Agilent Triple Quadrupole LC/MS User Guide

Contenido

  1. pp. 2-4
    Legal notices, guide contents, and technical support contacts
  2. pp. 5-6
    Full document table of contents listing
  3. Overview pp. 9-23
    Instrument views, calibrant delivery, magnets, and status indicators
  4. Overview pp. 24-28
    AJS ESI, APCI, MMI, and Nanospray source descriptions
  5. Procedure pp. 29-46
    Autotune, checktune, scheduling, advanced and diagnostic tune
  6. Procedure pp. 47-74
    Startup, shutdown, acquisition software, methods, samples, worklists
  7. Procedure pp. 75-98
    Routine and periodic maintenance tasks and pump oil replacement
  8. Procedure pp. 99-126
    Nebulizer, capillary, calibrant flush, multiplier, valve, corona maintenance
  9. Procedure pp. 127-136
    Maintenance procedures for ESI, AJS ESI, APCI, and MMI sources
  10. Quality pp. 137-145
    Regulatory compliance, EMC, WEEE, and end-of-life information
  11. p. 146
    Agilent website contact reference
  12. p. 31 table, 4 rows
  13. p. 104 table, 4 rows

Table 2 Tuning mixes

SourceTuning mixPart Number
ESIESI-L Low Concentration Tuning MixG1969-85000
AJS ESIESI-L Low Concentration Tuning MixG1969-85000
MMIMMI-L Low Concentration Tuning MixG1969-85020
APCIAPCI-L Low Concentration Tuning MixG1969-85010

Table 1 Correct needle position

NebulizerDistance
Microflow Nebulizer Assembly0.003 inch
ES Tested Nebulizer0.000 (flush)
Tested ESI Nebulizer Assembly (older style)0.003 inch
Tested APCI Nebulizer Assembly0.000 (flush)

Engineering Facts

14 facts · every claim linked to a page
Safety

The instrument contains magnets that can interfere with pacemakers and other active implanted medical devices, so users with AIMDs must follow manufacturer guidance.

Site safety planning and personnel restrictions must account for strong magnets near the door and front cover.

Source
“This product contains magnets that may affect the functioning of pacemakers, implanted heart defibrillators, or other active implanted medical devices”
Selection

The AJS ESI source uses super-heated nitrogen thermal gradient focusing and can improve sensitivity about five-fold for many small-molecule compounds.

Source selection should weigh the sensitivity gain of AJS ESI against ESI for small-molecule work.

Source
“improves sensitivity 5x or more for many small-molecule compounds that undergo electrospray ionization.”
Selection

The Multimode source can run ESI only, APCI only, or mixed ESI/APCI and supports LC flow rates up to 2 mL/min.

Choosing MMI enables broad compound coverage and compatibility with higher-flow LC methods.

Source
“Simultaneous ESI and APCI capability and high LC flow rate compatibility (up to 2 mL/min)”
Operation

A checktune verifies peak width and mass axis before acquisition, while an autotune is only needed after preventive maintenance or if checktune fails.

This defines the routine tuning workflow and avoids unnecessary autotune downtime.

Source
“An autotune only needs to run after preventative maintenance or if there is a problem with checktune.”
Selection

The tuning mix must match the installed source, with distinct part numbers for ESI, AJS ESI, MMI, and APCI.

Ordering the wrong tuning mix for a source leads to miscalibration and mass assignment errors.

Source
“Use Table 2 to select the correct tuning mix for the source installed.”
Operation

Requesting tune control locks the LC/TQ so that no sample run or worklist can be started during tuning.

Operators must release tune control before scheduling analytical runs.

Source
“When tune has control of the LC/TQ instrument, a single sample run or a worklist cannot be started.”
Safety

The system must always be vented before pressing the power button to prevent instrument damage.

Shutdown procedures must include a full vent step to protect the turbo and vacuum components.

Source
“To prevent instrument damage, always vent the system before pressing the power button.”
Safety

The spray shield and spray chamber components are likely to be hot and must not be touched.

Maintenance and shutdown planning must include cool-down and burn protection.

Source
“Do not touch the spray shield and related spray chamber components. They are likely to be hot.”
Operation

When not acquiring data, the LC stream should be switched away from the MS ion source to waste.

This protects the source from unnecessary sample and solvent exposure during equilibration.

Source
“When not acquiring data, switch the direction of the LC stream away from the MS ion source and to waste.”
Maintenance

The calibrant bottle should only be snug, because over-tightening can prevent pressurization and cause evaporation of the tuning mix.

Correct bottle installation avoids leaks and preserves tuning mix concentration.

Source
“The bottle only needs to be snug. Do not over-tighten the bottle.”
Maintenance

Tuning mixes are not interchangeable, and failing to change the mix when the source or inlet changes can cause miscalibration and mass assignment errors.

Source changeover procedures must include replacing the tuning mix to maintain calibration.

Source
“The tuning mixes are not interchangeable.”
Maintenance

Rough pump oil should be checked quarterly and replaced if it is dark or contains suspended particles.

Scheduled oil inspection prevents pump wear and vacuum instability.

Source
“If the pump oil is dark or full of suspended particles, replace it.”
Installation

Nitrogen gas filters have a maximum operating pressure of 250 PSIG, maximum temperature of 100 °C, and maximum flow of 8 liters per minute.

Gas supply and plumbing must be rated within these limits to avoid filter failure.

Source
“Maximum operating pressure is 250 PSIG.”
Installation

Stainless steel tubing requires purifiers with stainless steel fittings, since brass fittings increase the risk of cross-threading.

Correct fitting material selection prevents leaks and damaged connections during installation.

Source
“Using brass fittings with stainless steel tubing increases the risk of cross-threading.”

Modelos relacionados