 3.5 l and the expansion tank holds 4.5 l, so the loop volume and expansion allowance must be checked before filling.

Ensures sufficient fluid volume and expansion space to avoid cavitation or overflow.

Source
“min. filling capacity 3,5 l”
Installation

The unit is rated IP20, so it must be installed in a dry indoor location protected from water ingress.

Restricts installation environment and rules out washdown or outdoor siting.

Source
“Degree of Protection IP20”
Installation

Ambient temperature must stay between 5 and 40 °C, so the room HVAC and placement near heat sources must be considered.

Affects room selection and derating/performance expectations at site.

Source
“min. ambient temperature 5 °C max. ambient temperature 40 °C”
Performance

Cooling capacity drops from 3.2 kW at 300 °C to 0.6 kW at 100 °C, so heat-removal capability must be sized against the actual process temperature.

Prevents oversizing expectations and ensures the cooler can handle the process heat load at low end of range.

Source
“Cooling power at 100°C 0,6 kW”
Performance

The pump delivers up to 45 l/min at 0.9 bar, so external loop pressure drop must be checked against this curve.

Determines whether the circulation pump can serve the intended external circuit.

Source
“max. delivery 45 l/min”
Cumplimiento

The unit is classified III / FL to DIN 12876, so it is suitable for flammable liquids only under the conditions of that classification.

Governs whether the unit may be used with flammable thermofluids and what safety measures apply.

Source
“Safety classification III / FL”
Cumplimiento

The pressure equipment is categorized under Art. 4.3 PED, so the PED assessment route and documentation must be confirmed for the installation.

Affects CE/PED compliance paperwork and acceptance at site.

Source
“Pressure equipment category Art. 4.3 PED”