Induztr
Resumen técnico Visor de documentos Modelos relacionados

384 C225E014A

Technical Reference Summary

Covered Models & Document Scope

Sistema de microensayo magnético Microservo serie MMT, unidades principales MMT-500NV-10, MMT-250NV-10, MMT-101NV-10, MMT-101NV-2, MMT-11NV-2, utilizadas en combinación con el controlador 4830

Technical Data

Parameter Value Condición
Test force Max. ± 500 N p.7 ↗ MMT-500NV-10
Test force Max. ± 250 N p.7 ↗ MMT-250NV-10
Test force Max. ± 100 N p.7 ↗ MMT-101NV-10
Test force Max. ± 10 N p.7 ↗ MMT-101NV-2, MMT-11NV-2
Piston stroke Max. ± 10 mm p.7 ↗ MMT-500NV-10, MMT-250NV-10, MMT-101NV-10
Piston stroke Max. ± 2 mm p.7 ↗ MMT-101NV-2, MMT-11NV-2
Frequency Max. 100 Hz p.7 ↗ MMT-500NV-10, MMT-250NV-10, MMT-101NV-10
Frequency Max. 60 Hz p.7 ↗ MMT-101NV-2, MMT-11NV-2
Load cell (standard accessory) ± 500 N p.7 ↗ MMT-500NV-10
Load cell (standard accessory) ± 250 N p.7 ↗ MMT-250NV-10
Load cell (standard accessory) ± 100 N p.7 ↗ MMT-101NV-10
Load cell (standard accessory) ± 10 N p.7 ↗ MMT-101NV-2, MMT-11NV-2
Total weight approx. 150 kg p.7 ↗ MMT-500NV-10
Total weight approx. 120 kg p.7 ↗ MMT-250NV-10
Total weight approx. 100 kg p.7 ↗ MMT-101NV-10
Total weight approx. 80 kg p.7 ↗ MMT-101NV-2, MMT-11NV-2
Power supply 1ø 100 V 1 kVA p.7 ↗ MMT-500NV-10, MMT-250NV-10, MMT-101NV-10
Power supply 1ø 100 V 500 VA p.7 ↗ MMT-101NV-2, MMT-11NV-2
Thermostatic chamber temperature range Room temperature + 10 to 300 °C p.6 ↗ test device
Tensile test force 100 N p.6 ↗ Tensile Test Jig
3-point bending test force 100 N p.6 ↗ 3-Point Bending Test Jig
4-point bending test force 100 N p.6 ↗ 4-Point Bending Test Jig
Key pressing test force 100 N p.6 ↗ Key Pressing Test Jig
Compression test force 100 N p.6 ↗ Compression Test Jig

Operating Limits

  • Max test force: ±500 N p.7 ↗
  • Max piston stroke: ±10 mm p.7 ↗
  • Max frequency: 100 Hz p.7 ↗
  • Thermostatic chamber temperature range: Room temperature +10 to 300°C p.6 ↗

Type Code Decoder

Position Token Meaning
1-3 p.7 ↗ MMT Series: Microservo Magnetic Micro Testing System
4-6 p.7 ↗ 500 / 250 / 101 / 11 Test force size: 500 N, 250 N, 100 N, 10 N
7-8 p.7 ↗ NV Model variant
9-10 p.7 ↗ 10 / 2 Stroke/frequency variant: 10 = max ±10 mm, max 100 Hz; 2 = max ±2 mm, max 60 Hz

Ordering Data

Ordering Code Part No. Variant / Code Aplica a Note
MMT-500NV-10 p.7 ↗ 348-20803-00 Max. ±500 N, max ±10 mm, max 100 Hz, approx. 150 kg, 1ø 100 V 1 kVA
MMT-250NV-10 p.7 ↗ 348-20802-00 Max. ±250 N, max ±10 mm, max 100 Hz, approx. 120 kg, 1ø 100 V 1 kVA
MMT-101NV-10 p.7 ↗ 348-20801-00 Max. ±100 N, max ±10 mm, max 100 Hz, approx. 100 kg, 1ø 100 V 1 kVA
MMT-101NV-2 p.7 ↗ 348-20801-01 Max. ±10 N, max ±2 mm, max 60 Hz, approx. 80 kg, 1ø 100 V 500 VA
MMT-11NV-2 p.7 ↗ 348-20800-01 Max. ±10 N, max ±2 mm, max 60 Hz, approx. 80 kg, 1ø 100 V 500 VA

Modelos relacionados